Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1007. Cache Device ECC Type (continued)
deviceTypeIsATrackB
all(4)
Device type is a track ball.
deviceTypeIsATrackP
oint(5)
Device type is a track point.
deviceTypeIsAGlideP
oint(6)
Device type is a glide point.
deviceTypeIsATouchP
ad(7)
Device type is a touch pad.
Table 1008. Cache Device Associativity
Variable Name:DellCacheDeviceAssociativity
Data Type:Integer
Possible Data Values Meaning of Data Value
deviceAssociativity
IsOther(1)
Device associativity is not one of the following:
deviceAssociativity
IsUnknown(2)
Device associativity is unknown.
deviceAssociativity
IsDirectMapped(3)
Device is direct mapped.
deviceAssociativity
IsTwoWaySetAssociat
ive(4)
Device is two-way set associative.
deviceAssociativity
IsFourWaySetAssocia
tive(5)
Device is four-way set associative.
deviceAssociativity
IsFullyAssociative
(6)
Device is fully associative.
deviceAssociativity
IsEightWaySetAssoci
ative(7)
Device is eight-way set associative.
deviceAssociativity
IsSixteenWaySetAsso
ciative(8)
Device is sixteen-way set associative.
deviceAssociativity
Is12WaySetAssociati
ve(9)
Device is 12-way Set-Associative.
deviceAssociativity
Is24WaySetAssociati
ve(10)
Device is 24-way Set-Associative.
deviceAssociativity
Is32WaySetAssociati
ve(11)
Device is 32-way Set-Associative.
deviceAssociativity
Is48WaySetAssociati
ve(12)
Device is 48-way Set-Associative.
deviceAssociativity
Is64WaySetAssociati
ve(13)
Device is 64-way Set-Associative.