SNMP Reference Guide

670 Storage Management Group
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
DELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLY
Battery Connection Table
This section describes the connection between each controller battery on the
managed system and its controller. Each controller number in the table
corresponds to that controller instance in the controller Table.
The following object sets up the Battery Connection Table.
Battery Connection Entry
Battery Connection Number
Access Read-only
Name batteryConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16
Description Defines the battery connection table.
Syntax SEQUENCE OF BatteryConnectionEntry
Access Not accessible
Name batteryConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1
Description Defines the battery connection table entry.
Syntax BatteryConnectionEntry
Access BatteryConnectionEntry
Index BatteryConnectionNumber
Name batteryConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.1
Description Identifies the instance number of the battery connection entry.
Syntax Integer
Access Read-only
Name batteryLearnMode
book.book Page 670 Wednesday, March 6, 2013 12:37 AM