CLI Guide
Table Of Contents
- Dell EMC OpenManage Command Line Interface Guide Version 10.1.0.0
- Contents
- Introduction
- Using The omhelp Command
- omreport Viewing System Status Using The Instrumentation Service
- Conventions for parameter tables
- Command summary of the omreport command
- Help With The omreport Command
- omreport modularenclosure
- omreport about
- Omreport Chassis Or Omreport Mainsystem Commands
- Chassis management
- Omreport chassis acswitch or omreport mainsystem acswitch
- Omreport Chassis Batteries Or Omreport Mainsystem Batteries
- Omreport Chassis Bios Or Omreport Mainsystem Bios
- Omreport chassis biossetup or omreport mainsystem biossetup
- BIOS setup groups
- Omreport Chassis Currents Or Omreport Mainsystem Currents
- Omreport chassis fans or omreport mainsystem fans
- Omreport Chassis Firmware Or Omreport Mainsystem Firmware
- Omreport Chassis Frontpanel Or Omreport Mainsystem Frontpanel
- Omreport Chassis Fru Or Omreport Mainsystem Fru
- Omreport chassis hwperformance or omreport mainsystem hwperformance
- Omreport Chassis Info Or Omreport Mainsystem Info
- Omreport Chassis Intrusion
- Omreport Chassis Leds Or Omreport Mainsystem Leds
- Omreport Chassis Memory Or Omreport Mainsystem Memory
- Omreport chassis nics or omreport mainsystem nics
- Omreport Chassis Ports Or omreport Mainsystem Ports
- Omreport Chassis Processors Or Omreport Mainsystem Processors
- Omreport chassis pwrmanagement or omreport mainsystem pwrmanagement
- Omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring
- Omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
- Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
- Omreport Chassis Removableflashmedia Or Omreport Mainsystem Removableflashmedia
- Omreport Chassis Slots Or Omreport Mainsystem Slots
- Omreport chassis temps or Omreport mainsystem temps
- Omreport Chassis Volts Or Omreport Mainsystem Volts
- Omreport Licenses
- Omreport System Commands Or Omreport Servermodule Commands
- Omreport System Or Omreport Servermodule
- Commands for viewing logs
- Omreport System Alertaction Or Omreport Servermodule Alertaction
- Omreport System Assetinfo Or Omreport Servermodule Assetinfo
- Omreport system events or omreport servermodule events
- Omreport System Events Type Or Omreport Servermodule Events Type
- Omreport System snmptrapdest Or Omreport Servermodule snmptrapdest
- Omreport System Operatingsystem Or Omreport Servermodule Operatingsystem
- Omreport System Pedestinations Or Omreport Servermodule Pedestinations
- Omreport System Platformevents Or Omreport Servermodule Platformevents
- Omreport System Recovery Or Omreport Servermodule Recovery
- Omreport System Shutdown Or Omreport Servermodule Shutdown
- Omreport System Summary Or Omreport Servermodule Summary
- Omreport System Thrmshutdown Or Omreport Servermodule Thrmshutdown
- Omreport System Version Or Omreport Servermodule Version
- Omreport Preferences Commands
- Omconfig Managing Components Using The Instrumentation Service
- Conventions for parameter tables
- omconfig Command Summary
- Help With The Omconfig Command
- Omconfig About
- Omconfig Chassis Or Omconfig Mainsystem
- Omconfig Chassis Biossetup Or Omconfig Mainsystem Biossetup
- Omconfig Chassis Currents Or Omconfig Mainsystem Currents
- Omconfig Chassis Fans Or Omconfig Mainsystem Fans
- Omconfig chassis frontpanel or omconfig mainsystem frontpanel
- Omconfig Chassis Info Or Omconfig Mainsystem Info
- Omconfig Chassis Leds Or Omconfig Mainsystem Leds
- Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode
- Omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement
- Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring
- Omconfig chassis remoteaccess or omconfig mainsystem remoteaccess
- Omconfig Chassis Temps Or Omconfig Mainsystem Temps
- Omconfig Chassis Volts Or Omconfig Mainsystem Volts
- Omconfig Preferences
- Omconfig System Or Omconfig Servermodule
- Omconfig System Alertaction Or Omconfig Servermodule Alertaction
