Reference Guide

Table Of Contents
Event ID 2360
Description A user has discarded data from the controller cache.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID 2361
Description Physical disk(s) that are part of a virtual disk have been removed while the system was shut down. This
removal was discovered during system start-up.
Severity Warning
Cause and Action Cause: This alert is for informational purposes.
Action: None.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
753
Event ID 2362
Description
Physical disk(s) have been removed from a virtual disk. The virtual disk is in Failed state during the next
system reboot.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID 2364
Description
All virtual disks are missing from the controller. This situation was discovered during system start-up.
Severity Warning
Cause and Action Cause: This alert is for informational purposes.
Storage Management Message Reference 151