Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1458. BMC LAN Interface Default Gateway Address (continued)
Syntax IpAddress
Access Read-only
Table 1459. BMC LAN Interface MAC Address
Name
bmcLANInterfaceMACAddress
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.12
Description Defines the MAC address of the BMC LAN interface.
Syntax DellMACAddress
Access Read-only
Table 1460. BMC LAN Interface Alert Community Name
Name
bmcLANInterfaceAlertCommunityName
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13
Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN
interface.
Syntax DisplayString (SIZE (0..32))
Access Read-only
Baseboard Management Controller Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 1461. Baseboard Management Controller
Variable Name:DellBMCSerialConnectionModeCapabilities
Data Type:Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values Meaning of Data Value
-- none(0)
No mode capabilities.
modemBasic(1)
BMC serial interface supports Modem
Basic mode.
modemPPP(2)
BMC serial interface supports Modem
Point to Point Protocol (PPP) mode.
modemTerminal(4)
BMC serial interface supports Modem
Terminal mode.
directBasic(8)
BMC serial interface supports Direct
Basic mode.
directPPP(16)
BMC serial interface supports Direct
PPP mode.
directTerminal(32)
BMC serial interface supports Direct
Terminal mode.
Table 1462. BMC Serial Connection Mode Settings
Variable
Name:DellBMCSerialConnectionModeSettingsDellBMCSerialConnec
tionModeCapabilities
326 Server Administrator Group