User's Manual

Fluid Cache for DAS 79
Failure Predicted Displays whether the physical disk has received a Self-
Monitoring Analysis and Reporting Technology
(SMART) alert and is therefore predicted to fail. For
more information on SMART predictive failure analysis,
see
Monitoring Disk Reliability on RAID Controllers
. For
information on replacing the physical disk, see
Replacing
a Physical Disk Receiving SMART Alerts
.
You may also want to review the Alert Log to see if the
physical disk has generated alerts pertaining to a
SMART predictive failure. These alerts can assist you in
identifying the cause of the SMART alert. The following
alerts may be generated in response to a SMART alert:
2094
2106
2107
2108
2109
2110
2111
For information on Alert Messages, see the Dell
OpenManage Server Administrator Messages Reference
Guide at support.dell.com/manuals.
On a PERC4/IM controller, when replacing a drive that
displays a SMART error with another drive, it is
necessary to perform a rescan operation on the
controller, for Storage Management to display the
correct status of the newly inserted drive.
Revision Displays the firmware version of the drive.
Driver Version Displays the version number of the driver.
Device Life Status Displays the health status of the physical device.
Model Number Displays the model number of the physical device.
Capacity Displays the capacity of the physical device.
Table 6-4. Physical Device Properties
(continued)
Properties Description