Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 694. Memory Device Port State Capabilities (continued)
Access Read-only
Table 695. Memory Device Port State Settings
Name
memoryDevicePortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4
Description Defines the state and settings of the memory device port.
Syntax DellStateSettings
Access Read-only
Table 696. Memory Device Port Status
Name
memoryDevicePortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.5
Description Defines the status of the memory device port.
Syntax DellStatus
Access Read-only
Table 697. Memory Device Port Security State
Name
memoryDevicePortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6
Description Defines the security settings of the memory device port.
Syntax DellPortSecurityState
Access Read-only
Table 698. Memory Device Port Connector Type
Name
memoryDevicePortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7
Description Defines the connector type of the memory device port.
Syntax DellMemoryDevicePortConnectorType (See Memory Device Port Connector Types)
Access Read-only
Table 699. Memory Device Port Name
Name
memoryDevicePortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8
Description Defines the name of the memory device port.
Syntax DellString
Access Read-only
Table 700. Memory Device Port BIOS Connector Type
Name
memoryDevicePortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.9
Description Defines the BIOS connector type of the memory device port.
Syntax DellGenericPortConnectorType
158 Server Administrator Group