Release Notes
Table Of Contents
- Dell EMC OpenManage Release Notes Version 10.0.1
- Product description
- OMSA Customer Survey
- Platforms Affected
- Requirements
- What’s new in this release
- Installation Procedure
- Known issues and workarounds for Server Administrator
- User notes
- Storage Management Service
Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
Not available The Submit button On UI if the submit button is clicked more than once an
internal error may occur, but the task will be performed
successfully.
Not available
132214 Managed preserved
task
Few minutes delay occurs to disable the Managed
preserved cache task from the task list, after clicking
on Discard preserved cache.
Not available
125130 Encrypted VDs Physical disks, that were part of an encrypted virtual
disk that has been deleted, still show ‘Encrypted’
property as ‘Yes.
Not available
136314 NVMe device
protocol
The NVMe device protocol for Intel NVMe P4800x
devices is displayed as NVMe 1.1 instead of NVMe 1.0
on supported Linux distros .
Not available
Not available Physical device part
number
On BOSS controller the failed alert for the physical disk
part number will be displayed as NULL.
Not available
125128 Import EKM
encrypted VD
Importing an EKM Encrypted virtual disk on a normal
or non-EKM setup, displays a blank page on Foreign
Configuration Wizard.
Not available
Not available PDR events On PERC and HBA controllers PDR16, PDR51, PDR7
and PDR22 events are generated once in 24 hours.
Not available
Not available PDR events On PERC and HBA Controller use a single event PDR16
for the events PDR16 and PDR19.
Not available
151771 Multiple partial
spanned RAID-10
On Software RAID controllers, while creation of multiple
partial spanned RAID-10 virtual disks, the physical disks
SATA or NVMe belonging to a span in one virtual disk.
This might be distributed across the spans for another
virtual disk formed on the same disk group.
Not available
151463 Slot occupancy
report
On RHEL 7.7 and SLES 15 SP1 the slots occupancy
report does not display the empty slot available for
HBA330 controller.
Not available
153490 Slot occupancy
report
On PowerEdge R7515 system with 8 SAS or SATA and
16 NVMe backplane configuration, the slot occupancy
report for hardware PERC controller displays as 12 slots
instead of 8 slots that are connected to hardware PERC
controller.
Not available
143512 EMM alert
generation
The EMM alert generation is delayed if there are failed
drives present in the enclosure.
Not available
Not available Export log Export log operation may fail for failed state drive. Not available
Not available Failed drive
enumeration
Part Number, Serial No, Product ID, Vendor ID,
Firmware Revision, Sub-vendor ID, Model Number
values may not enumerate for failed state drive.
Not available
162168 (CR) Toshiba NVMe
drive
Sometimes when the Toshiba NVMe drive on the
SWRAID controller is connected (and is part of a Virtual
Disk), or a failed NVMe drive is present in the system.
There can be multiple PDR211 alerts that are logged
in the alert log page. The logs can lead to delayed of
response on the GUI.
Not available
161708 Data transfer on
M.2 drives
If the data transfer is not performing on M.2 drives
while performing hot-plug out operation, then after hot
plug-in back the same, the virtual disk rebuild alert will
not be generated. The virtual disk status will change
from degraded to online.
Not available
21