Users Guide

Table Of Contents
information does not cause any functional limitation. If you are creating partial virtual disks, it is recommended that you
provide Storage Management adequate time between each partial virtual disk creation process.
NOTE: RAID 1 VD on SWRAID controller will enumerate for the attribute Stripe Element Size as NA.
RAID Levels Supported By The PERC Software RAID Controllers
Table 60. RAID Levels Supported by PERC S150 Controllers
RAID Level PERC S150
RAID 0 Yes
RAID 1 Yes
RAID 5 Yes
RAID 10 Yes
RAID 50 No
RAID 6 No
RAID 60 No
Read Write Cache And Disk Cache Policy Supported By The PERC
Software RAID Controllers
Table 61. Read, Write, and Cache Policy Supported by the PERC S150 Controllers
Read, Write, and Cache Policy PERC S150
Cache settings Yes
Read Policy Yes
Read Ahead (Enabled) Yes
No Read Ahead (Disabled) Yes
Write Policy Yes
Write Back (Enabled) Yes
Write Through (Disabled) Yes
Force Write Back (Enabled Always) No
Write Cache Enabled Protected No
Cache Policy No
Disk Cache Policy No
Cache I/O No
Direct I/O No
Enclosure Support On The PERC Software RAID Controllers
Supported Features
175