Reference Guide

Table Of Contents
Local Response Agent (LRA) Number: 2101
SNMP Trap
Numbers
1154
Event ID 2338
Description The controller has recovered cached data from the BBU.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2339
Description
The factory default settings have been restored.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID 2340
Description
The BGI completed with uncorrectable errors.
Severity Critical / Failure / Error
Cause and Action Cause: The BGI task encountered errors that cannot be corrected. The virtual disk contains physical disks
that have unusable disk space or disk errors that cannot be corrected.
Action: Replace the physical disk that contains the disk errors. Review other alert messages to identify
the physical disk that has errors. If the virtual disk is redundant, you can replace the physical disk and
continue using the virtual disk. If the virtual disk is non-redundant, you may need to recreate the virtual
disk after replacing the physical disk. After replacing the physical disk, run Check Consistency to
check the data.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
144 Storage Management Message Reference