Table 70. Valid Parameters Of Omconfig System Platformevents (continued)
Event Name Description
event=redunlost Sets action or enables or disables alert generation when the system fans and/or
power supplies become inoperative, resulting in a lost or a no redundant components
working condition for that component.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail Sets actions when a power consumption probe detects a failure value.
event=tempwarn Sets action or enables or disables alert generation when a temperature probe detects
that the temperature is approaching the maximum high or low limits.
event=removableflashmediapresent Sets actions that Server Administrator performs when the system detects a
removable flash media.
event=removableflashmediawarn Sets actions that Server Administrator performs when a removable flash media
warning is displayed.
event=removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails.
event=tempfail Sets action or enables or disables alert generation when a temperature probe detects
that the temperature is either too high or low for proper operation.
event=voltfail Sets action or enables or disables alert generation when a voltage probe detects that
the voltage is too low for proper operation.
event=intdualsdcardcritical Sets actions that Server Administrator performs when an internal dual SD card critical
event occurs.
event=intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual SD card
warning is displayed.
event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual SD card is not
available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal
dual SD card is lost.
event=watchdogasr Enables or disables alert generation configured by the ASR when the system has hung
or is not responding.
Omconfig system snmptraptest or omconfig servermodule
snmptraptest
Use the omconfig system snmptraptest or omconfig servermodule snmptraptest command to send the snmp
test trap to the destination address if Server Administrator SNMP component is configured in the configuration file.
The following table displays the valid parameters for the command:
Table 71. Parameters For Alert Action Command
Action Description
dest=<ipv4 address |
ipv6 address | fqdn>
Send the test trap to the destination IP address.
NOTE: This feature is not supported on VMware ESXi.
Omconfig System Events Or Omconfig Servermodule Events
Use the omconfig system events or omconfig servermodule events command to enable and disable SNMP traps
for the components on your system.
Omconfig Managing Components Using The Instrumentation Service
111