User's Manual

Enclosures and Backplanes 165
Drop-down Menu Enclosure Tasks:
Enable Alarm (Enclosure)
Disable Alarm (Enclosure)
Set Asset Data
•Blink
Set Temperature Probe Values
Available Reports
To view a report:
1
Expand the
Storage
tree object to display the controller objects.
2
Expand a controller object.
3
Expand a
Connector
object.
4
Select the enclosure object.
5
Select the
Information/Configuration
subtab.
6
Select a report from the
Select Report
drop-down menu.
7
Click
Execute
.
Available Reports
View Slot Occupancy Report
Enable Alarm (Enclosure)
Does my enclosure support this feature? See
Supported Features
.
Use the Enable Alarm task to enable the enclosure alarm. When enabled, the
audible alarm sounds whenever the fault LED lights. This may occur to signal
events such as:
The enclosure temperature has exceeded the warning threshold.
A power supply, fan, or enclosure management module (EMM) has failed.
The split bus is not installed. (A split bus is indicated by a single triangle
symbol on the back of the enclosure.)