Release Notes

Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
113370 Intelligent mirror
VDs
RAID 10 virtual disk creation using intelligent mirroring
fails, as the support is not available from OM 9.4.
Not available
Not available Polling interval To determine the changes made on an enclosure
connected to HBA 11 controller and later versions, the
polling interval is set to five minutes. Therefore, it takes
approximately six minutes to generate an enclosure
event report and update its properties. However, if a
change it made to the enclosure environment status but
reverted to the previous status within this predefined
five minutes, then an event is not recorded. For
example, if a fan is removed but installed back within
five minutes, then an event is not recorded for this
purpose.
Not available
94402 Mapping alerts are
not displayed on
MX5016s
The alerts are not displayed when a physical disk is
inserted or removed on enclosure MX5016s mapping or
unmapping.
Not available
186184,
187434
Enclosure alerts If an enclosure is connected to HBA 355e controller,
then some of the enclosure-related alerts such as EMM
events, FAN events, PSU events Redundancy lost,
Redundancy restored events are not generated.
Restart Data Manager Service
to update a component status.
188961 Core dump
generated while
stopping the dcim
service
If HBA 10 or HBA 11 controller is present in the
server, then OpenManage generates a core dump while
stopping the dcim service.The dcim service stops at
several other instances such as upgrading OpenManage
and so on.
Not available
178110 Non-RAID drives If non-RAID predictive failure drives are connected to
enclosures, then the enclosure status may not always
be indicated as READY.
Not available
175332 Storage
Management
operations are
delayed
On Storage Management operations may get delayed or
may not come up for some time, whenever the physical
disks or enclosures are inserted or mapped or even
removed or unmapped from MX5016s.
Not available
179687 Initialization error If NVMe drive with initialization error is connected, then
that slot will not enumerate in slot occupancy report
and total slot count will be less.
Not available
Not available Reading BOSS-
related alerts from
sequence number 0
When OpenManage Server Administrator (OMSA) is
installed on a newly installed operating system, it starts
reading BOSS-related alerts from sequence number
0. Hence, if there are any earlier events present in
memory, then the OMSA will generate those events
again.
Performing LC wipe cannot
clear the earlier events
completely.
194278 Server with
multipath
configuration
generates a core
dump
If a server connected to Array584MM enclosures is
multipath configured with HBA355e controller, then the
OpenManage generates a core dump while hot-plugging
an enclosure on VMware ESXi.
Not available
193760 Server with
multipath
configuration with
daisy chain
generates a core
dump
If a server connected to MD14XX enclosures is
multipath with daisy chain configuration and HBA355e
controller, then the OpenManage generates a core
dump while hot-plugging an enclosure.
Not available
23