Users Guide

Table Of Contents
Table 56. Virtual Disk Specifications for PERC Hardware Controllers (continued)
Virtual Disk
Specification
PERC
H840
Adapte
r
PERC
FD33xD
/
FD33xS
PERC
H730P
MX
PERC
H745P
MX
PERC
H345
Front/
Adapter
PERC
H755
Front/
Adapter
PERC
H755N
Front
PERC
H745
Front/
Adapter
PERC
H755 MX
Maximum
Number of
Physical Disks
in a RAID 50
256 256 256 256 NA 256 256 256 256
Minimum
Number of
Physical Disks
dxe cthat can
be
Concatenated
NA NA NA NA NA NA NA NA NA
Minimum
Number of
Physical Disks
in a RAID 0
1 1 1 1 1 1 1 1 1
Minimum
Number of
Physical Disks
in a RAID 1
2 2 2 2 2 2 2 2 2
Minimum
Number of
Physical Disks
in a RAID 5
3 3 3 3 NA 3 3 3 3
Minimum
Number of
Physical Disks
in a RAID 10
4 4 4 4 4 4 4 4 4
Minimum
Number of
Physical Disks
in a RAID 50
6 6 6 6 NA 6 6 6 6
Maximum
Number of
Physical Disks
in a RAID 6
32 32 32 32 NA 32 32 32 32
Maximum
Number of
Physical Disks
in a RAID 60
256 256 256 256 NA 256 256 256 256
Minimum
Number of
Physical Disks
in a RAID 6
4 4 4 4 NA 4 4 4 4
Minimum
Number of
Physical Disks
in a RAID 60
8 8 8 8 NA 8 8 8 8
NOTE: When performing an Auto Configure RAID0 operation on PERC H830 hardware controller, the maximum number of
physical disks supported is 192.
NOTE: RAID 1 VD on SWRAID controller will enumerate for the attribute Stripe Element Size as NA.
Supported Features 181