book.book Page 1 Wednesday, March 6, 2013 12:37 AM Dell OpenManage Server Administrator SNMP Reference Guide Version 7.1.
book.book Page 2 Wednesday, March 6, 2013 12:37 AM Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. __________________ Information in this publication is subject to change without notice. © 2013 Dell Inc. All rights reserved. Reproduction of these materials whatsoever without the written permission of Dell Inc. is strictly forbidden.
book.book Page 3 Wednesday, March 6, 2013 12:37 AM Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . What’s New in This Release . . . . . . . . . . . . . . 17 . . . . . . . . . 17 . . . . . . . . . . . . . . . . . . . . 17 Storage Management Group MIB iDRAC7 MIB 17 Supported SNMP Versions . . . . . . . . . . . . . . . Introduction to the SNMP Reference Guide . . . . . . 18 18 Server Administrator Instrumentation MIB . . . .
book.book Page 4 Wednesday, March 6, 2013 12:37 AM SNMP Traps 2 3 . . . . . . . . . . . . . . . . . . . . Instrumentation MIB Version Group . . . . 41 Management Information Base Major Version Number 41 Management Information Base Minor Version Number 42 Management Information Base Maintenance Version Number . . . . . . . . . . . . . . . . 42 . . . . . Systems Management Software Group . Systems Management Software . 43 . . . . . . . . . . . . 43 . . . 47 System State Group . . . . .
book.book Page 5 Wednesday, March 6, 2013 12:37 AM 6 Operating System Group . . . . . . . . . . . . Operating System Memory Table 7 System Resource Group 131 . . . . . . . . . . . 131 . . . . . . . . . . 133 System Resource Owner Table . . 136 System Resource Memory Table . . . . . . . . . . 139 System Resource Interrupt Table . . . . . . . . . 142 System Resource Input/Output (I/O) Port Table System Resource Direct Memory Access (DMA) Table . . . . . . . . . . . . . . .
book.book Page 6 Wednesday, March 6, 2013 12:37 AM Cooling Device Table . . . . . . . . . . . . . . . . Temperature Probe Table Thermal Group Variable Values 10 User Security Group . . . . . . . . . . . . . 209 . . . . . . . . . . . . . 215 . . . . . . . . . . . . . . . User Security Group Table User Security Table . 219 . . . . . . . . . . . . . . . . 219 Remote Flash BIOS Group Table Remote Flash BIOS Table . . . . . . . . . . . . 223 . . . . . . . . . . . . . 223 . . . . . . . . . . .
book.book Page 7 Wednesday, March 6, 2013 12:37 AM Pointing Device Table 264 . . . . . . . . . . . . . . . Keyboard Device Table . . . . . . . . . . . . . . . 266 Processor Device Table . . . . . . . . . . . . . . 269 Processor Device Status Table Cache Device Table . . . . . . . . . . 277 . . . . . . . . . . . . . . . . 279 Memory Device Table . . . . . 293 . . . . . . . . . . . . . . . 296 . . . . . . . . . . . . . . . . . .
book.book Page 8 Wednesday, March 6, 2013 12:37 AM 16 BIOS Setup Control Group . BIOS Setup Control Group Tables 391 . . . . . . . . . . . . . 391 . . . . . . . . . . . . . . . . . 402 Parallel Port Control Table . . . . . . . . . . . . . 404 . . . . . . . . . . . . . . 406 . . . . . . . . . . . . . . . . . 408 . . . . . . . . . . . . . . . . . . 410 Serial Port Control Table USB Control Table IDE Control Table Diskette Control Table . . . . . . . . . . . . . . .
book.book Page 9 Wednesday, March 6, 2013 12:37 AM COO Repair Table . COO Support Information Table COO Trouble Ticket Table . . . . . . . . . . 466 . . . . . . . . . . . . . 468 Cost of Ownership Variable Values 19 Remote Access Group . DRAC 4 and DRAC 5 470 . . . . . . . . . . . . . . . . . . . . . . . . 473 473 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473 . . . . . . . . . . . . . . . . . . . . . . . . . 479 Remote Access Table DRAC III 464 . . . . . . . . .
