SNMP Reference Guide

196 Power Group
Table 8-12. AC Power Switch Redundancy Mode
Variable Name:
DellACPowerSwitchRedundancyMode
Data Type: Integer
Possible Data Values Meaning of Data Value
nonRedundant(1) The AC power switch is not expecting redundancy.
redundant(2) The AC power switch is expecting redundancy.
Table 8-13. AC Power Cord State Capabilities
Variable Name:
DellACPowerCordStateCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power cord’s capabilities are unknown.
onlineCapable(2) The AC power cord can be disabled (offline) or
enabled (online).
notReadyCapable(4) The AC power cord’s capabilities are not ready.
Table 8-14. AC Power Cord State Settings
Variable Name:
DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power cord’s state is unknown.
online(2) The AC power cord’s state is disabled (offline) 0 or
enabled (online) 1.
notReady(4) The AC power cord’s state is not ready.
acPowerCordHasPower
(8)
The AC power cord has power.
acPowerCordIsActive
Source(16)
The AC power cord is the active source of
AC power.
book.book Page 196 Wednesday, March 6, 2013 12:37 AM