Reference Guide

Table Of Contents
SNMP Trap
Numbers
854
Event ID 2300
Description The enclosure is unstable.
Severity Critical / Failure / Error
Cause and Action Cause: The controller is not receiving a consistent response from the enclosure. There could be a
firmware problem or an invalid cabling configuration. If the cables are too long, they degrade the signal.
Action: Power down all enclosures attached to the system and reboot the system. If the problem
persists, upgrade the firmware to the latest supported version. You can download the most current
version of the driver and firmware from the support site. Make sure the cable configuration is valid. See
the hardware documentation for valid cabling configurations.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID 2301
Description
The enclosure has a hardware error.
Severity Critical / Failure / Error
Cause and Action Cause: The enclosure or an enclosure component is in a Failed or Degraded state.
Action: Check the health of the enclosure and its components. Replace any hardware that is in a Failed
state. See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID 2302
Description
The enclosure is not responding.
Severity Critical / Failure / Error
Cause and Action Cause: The enclosure or an enclosure component is in a Failed or Degraded state.
Action: Check the health of the enclosure and its components. Replace any hardware that is in a Failed
state. See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Storage Management Message Reference 133