book.book Page 10 Wednesday, March 6, 2013 12:37 AM Baseboard Management Controller Group Variable Values . . . . . . . . . . . . . . 22 Field Replaceable Unit Group Field Replaceable Unit Group Tables Field Replaceable Unit Table . . . . . . . . . . . . . . . 549 . . . . . . . . . . . . 549 23 Storage Management Group . . . . . . . . . . . . . . 555 555 557 . . . . . . . . . . . . . . . . . . . . 558 . . . . . . . . . . . . . . . . . 564 . . . . . . . . . . . . . . . . . . 565 . . . . . .
book.book Page 11 Wednesday, March 6, 2013 12:37 AM Logical Devices Group . . . . . . . . . . . . . . . . . 672 Virtual Disk Table . . . . . . . . . . . . . . . . . . 672 Virtual Disk Partition . . . . . . . . . . . . . . . . 684 . . . . . . . . . . . . . . . . . 687 . . . . . . . . . . . . . . . . . . 691 Fluid Cache Table Fluid Cache Disk Fluid Cache Pool Table Array Disk Logical Connection Table Storage Management Event Group . . . . . . . 698 . . . . . . . . . . .
book.book Page 12 Wednesday, March 6, 2013 12:37 AM Legacy Alerting 26 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Understanding the Trap Description 741 . . . . . . . . . . . . . . 745 . . . . . . . . . . . . . . . . . . 746 Miscellaneous Traps . . . . . . . . . . . . . . . . Temperature Probe Traps 749 Cooling Device Traps . . . . . . . . . . . . . . . . 751 Voltage Probe Traps . . . . . . . . . . . . . . . .
book.book Page 13 Wednesday, March 6, 2013 12:37 AM Alert Severity Levels 782 . . . . . . . . . . . . . . . . . . SNMP Support for Storage Management Alerts . . . . 783 . . . . . . . . . . . . . . 783 SNMP Trap Definitions . . . . . . . . . . . . . . . 784 SNMP Trap Variables . . . . . . . . . . . . . . . 784 . . . . . . . . . . . . . . . . . . 785 SNMP Trap Forwarding Viewing SNMP Traps Alert Descriptions and Corrective Actions 28 iDRAC7 MIB . 785 . . . . . . . . . . . . . . . . . .
book.book Page 14 Wednesday, March 6, 2013 12:37 AM Variables with Data Types of State Capabilities and State Capabilities Unique . . . . . . . . . . . . . . . . 820 . . . . . . . . . . . . . . . . . 822 . . . . . . . . . . . . . . . . . . . . . . . . . 823 Dell Status Data Types . Dell Date Full Dates . . . . . . . . . . . . . . . . . . . . . . B SNMP Sample Output Index 14 824 . . . . . . . . . . . . . . 825 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
book.book Page 17 Wednesday, March 6, 2013 12:37 AM 1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7.1. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections.
book.book Page 18 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm deprecated, refer to the Dell OpenManage Server Administrator Version 7.1 User's Guide and Dell Systems Software Support Matrix Version 7.1 at www.dell.com/support/manuals.
book.book Page 19 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Server Administrator Instrumentation MIB The Server Administrator Instrumentation MIB (filename 10892.mib) provides instrumentation data that allows you to monitor the health of a system with SNMP management applications.
book.book Page 20 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Table 1-2.
book.book Page 21 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Table 1-2.
book.book Page 22 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Table 1-3.
book.book Page 23 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Table 1-4. Server Administrator Field Replaceable Unit MIB Sections in This Guide Section Topic MIB Group Numbers 22 Field Replaceable Unit Group — provides information about 2000 field replaceable units that may be present in your system Server Administrator Storage Management MIB The Server Administrator Storage Management MIB (filename dcstorag.
book.book Page 24 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Server Administrator Change Management MIB The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications. Table 1-6 describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group.
book.book Page 25 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Table 1-7.
book.book Page 26 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm SNMP Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at support.dell.com/manuals.
book.book Page 27 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm The SNMP extension agent communicates with the SNMP master agent using an extension protocol defined by the SNMP master agent. The Server Administrator SNMP subagent is an SNMP extension agent. Managed Object A managed object is any item in a computer system that can be singled out for discovery, monitoring, or user intervention and correction.
