Reference Guide

Table Of Contents
Drive Bay state: <drive bay state>
Severity Informational
Cause A driver bay sensor in the specified system detected that the system cover was opened while the system
was operating. The sensor location, chassis location, previous state, and driver bay state information is
provided.
Event ID 1259
Description
Drive Bay intrusion detected Sensor location: <Location in drive bay>
Drive bay location: <Name of drive bay>
Previous state was: <State>
Drive Bay state: <drive bay state>
Severity Informational
Cause A chassis intrusion sensor in the specified system detected that the system cover was opened while the
system was operating. The sensor location, chassis location, previous state, and chassis intrusion state
information is provided.
Event ID 1261
Description
Drive Bay Intrusion Detected Extended Sensor location: <Location in drive
bay>
Drive bay location: <Name of drive bay>
Previous state was: <State>
Drive Bay state: <drive bay state>
Severity Critical
Cause A Drive Bay intrusion has been detected for extended period of time the system cover was opened while
the system was operating. The sensor location, chassis location, previous state, and chassis intrusion
state information is provided.
Redundancy Unit Messages
Redundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for
example, are so important for preventing damage or disruption of a computer system that a chassis may have extra fans or
power supplies installed. Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when
the primary fan has failed. Redundancy is normal when the intended number of critical components are operating. Redundancy is
degraded when a component fails but others are still operating. Redundancy is lost when the number of components functioning
falls below the redundancy threshold. Lists the redundancy unit messages.
The number of devices required for full redundancy is provided as part of the message, when applicable, for the redundancy unit
and the platform. For details on redundancy computation, see the respective platform documentation.
Event ID 1300
Description
Redundancy sensor has failed Redundancy unit: <Redundancy Location in
chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
38 Server Management Messages