Table 127. omconfig Export Reliability Log (continued)
controller=ID to display the IDs for the physical disks
attached to the controller.
NOTE: The <filename> is optional. If <filename> is not
present, a default filename is assigned.
NOTE: Depending on the PCIe SSD or
NVMe device the log file name will
be PCIeSSD_<device name>_<timestamp>.log or
NVMe_<device name>_<timestamp>.log where the
<device name> is the name of the device and timestamp
is month, day, hour, minute and second during which the
command is executed.
Example to Export log on physical disk 3 on connector 0 of controller 1.
On a SAS controller, the physical disk resides in enclosure 2.
Example for SAS controllers
omconfig storage pdisk action=exportlog
controller=1 pdisk=0:2:3
Omconfig Convert RAID To Non-RAID
Table 128. Omconfig Convert RAID To Non-RAID
Description
Converts RAID to non-RAID on a physical disk.
Syntax
omconfig storage pdisk
action=convertraidtononraid controller=id
pdisk=<PDISKID>, where id is the controller ID. The
<PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller
IDs and then type omreport storage pdisk
controller=ID to display the IDs for the physical disks
attached to the controller.
NOTE: To convert multiple RAID to non-RAID
on a given controller, use omconfig storage
controller action=convertraidtononraid command. For
more information, see omconfig Convert Multiple RAID To
Non-RAID.
Example to Convert RAID to non-RAID on physical disk 3 on connector 0
of controller 1. On a SAS controller, the physical disk resides in
enclosure 2.
Example for SAS controllers
omconfig storage pdisk action=raidtononraid
controller=1 pdisk=0:2:3
Omconfig Convert Non-RAID To RAID
Table 129. omconfig Convert Non-RAID To RAID
Description
Converts non-RAID to RAID on a physical disk.
Omconfig storage commands 149