CLI Guide

Table Of Contents
Table 66. Valid Parameters of Alert Actions For Warning and Failure Events (continued)
Alert Action Setting Description
false: Disables the system's console alert.
broadcast=true | false
true: Enables a message or alert to broadcast to all users
who have an active terminal (or Remote Desktop) session
(Windows) or to operators that have an active shell on the
local system (Linux.)
false: Disables alert broadcasts.
clearall=true Clears all actions for this event.
execappath=<string>
Sets the fully qualified path and file name of the application
you want to execute in case of an event for the component
described in this window.
NOTE: On Linux systems, user or user groups upgraded
to administrator or administrator groups cannot configure
this alert action setting.
execapp=false Disables the executable application.
Components and events for alert actions
The following table provides the events for which you can set alert actions. Components are listed in alphabetical order, except
that warning events always precede failure events for a component.
Table 67. Valid Parameters Of Events for Alert Actions
Event Name Description
event=batterywarn Sets actions when a battery probe detects a warning value.
event=batteryfail Sets actions when a battery probe detects a failure value.
event=fanwarn Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull Sets actions when a hardware log is full.
event=intrusion Sets actions when a chassis intrusion event is detected.
event=memprefail Sets actions when a memory probe detects a prefailure value.
event=memfail Sets actions when a memory probe detects a failure value.
event=systempeakpower Sets actions when a power consumption probe detects peak power value.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail Sets actions when a power consumption probe detects a failure value.
event=powersupply Sets actions when a power supply probe detects a failure value.
event=powersupplywarn Sets actions when a power supply probe detects a warning value.
event=processorwarn Sets actions when a processor probe detects a warning value.
event=processorfail Sets actions when a processor probe detects a failure value.
event=redundegrad Sets actions when a redundant component becomes inoperative, resulting in less than full
redundancy for that component.
event=redunlost Sets actions when one or more redundant components become inoperative, resulting in a
lost or a "no redundant components working" condition for that component.
106 Omconfig Managing Components Using The Instrumentation Service