CLI Guide

Table Of Contents
Table 69. Parameters For Alert Action Command (continued)
Action Description
action=powerreduction Reduces the processor speed until the power consumption comes down and reaches below the
warning threshold. If the system power consumption remains below the warning threshold, increase
the processor speed.
NOTE: This action is applicable only for PowerEdge Rack and Tower systems earlier than 11th
generation of PowerEdge systems.
action=reboot Forces the operating system to shut down and initiates system startup, performs BIOS checks, and
reloads the operating system.
Components and events of platform events
The following table lists the components and the events for which you can set platform events. Components are listed in
alphabetical order, except that warning events always precede failure events for a component.
Table 70. Valid Parameters Of Omconfig System Platformevents
Event Name Description
alertsenable=true | false
true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter alerts.
NOTE: This setting is independent of the individual platform event filter alert
settings. For a platform event filter to generate an alert, both the individual alert
and the global event alert are enabled.
event=batterywarn Sets action or enables or disables alert generation when a battery device detects that
the battery is pending a failure condition.
event=batteryfail Sets action or enables or disables alert generation when a battery device detects that
the battery has failed.
event=discretevolt Sets action or enables or disables alert generation when a discrete voltage probe
detects that the voltage is too low for proper operation.
event=fanfail Sets action or enables or disables alert generation when a fan probe detects that the
fan is running too slow or not at all.
event=hardwarelogfail Enables or disables alert generation when a hardware log detects a failure value.
event=intrusion Sets action or enables or disables alert generation when a chassis is opened.
event=powerwarn Sets action or enables or disables alert generation when a power device probe detects
that the power supply, voltage regulator module, or DC to DC converter is pending a
failure condition.
event=powerabsent Sets action or enables or disables alert generation when a processor probe detects
that the power supply is absent.
event=powerfail Sets action or enables or disables alert generation when a power device probe detects
that the power supply, voltage regulator module, or DC to DC converter has failed.
event=processorwarn Sets action or enables or disables alert generation when a processor probe detects
that the processor is running at less than peak performance or speed.
event=processorfail Sets action or enables or disables alert generation when a processor probe detects
that the processor has failed.
event=processorabsent Sets action or enables or disables alert generation when a processor probe detects
that the processor is absent.
event=redundegrad Sets action or enables or disables alert generation when the system fans and/or
power supplies become inoperative, resulting in less than full redundancy for that
component.
110 Omconfig Managing Components Using The Instrumentation Service