Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 651. Remote Flash BIOS Last BIOS Date Name (continued)
Description Defines the date of the last BIOS update.
Syntax DellDateName
Access Read-only
Table 652. Remote Flash BIOS Completion Code
Name
remoteFlashBIOSCompletionCode
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7
Description Defines the completion code of the last BIOS update.
Syntax DellRemoteFlashBIOSCompletionCode (Remote Flash BIOS Completion Code)
Access Read-only
Table 653. Remote Flash BIOS Minimum Contiguous Memory
Name
remoteFlashBIOSMinimumContiguousMemory
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.8
Description Defines the minimum size of contiguous memory required for remote BIOS update in
kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only
Remote Flash BIOS Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 654. Remote Flash BIOS State Capabilities Unique
Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The remote flash BIOS’s capabilities are unknown.
enableCapable(2)
The remote flash BIOS can be disabled (offline, a binary 0
value) or enabled (online, a binary 1 value).
notReadyCapable(4)
The remote flash BIOS can be set to indicate not ready.
cancelCapable(8)
Flash of BIOS can be canceled.
enableAndCancelCapable(10)
Flash of BIOS can be enabled or canceled.
Table 655. Remote Flash BIOS State Settings
Variable Name: DellRemoteFlashBIOSStateSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The remote flash BIOS’s capabilities are unknown.
enabled(2)
The remote flash BIOS update is disabled (offline, a binary 0
value) or enabled (online, a binary 1 value).
notReady(4)
The remote flash BIOS’s state is not ready.
Server Administrator Group 149