CLI Guide

Table Of Contents
Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem
Pwrmonitoring
Use the omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring command to configure
power consumption information.
The following table displays the valid parameters for the command:
Table 54. Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring
name=value pair 1 name=value pair 2 Description
index=<n> NA Number of the probe or probe index
(must specify).
config=probe warnthresh=settodefault Sets the minimum and maximum warning
thresholds values to default.
warnthresh=<n > Sets a value for the warning threshold.
unit=watt | btuphr
watt: Displays the unit in Watts.
btuphr: Displays the unit in BTU/hr.
config=resetreading type=energy | peakpower
energy: Resets the system energy
reading.
peakpower: Resets the system peak
power.
NOTE: Power monitoring requires license to configure the power budget information. If the appropriate license is not
installed or has expired, the system displays an error message. For more information, see Dell License Manager at
dell.com/openmanagemanuals.
Default warning thresholds
NOTE: Sensor managing capabilities vary across systems.
To set both the upper and lower power consumption probe warning threshold values to the recommended default value, type:
omconfig chassis pwrmonitoring config=probe index=0 warnthresh=settodefault
or
omconfig mainsystem pwrmonitoring config=probe index=0 warnthresh=settodefault
You cannot default one value and set another. If you default the minimum warning threshold value, you are also selecting the
default value for the maximum warning threshold value.
Specify A Value For Warning Thresholds
If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the probe
you are configuring and the warning threshold value. Configure the values to display either in BTU/hr or Watts. In the following
example, the probe that is being configured is probe 4:
omconfig chassis pwrmonitoring config=probe index=4 warnthresh=325 unit=watt
or
omconfig mainsystem pwrmonitoring config=probe index=4 warnthresh=325 unit=btuphr
Omconfig Managing Components Using The Instrumentation Service
81