Reference Guide

Table Of Contents
Event ID 2075
Description Copy of data completed from physical disk % 2 to physical disk % 1.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is provided for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2060
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID 2076
Description Virtual disk Check Consistency failed.
Severity Critical / Failure / Error
Cause and Action Cause: AA physical disk included in the virtual disk failed or there is an error in the parity information. A
failed physical disk can cause errors in parity information.
Action: Replace the failed physical disk. You can identify which disk has failed by locating the disk that
has a red X for its status. Rebuild the physical disk. When finished, restart the check consistency
operation.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID 2077
Description
Virtual disk format failed.
Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk failed.
Action: Replace the failed physical disk. You can identify which physical disk has failed by locating the
disk that has a red X for its status. Rebuild the physical disk. When finished, restart the virtual disk format
operation.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID 2079
Description
Virtual disk initialization failed.
68 Storage Management Message Reference