Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1588. Channel Severity (continued)
Access Read-only
Table 1589. Channel Termination
Name
channelTermination
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5
Description Identifies the type of SCSI termination on this channel. Termination is required for
proper operation of this channel.
Possible values:
1: Wide Termination (16 bit)
2: Narrow Termination (8 bit)
3: Not Terminated
Syntax Integer
Access Read-only
Table 1590. Channel SCSI ID
Name
channelSCSIID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.6
Description Identifies the SCSI ID of the controller to which the channel belongs.
Syntax Integer
Access Read-only
Table 1591. Channel Roll-Up Status
Name
channelRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7
Description Identifies the severity of the channel state. This is the combined status of the channel
and its components.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only
Table 1592. Channel Component Status
Name
channelComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8
Description The status of the channel itself without the propagation of any contained component
status.
Possible values:
1: Other
354 Storage Management Group