SNMP Reference Guide

756 Traps
Amperage Probe Failure
1204 Current sensor detected a failure value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete: Current
sensor value (in Amps): <Reading>
If sensor type is discrete: Discrete
current state: <State>
Error A current sensor on the
power supply for the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous state,
and current sensor
value are provided.
Amperage Probe Non-recoverable
1205 Current sensor detected a
non-recoverable value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete: Current
sensor value (in Amps): <Reading>
If sensor type is discrete: Discrete
current state: <State>
Error A current sensor in the
specified system
detected an error from
which it cannot recover.
The sensor location,
chassis location,
previous state, and
current sensor value are
provided.
TrapID Description Severity Cause
book.book Page 756 Wednesday, March 6, 2013 12:37 AM