CLI Guide

Table Of Contents
Table 42. omconfig Command Level 1, Level 2, and Level 3 (continued)
Command
Level 1
Command Level
2
Command Level
3
User
Privilege
Required
Use
recovery P, A Determines in advance how the system responds to a hung
operating system.
shutdown A Allows the administrator to select from several options
when shutting down the system.
thrmshutdown A Sets the severity level at which a thermal event triggers a
system shutdown.
webserver A Starts or stops the Web server.
chassis or
mainsystem
biossetup A Configures the behavior of specific system components
controlled by the BIOS.
fans P, A
Configures fan probe warning thresholds to the default or
a specific value.
NOTE: You cannot change threshold values on
embedded server management (ESM3) and Dell
PowerEdge x8xx systems.
frontpanel A Configures the Power button, Non-Masking Interrupt
(NMI) button, encryption access, and LCD display of the
system.
info P, A Allows you to set an initial value, or to edit the value of the
asset tag or chassis name.
leds P, A Specifies when to flash a chassis fault LED or chassis
identification LED, and allows you to clear the LED for the
system's hard drive.
memorymode A Enables or disables the spare bank, mirroring, raid, and
Double Device Data Correction (DDDC) memory modes,
and also specify which mode to use.
pwrmanagement P, A Allows you to choose between maximum power, economy,
and optimized performance of the system.
pwrmonitoring P, A Configures power consumption information and thresholds.
remoteaccess A Configures remote access information.
temps P, A
Sets warning threshold values to the default or a specific
value.
NOTE: You cannot change threshold values on ESM3
and PowerEdge x8xx systems.
volts P, A
Sets warning threshold values to the default or a specific
value.
NOTE: You cannot change threshold values on ESM3
and PowerEdge x8xx systems.
storage For more information, see Using The Storage Management
Service.
Omconfig Managing Components Using The Instrumentation Service 57