Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
● Serial Port Table
● Universal Serial Bus (USB) Port Table
Pointing Port Table
Table 657. Pointing Port Table
Name
pointingPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.10
Description Defines the Pointing Port Table.
Syntax IntegerPointingPortTableEntry
Access Not accessible
Table 658. Pointing Port Table Entry
Name
pointingPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1
Description Defines the Pointing Port Table entry.
Syntax PointingPortTableEntry
Access Not accessible
Index
pointingPortchassisIndex
,
pointingPortIndex
Table 659. Pointing Port Chassis Index
Name
pointingPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 660. Pointing Port Index
Name
pointingPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.2
Description Defines the index of the pointing ports in this chassis.
Syntax DellObjectRange
Access Read-only
Table 661. Pointing Port State Capabilities
Name
pointingPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.3
Description Defines the capabilities of the pointing port.
Syntax DellStateCapabilities
Server Administrator Group 151