CLI Guide

Table Of Contents
Omconfig Cancel Rebuild Physical Disk
Table 121. omconfig Cancel Rebuild Physical Disk
Description
Cancels a rebuild that is in progress. If you cancel a rebuild,
the virtual disk remains in a degraded state. For more
information about Cancel Rebuild Physical Disk, see the Dell
EMC OpenManage Online Help.
Syntax
omconfig storage pdisk action=cancelrebuild
controller=id pdisk=<PDISKID>, where id is the
controller ID. The <PDISKID> variable specifies the physical
disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller
IDs and then type omreport storage pdisk
controller=ID to display the IDs for the physical disks
attached to the controller.
Example to Cancel the rebuild of physical disk 3 on connector 0 of
controller 1. On a SAS controller, the physical disk resides in
enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=cancelrebuild
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=cancelrebuild
controller=1 pdisk=0:2:3
Omconfig Cancel Replace Member
Table 122. omconfig Cancel Replace Member
Description
Cancels a replace member operation.
Syntax
omconfig storage pdisk
action=cancelreplacemember controller=id
pdisk=<PDISKID>, where id is the controller ID. The
<PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller
IDs and then type omreport storage pdisk
controller=ID to display the IDs for the physical disks
attached to the controller.
Example to Cancel replace member operation on disk 0:0:1 which is
connected to controller 0
Example
omconfig storage pdisk
action=cancelreplacemember controller=0
pdisk=0:0:1
146 Omconfig storage commands