- Commands for clearing logs
- Omconfig system pedestinations or omconfig servermodule pedestinations
- Omconfig system platformevents or omconfig servermodule platformevents
- Omconfig system snmptraptest or omconfig servermodule snmptraptest
- Omconfig System Events Or Omconfig Servermodule Events
- Omconfig System Webserver Or Omconfig Servermodule Webserver
- Omconfig System Recovery Or Omconfig Servermodule Recovery
- Omconfig System Shutdown Or Omconfig Servermodule Shutdown
- Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown
- Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership Values
- Adding acquisition information
- Adding depreciation information
- Adding extended warranty information
- Adding lease information
- Adding maintenance information
- Adding outsource information
- Adding owner information
- Adding service contract information
- Adding support information
- Adding system information
- Adding warranty information
- Using The Storage Management Service
- Omreport storage commands
- Omconfig storage commands
- Omconfig Physical Disk Commands
- Omconfig Blink Physical Disk
- Omconfig Unblink Physical Disk
- Omconfig Prepare To Remove Physical Disk
- Omconfig Instant Erase Secured Physical Disk
- Omconfig Cryptographic Erase Secured Physical Disk
- Omconfig Initialize Physical Disk
- Omconfig Offline Physical Disk
- Omconfig Online Physical Disk
- Omconfig Assign Global Hot Spare
- Omconfig Available Spare
- Omconfig Rebuild Physical Disk
- Omconfig Cancel Rebuild Physical Disk
- Omconfig Cancel Replace Member
- Omconfig Clear Physical Disk
- Omconfig cancel clear physical disk
- Omconfig Enable Device Write Cache
- Omconfig Disable Device Write Cache
- Omconfig Export Reliability Log
- Omconfig Export Telemetry Log
- Omconfig Convert RAID To Non-RAID
- Omconfig Convert Non-RAID To RAID
- Omconfig Set array disk cache
- Omconfig virtual disk commands
- Omconfig Check Consistency
- Omconfig Pause Check Consistency
- Omconfig cancel check consistency
- Omconfig Resume Check Consistency
- Omconfig blink virtual disk
- Omconfig Unblink Virtual Disk
- Omconfig Initialize Virtual Disk
- Omconfig Fast Initialize Virtual Disk
- Omconfig Slow Initialize Virtualize Disk
- Omconfig cancel initialize virtual disk
- Omconfig cancel background initialize
- Omconfig Assign Dedicated Hot Spare
- Omconfig Delete Virtual Disk
- Omconfig reconfiguring virtual disks
- Omconfig Secure Virtual Disk
- Omconfig Clear Virtual Disk Bad Blocks
- Omconfig Change Virtual Disk Policy
- Omconfig Replace Member Virtual Disk
- Omconfig Rename Virtual Disk
- Omconfig controller commands
- Omconfig Rescan Controller
- Omconfig Enable Controller Alarm
- Omconfig Disable Controller Alarm
- Omconfig Quiet Controller Alarm
- omconfig Test Controller Alarm
- Omconfig Reset Controller Configuration
- omconfig Create Virtual Disk
- Omconfig Set Controller Rebuild Rate
- omconfig Change Controller Properties
- Omconfig Discard Preserved Cache
- Omconfig Create Encryption Key
- Omconfig Change Encryption Key
- Omconfig Delete Encryption Key
- Omconfig Set Background Initialization Rate
- Omconfig Set Reconstruct Rate
- Omconfig Set Check Consistency Rate
- Omconfig Export The Controller Log
- Omconfig Import Secure Foreign Configuration
- Omconfig Import Foreign Configuration
- Omconfig Import Or Recover Foreign Configuration
- Omconfig Clear Foreign Configuration
- Omconfig physical disk power management
- Omconfig set controller mode
- Omconfig autoconfigure RAID0
- Omconfig Set Patrol Read Mode
- Omconfig Start Patrol Read
- Omconfig Stop Patrol Read
- Omconfig Create Cachecade
- Omconfig Enable LKM Controller
- Omconfig Rekey LKM Controller
- Omconfig Convert Multiple RAID To Non-RAID
- Omconfig Convert Multiple Non-RAID To RAID
- Omconfig Enclosure Commands
- Omconfig Enable Enclosure Alarm
- Omconfig Disable Enclosure Alarm
- Omconfig Set Enclosure Asset Tag
- Omconfig Set Enclosure Asset Name
- Omconfig Set Temperature Probe Thresholds
