Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.0.1
- Contents
- Introduction
- What’s New in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 725. Cache Device Table Entry (continued)
Index
cacheDevicechassisIndex
,
cacheDeviceIndex
Table 726. Cache Device Chassis Index
Name
cacheDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 727. Cache Device Index
Name
cacheDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2
Description Defines the index of the cache device in this chassis.
Syntax DellObjectRange
Access Read-only
Table 728. Cache Device State Capabilities
Name
cacheDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3
Description Description Defines the capabilities of the cache device.
Syntax DellStateCapabilities
Access Read-only
Table 729. Cache Device State Settings
Name
cacheDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.4
Description Description Defines the state of the cache device.
Syntax DellStateSettings
Access Read-only
Table 730. Cache Device Status
Name
cacheDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5
Description Defines the status of the cache device.
Syntax DellStatus
Access Read-only