User's Manual
192 RAID Controller Batteries
Table 11-1. Battery Properties
Property Definition
Status These icons represent the severity or health of the storage
component.
Normal/OK
Warning/Non-critical
Critical/Fatal
For more information, see
Storage Component Severity
.
Name This property displays the name of the battery.
State This property displays the current status of the battery.
Possible values are:
Charging—The battery is undergoing the recharge phase of
the battery learn cycle. For more information, see
Start
Learn Cycle
.
Missing—The controller is missing a battery.
Failed—The battery has failed and needs to be replaced.
Learn Mode Auto—Storage Management performs an automatic learn
cycle based on the time you set.
Warn—The Learn cycle is past the default 90 days.
NOTE: Warn is available only on SAS controllers with
firmware version 6.1 and later.
Next Learn Time This property displays the number of days and hours left
before the controller firmware initiates the next Learn
cycle.
Maximum Learn
Delay
This property displays the maximum number of days and
hours that you can delay the battery learn cycle. The
controller firmware automatically initiates the battery learn
cycle. You cannot stop or pause the Learn cycle, but you
can delay it. For more information, see
Battery Delay Learn
Cycle
and
Start Learn Cycle
.