Release Notes

Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
connected with two redundant EMMs, but both are
listed under Connector 0.
71919 SAS controllers On YX4X generation of PowerEdge servers when
connected with two SAS 12Gbps controller in Slot4 &
Slot5 and each controllers are connected with separate
MD1400 enclosure, with two redundant cable i.e. EMM0
& EMM1, then with redundant EMM both enclosures
are listed for EMM0 & EMM1, but physical disks are
not displayed for EMM1. Slot-4 SAS 12Gbps controller
is connected with two redundant EMMs Here both
EMMs are listed under Connector 0, and for EMM0
physical Disk is listed and for EMM1 no physical disks
are listed. Slot-5 SAS 12Gbps controller is connected
with single EMM (ie.EMM1) Here one EMM0 is listed
under Connector 0, and for EMM1 physical Disk are
listed.
Not available
76259 Dedicated hot-
spare
EMMI alert description for Dedicated hot-spare
assigned physical disk should contain meaningful alert
description instead of the statement, This alert is
provided for informational purposes.
Not available
94666 Non-RAID drives For Non-RAID drives attached to SWRAID controller
enumerates for virtual Disk layout as Non-RAID.
Whereas on Storage Management GUI, when you click
on virtual disk name the physical drives does not display
as Non-RAID.
Not available
96670 sfcbd-watchdog On systems running VMware operating systems if the
sfcbd-watchdog is stopped abruptly before completion
of the SNMP traps for storage task is logged.
Semaphore leak is observed.
Run the sfcbd-watchdog until
SNMP traps for storage task is
completed.
97151 Negotiated speed Full view of Physical Disk Page in Server Administrator
GUI, the negotiated speed for a 6Gbps drive capable
speed is intermittently shown as 12Gbps.
Not available
94842 storelibIR Storage Management carries SHA1 signed library
(storelibIR) in the current release.
Not available
104975 Fan speed In storage management, Fan speed changes will not
update dynamically.
Data manager service restart
will update the latest fan
speed.
106970 Change controller
mode
After change controller mode operation is performed,
two alerts that are generated have the same alert ID
and description.
Not available
Not available Controller
information
If the controller name is not displayed in the alert
message, check the controller information for mapping
the controller ID and controller name.
Not available
103891 PSU removal Duplicate alerts for power supply removal are displayed
while enclosure power supply cable is removed.
Not available
103962 EMM removal
alerts
The Storage Management displays the removal and
insertion alerts intermittently on EMM for HBA
controllers during physical drive hot-plug-out and hot-
plug-in.
RECOMMENDATION: Minimum of six seconds gap is
required between any hot-plug in or out operations.
Not available
21