Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1012. Memory Device Type (continued)
deviceTypeIs3DRAM(1
4)
Device type is 3DRAM.
deviceTypeIsSDRAM(1
5)
Device type is SDRAM.
deviceTypeIsSGRAM(1
6)
Device type is SGRAM.
deviceTypeIsRDRAM(1
7)
Device type is RDRAM.
deviceTypeIsDDR(18)
Device type is DDR.
deviceTypeIsDDR2(19
)
Device type is DDR2.
deviceTypeIsDDR2FBD
IMM(20)
Device type is DDR2 FB-DIMM.
deviceTypeIsDDR3(24
)
Device type is DDR3.
deviceTypeIsFBD2(25
)
Device type is FBD2.
deviceTypeIsDDR4(26
)
Device type is DDR4.
Table 1013. Memory Device Type Details
Variable Name:DellMemoryDeviceTypeDetails
Data Type:Integer
Possible Data Values Meaning of Data Value
deviceTypeDetailIsO
ther(2)
The detailed device type is not one of the following:
deviceTypeDetailIsU
nknown(4)
The detailed device type is unknown.
deviceTypeDetailIsF
astPaged (8)
The detailed device type is fast paged.
deviceTypeDetailIsS
taticColum n(16)
The detailed device type is static column.
deviceTypeDetailIsP
seudoStati c(32)
The detailed device type is pseudo-static.
deviceTypeDetailIsR
AMBUS(64)
The detailed device type is RAMBUS.
deviceTypeDetailIsS
ynchronous (128)
The detailed device type is synchronous.
deviceTypeDetailIsC
MOS(256)
The detailed device type is CMOS.
deviceTypeDetailIsE
DO(512)
The detailed device type is EDO.
deviceTypeDetailIsW
indowDRAM (1024)
The detailed device type is Window DRAM.
deviceTypeDetailIsC
acheDRAM (2048)
The detailed device type is Cache DRAM.
230 Server Administrator Group