CLI Guide

Table Of Contents
Table 76. Valid Parameters Of System Shutdown (continued)
name=value pair Description
NOTE: This command osfirst=false is not available on YX3X and later systems. By default,
on YX3X and later systems, the operating system shuts down before turning off the server during
a remote shutdown.
Example Shutdown Commands
To set the shutdown action to reboot, type:
omconfig system shutdown action=reboot
or
omconfig servermodule shutdown action=reboot
To bypass operating system shutdown before the system is powered off, type:
omconfig system shutdown action=reboot osfirst=false
or
omconfig servermodule shutdown action=reboot osfirst=false
NOTE:
The parameter osfirst=false is not available on YX3X and later systems. By default, on YX3X and later
systems, the operating system shuts down before turning off the server during a remote shutdown.
Omconfig System Thrmshutdown Or Omconfig Servermodule
Thrmshutdown
Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to configure
a thermal shutdown action. You can configure the system for a thermal shutdown when a temperature probe detects a
temperature probe warning or failure event.
The following table displays the valid parameters for the command:
Table 77. Valid Parameters Of Thermal Shutdown
name=value pair Description
severity=disabled | warning | failure
disabled: Disable thermal shutdown. An administrator must intervene.
warning: Perform a shutdown when a temperature warning event is detected.
A warning event occurs when any temperature probe inside a chassis reads a
temperature (in degree Celsius) that exceeds the maximum temperature warning
threshold value.
failure: Perform a shutdown when a temperature failure event is detected.
A failure event occurs when any temperature probe inside a chassis reads a
temperature (in degree Celsius) that exceeds the maximum temperature failure
threshold value.
Example Thermal Shutdown Commands
To trigger a thermal shutdown when a temperature probe detects a failure event, type:
omconfig system thrmshutdown severity=failure
Omconfig Managing Components Using The Instrumentation Service
115