Table 204. Omconfig Set All Temperature Probe Thresholds (continued)
In this syntax, n is a user-specified alphanumeric string.
Example to Set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on
controller 1, to 10 and 40 degree Celsius.
Example for SAS
controllers
omconfig storage enclosure action=setalltempprobes controller=1
enclosure=2:3 minwarn=10 maxwarn=40
Omconfig Reset All Temperature Probe Thresholds
Table 205. Omconfig Reset All Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default value for
all temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Syntax
omconfig storage enclosure action=resetalltempprobes controller=id
enclosure=<ENCLOSUREID>, where id is the controller ID. The <ENCLOSUREID> variable
specifies the enclosure.
In this syntax, n is a user-specified alphanumeric string.
Example to Reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on
controller 1.
Example for SAS
controllers
omconfig storage enclosure action= resetalltempprobes controller=1
enclosure=2:3
Omconfig Blink
Table 206. omconfig Blink
Description Blinks the light-emitting diodes (LEDs) on the enclosure.
Syntax
omconfig storage enclosure action=blink controller=id
enclosure=<ENCLOSUREID>, where id is the controller ID. The <ENCLOSUREID> variable
specifies the enclosure.
Example to Blink the LEDs for enclosure 3 attached to connector 2 on controller 1.
Example for SAS
controllers
omconfig storage enclosure action=blink controller=1 enclosure=2:3
Example for SCSI,
SATA, and ATA
controllers
omconfig storage enclosure action=blink controller=1 enclosure=2
Omconfig Battery Commands
The following table displays the omconfig command syntax required to execute battery tasks.
180