Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
remove the physical disks
from the controller.
DF60696 Internet Explorer
9.x or 10.x
Storage Management responds slowly when using
Internet Explorer 9.x or 10.x on a system with
mixed SAS and SATA physical disks. When using
the "Create Virtual Disk" wizard from the Storage
Management graphical user interface (GUI), you may
notice decreased performance when using Internet
Explorer 9.x or 10.x on a system with multiple physical
disks. The MD1400/MD1420/Array584EMM storage
enclosures that are heavily populated with mixed SAS
and SATA physical disks.
Use a supported web
browser other than Internet
Explorer 9.x or 10.x or
use the Storage Management
command line interface (CLI)
to create the virtual disk. See
the Dell EMC OpenManage
Server Administrator Release
Notes for information on
supported browsers. See
the Storage Management
online Help or the "Server
Administrator Command Line
Interface User's Guide" for
information on using the
Storage Management CLI.
DF152362 Storage
Management may
not display
controllers
Storage Management may not recognize the controller
devices that are installed after Storage Management is
already running.
If Storage Management does
not recognize a newly-added
device and this problem has
not been corrected with a
Global Rescan, then reboot the
system.
DF120475 Storage
Management
SNMP traps
Server Administrator allows you to filter SNMP traps
that you do not want to receive. To implement
SNMP trap filtering, select the System tree > Alert
Management tab > SNMP Traps subtab. The SNMP
Traps subtab has options for enabling and disabling
SNMP traps based on severity or the component that
generates the trap. Even when the SNMP traps are
disabled, Storage Management generates SNMP traps.
SNMP trap filtering will be
provided in a future release of
Storage Management.
Not available omconfig storage When issuing certain omconfig storage CLI commands
with Power User privileges, the Error! User has
insufficient privileges to run command: omconfig
message may be displayed.
You must be logged in as an
Administrator to perform these
actions.
Not available Advanced Create
Virtual Disk
Using the Storage Management Service Advanced
Create Virtual Disk Wizard may occasionally result
in a vertical scrollbar of less than normal width. If
this occurs, resizing the Server Administrator window
causes the vertical scrollbar to be redrawn correctly.
Not available
Not available Rename virtual disk Using the GUI, if a virtual disk is renamed to a name
containing multiple blank and consecutive spaces, the
name is truncated to a single space after Apply is
clicked.
Not available
BITS118226 NVMe devices The representation of NVMe devices residing on
backplanes that attach to PCIe Extender cards is
inaccurate on Storage Management. This is because
Storage Management does not have a process
to understand the mapping of the NVMe device,
backplane, and the PCIe Extender card. This issue
exists only on PowerEdge R920 servers and does
not impact the operations on the NVMe device.
Multiple backplanes on Server Administrator indicate
the presence of multiple PCIe Extender cards on the
system.
Not available