- Omconfig Reset Temperature Probe Thresholds
- Omconfig Set All Temperature Probe Thresholds
- Omconfig Reset All Temperature Probe Thresholds
- Omconfig Blink
- Omconfig Battery Commands
- Omconfig Global Commands
- Omconfig Connector Commands
- Omconfig cachecade commands
- Omconfig NVMe adapter configuration commands
- Omconfig Physical Disk Commands
- Working With CLI Command Results
- Identifying the series of your Dell EMC PowerEdge servers
Table 51. Valid Parameters Of Omconfig Chassis Leds Or Omconfig Mainsystem Leds (continued)
name=value pair 1 name=value pair 2 Description
led=identify flash=off | on time-out=<n> Sets the chassis identification LED to off
or on. Set the time-out value for the LED
to flash to a number of seconds.
Omconfig Chassis Memorymode Or Omconfig Mainsystem
Memorymode
Use the omconfig chassis memorymode or omconfig mainsystem memorymode command to specify the
redundancy mode to use for the system memory in case of memory errors.
Redundant memory enables a system to switch to other available memory modules if unacceptable errors are detected in
the modules that the system is currently using. The omconfig chassis memorymode or omconfig mainsystem
memorymode command allows you to disable redundancy; when you disable redundancy, you instruct the system not to
switch to other available memory modules when the memory module the system is using begins to encounter errors. To enable
redundancy, choose among spare, mirror, raid, and DDDC.
Spare mode disables a bank of system memory in which a correctable memory event is detected, enables the spare bank, and
copies all the data from the original bank to the spare bank. Spare bank requires at least three banks of identical memory; the
operating system does not recognize the spare bank.
Mirror mode switches to a redundant copy of memory when an uncorrectable memory event is detected. After switching to the
mirrored memory, the system does not switch back to the original system memory until the next reboot. The operating system
does not recognize half of the installed system memory in this mode.
RAID mode provides an extra level of memory checking and error recovery at the expense of some memory capacity.
The DDDC mode enables double device data correction. This ensures data availability after hard failure of x4 DRAM.
NOTE:
This command is applicable only on systems prior to PowerEdge YX2X systems. On PowerEdge YX2X systems,
memorymode is grouped under Memory Settings of the BIOS setup group. For more information, see BIOS Setup Groups
on PowerEdge YX2X Systems.
To configure the attribute on systems prior to PowerEdge YX2X, see the following table. The table displays the valid parameters
for the command.
Table 52. Valid Parameters Of Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode
name=value pair 1 Description
index=<n> Number of the chassis where the memory module resides (the
default is chassis 0, the main system chassis).
redundancy=spare | mirror | disabled | raid5 | dddc
spare: Disables the memory module that has a correctable
memory event and copies the failing module’s data to a spare
bank.
mirror: Switches the systems to a mirrored copy of the
memory if the failing module has an uncorrectable memory
event. In the mirror mode, the operating system does not
switch back to the original module until the system reboot.
disabled: Indicates that the system is not to use other
available memory modules if uncorrectable memory events are
detected.
raid5: Method of system memory configuration. This is
logically similar to the RAID-5 mode used in hard drive
storage systems. This memory mode provides an extra level of
memory checking and error recovery at the expense of some
memory capacity. The RAID mode supported is RAID level 5
striping with rotational parity.
dddc: The dddc mode enables double device data correction.
This ensures data availability after hard failure of x4 DRAM.
78 Omconfig Managing Components Using The Instrumentation Service