Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
95176 Intelligent mirror
VDs
The Physical disks available in MX5016s connected to
chassis slot 8 does not support RAID-10 intelligent
mirror virtual disk creation.
Not available
101739 EMM failure alerts If an EMM is removed from MX5016s sled, EMM failure
or removal alert is not observed on Server Administrator
alerts.
Not available
109008 Backplane
enumeration
Storage Management is enumerating more than one
backplane that is not connected to SWRAID controller
under SWRAID controller (S140) on PowerEdge
R740xd2 system.
Not available
98675 Hot-plugged
devices
On Server Administrator page, a delay is observed on
hot-pluggable devices when hot-plugged in or out on
HBA 330 MMZ.
Not available
110132 Enclosure hot-plug When the enclosure is hot plug-in to the 12GBPS HBA
controller observes an additional physical disk id in alert
log page.
Not available
112768 Intel NVMe P4800x
devices
On systems running SUSE Linux Enterprise 15.0
operating system the device protocol of Intel NVMe
P4800x devices display NVMe 0.0 instead of NVMe 1.0.
Not available
111625, 112746 Create or delete
VDs
In a maximum configuration setup i.e. eight enclosures
connected to PERC H840 controller, performing
creating or deleting virtual disk operation multiple times
with more than 160 plus physical drives on systems
running ESXi operating system.We observe core or
virtual disk creation failure.
Restart sfcbd service.
108887 XML data
generated
On Storage Management, observes intermittently
malformed alert log showing XML Data generated for
the selection made is not well formed on systems
running ESXi operating system.
Clear logs and restart the
service.
119082 Multipath mode On multipath mode, if clear redundant path option is
performed immediately after removing the enclosure
cable, few minutes of delay is observed on Server
Administrator UI to refresh.
Recommendation : It is recommended to wait for the
Redundant path broken alerts before performing the
clear redundant path. If in case Server Administrator
page delay is observed, wait for few minutes to return
to the normal state page or restart the service.
Not available
120251 Orphan drive The foreign physical disks connected to the system, on
reaching the maximum number of supported virtual disk
by the controller is displayed on the Import Preview
page as Orphan Drive.
Not available
117872 Unblink operation On performing the unblink operation on physical disk
connected to 12Gbps SAS HBA, observing both health
and activity LEDs light turn off.
Not available
128978 Import foreign
configuration task
is not successful
When there is failed virtual disk in the same controller
the Import foreign configuration on controllers task,
does not list the available degraded virtual disks to
import, recover or clear. The list can be observed after
failed virtual disk deletion.
Not available
20