Table 12. Memory Events (continued)
Event Message Severity Cause
Memory Spared redundancy
lost.
Critical This event is generated when
redundancy is lost in a spared memory
configuration.
Memory Spared redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier
is regained in a spared memory
configuration.
Memory RAID is redundant.
Information This event is generated when the
memory redundancy mode has change to
RAID redundant.
Memory RAID redundancy is
lost. Check memory device at
location(s) <DIMM number>.
Critical This event is generated when
redundancy is lost in a RAID-configured
memory configuration.
Memory RAID redundancy is
degraded. Check memory device
at location(s) <DIMM number
>.
Warning This event is generated when there is
a memory failure in a RAID-configured
memory configuration.
Memory is not redundant.
Information This event is generated when the
memory redundancy mode has change to
nonredundant.
Memory mirror is redundant.
Information This event is generated when the
memory redundancy mode has change to
mirror redundant.
Memory mirror redundancy is
lost. Check memory device at
location(s) <DIMM number>.
Critical This event is generated when
redundancy is lost in a mirror-configured
memory configuration.
Memory mirror redundancy is
degraded. Check memory device
at location <DIMM number >.
Warning This event is generated when there is
a memory failure in a mirror-configured
memory configuration.
Memory spare is redundant.
Information This event is generated when the
memory redundancy mode has change to
spare redundant.
Memory spare redundancy is
lost. Check memory device at
location <DIMM number>.
Critical This event is generated when
redundancy is lost in a sparer-configured
memory configuration.
Memory spare redundancy is
degraded. Check memory device
at location <DIMM number>.
Warning This event is generated when there is
a memory failure in a spare-configured
memory configuration.
Hardware Log Sensor Events
The hardware logs provide hardware status messages to the system management software. On particular systems, the
subsequent hardware messages are not displayed when the log is full. These messages provide status and warning messages
when the logs are full.
Table 13. Hardware Log Sensor Events
Event Message Severity Cause
Log full detected.
Critical This event is generated when the SEL
device detects that only one entry can
be added to the SEL before it is full.
System Event Log Messages for IPMI Systems 203