Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 904. Generic Device System Slot Index Reference
Name
genericDeviceSystemSlotIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.6
Description Defines the index of the system slot into which this generic device is plugged.
Syntax DellObjectRange
Access Read-only
Table 905. Generic Device Type
Name
genericDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.7
Description Defines the type of the generic device.
Syntax DellGenericDeviceType (See Generic Device Type)
Access Read-only
Table 906. Generic Device Name
Name
genericDeviceName
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8
Description Defines the name of the generic device.
Syntax DellString
Access Read-only
PCI Device Table
Table 907. PCI Device Table
Name
pCIDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.80
Description Defines the PCI Device Detail Table.
Syntax SEQUENCE OF PCIDeviceTableEntry
Access Not accessible
Table 908. PCI Device Table Entry
Name
pCIDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1
Description Defines the PCI Device Table entry.
Syntax PCIDeviceTableEntry
Access Not accessible
Index
pCIDevicechassisIndex
,
pCIDeviceIndex
Server Administrator Group 199