CLI Guide

Table Of Contents
Table 67. Valid Parameters Of Events for Alert Actions (continued)
Event Name Description
event=tempwarn Sets actions when a temperature probe detects a warning value.
event=tempfail Sets actions when a temperature probe detects a failure value.
event=voltwarn Sets actions when a voltage probe detects a warning value.
event=voltfail Sets actions when a voltage probe detects a failure value.
event=watchdogasr Sets actions that Server Administrator performs on the next system startup after a
watchdog Automatic System Recovery (ASR) is performed for a hung operating system.
event=removableflashmediapres
ent
Sets actions that Server Administrator performs when the system detects a removable flash
media.
event=removableflashmediarem
oved
Sets actions that Server Administrator performs when a removable flash media is removed.
event=removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails.
event=storagesyswarn Sets actions when a storage system detects a warning value.
event=storagesysfail Sets actions when a storage system detects a failure value.
event=storagectrlwarn Sets actions when a storage controller detects a warning value.
event=storagectrlfail Sets actions when a storage controller detects a failure value.
event=pdiskwarn Sets actions when a physical disk detects a warning value.
event=pdiskfail Sets actions when a physical disk detects a failure value.
event=vdiskwarn Sets actions when a virtual disk detects a warning value.
event=vdiskfail Sets actions when a virtual disk detects a failure value.
event=enclosurewarn Sets actions when an enclosure detects a warning value.
event=enclosurefail Sets actions when an enclosure detects a failure value.
event=storagectrlbatterywarn
Sets actions when a storage controller battery detects a warning value.
event=storagectrlbatteryfail
Sets actions when a storage controller battery detects a failure value.
Example Set Alert Action Commands
The following are examples of valid example commands. For each successful command issued, the following message is
displayed:
Alert action(s) configured successfully.
Example Current Probe Actions
To disable system console alert if a current probe detects a warning event, type:
omconfig system alertaction event=currentwarn alert=false
or
omconfig servermodule alertaction event=currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail broadcast=true
Omconfig Managing Components Using The Instrumentation Service
107