book.book Page 28 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Name is the exact string by which the variable is known in the MIB. MIB variables are named according to the following conventions: • Variable names start with a lowercase letter. • Spaces are not allowed between words in the variable name. • Acronyms are in uppercase letters, except when an acronym is the first word in the variable name.
book.book Page 29 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Description is a brief explanation of what a particular managed object does. Syntax defines the data type in which the values of the variable must be expressed. Most variables in this reference guide use standard data types such as string or boolean. All data types that are unique to server administrator variables are defined at the end of the section in which they occur.
book.book Page 30 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays.
book.book Page 31 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 32 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE[16]) Access Read-only Reference Guide Content Tables NOTE: Variable values are defined for any variable that is Server Administrator-specific.
book.book Page 33 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables.
book.book Page 34 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm 4 BIOS Variable Values This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings. Information on each Server Administrator-specific variable is presented in a formatted table.
book.book Page 35 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms. Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB.
book.book Page 36 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm SNMP Management Information Base Object Identifiers Each data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number. The phone number 011-512-471-0000 uniquely identifies a single phone.
book.book Page 37 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism.
book.book Page 38 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm Management Actions Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, "SNMP Security" on page 37, for limitations on Set operations.
book.book Page 39 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm For a list of traps supported by the Server Administrator Instrumentation Service, see "Instrumentation Traps" on page 696. For information on Server Administrator Storage Management traps, see "Storage Management Alert Reference" on page 753. For a list of traps supported by the Remote Access Controller, see "RAC Traps" on page 742, "BMC Traps" on page 747 and "iDRAC7 Traps" on page 767.
book.book Page 40 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.
book.book Page 41 Wednesday, March 6, 2013 12:37 AM 2 Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.
book.book Page 42 Wednesday, March 6, 2013 12:37 AM Management Information Base Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.0 Description Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2. A minor revision provides additional support for new objects as well as problem fixes.
book.book Page 43 Wednesday, March 6, 2013 12:37 AM Systems Management Software Group 3 The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
book.book Page 44 Wednesday, March 6, 2013 12:37 AM Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.1 Description Defines the systems management software product name. Syntax DellString Access Read-only Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1.3.6.1.4.1.674.10892.1.100.2 Description Defines the version number of the systems management software.
book.book Page 45 Wednesday, March 6, 2013 12:37 AM Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.5 Description Defines the systems management standards (SNMP or CIM) supported by the systems management software. Syntax SMSSupportedTypes (See Table 3-1) Access Read-only Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 46 Wednesday, March 6, 2013 12:37 AM Name systemManagementSoftwareURLName Access Read-only Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software. Syntax DisplayString (SIZE (0..255)) Access Read-only Systems Management Software Global Version Name Name systemManagementSoftwareGlobalVersionName Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 47 Wednesday, March 6, 2013 12:37 AM Name systemManagementSoftwareSNMPAgentFeatureFlags Syntax SMSSNMPAgentFeatureFlags (See Table 3-3) Access Read-only Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software.
book.book Page 48 Wednesday, March 6, 2013 12:37 AM Table 3-2. Systems Management Software Feature Flags Variable Name: SMSFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value none(0) The Systems Management Software features are not enabled. webOneToOneManagementPreferred(1) The web 1:1 management preferred feature is enabled. Table 3-3.
book.book Page 49 Wednesday, March 6, 2013 12:37 AM 4 System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes.
book.
book.
book.book Page 52 Wednesday, March 6, 2013 12:37 AM System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance.
book.book Page 53 Wednesday, March 6, 2013 12:37 AM System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit.
book.book Page 54 Wednesday, March 6, 2013 12:37 AM System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8 Description Defines the state of all power supplies in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power supply.
book.book Page 55 Wednesday, March 6, 2013 12:37 AM System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe.
book.book Page 56 Wednesday, March 6, 2013 12:37 AM System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe.
book.book Page 57 Wednesday, March 6, 2013 12:37 AM System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit.
book.book Page 58 Wednesday, March 6, 2013 12:37 AM System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device.
book.book Page 59 Wednesday, March 6, 2013 12:37 AM System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23 Description Defines the state of all temperature probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe.
book.book Page 60 Wednesday, March 6, 2013 12:37 AM System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device.
book.book Page 61 Wednesday, March 6, 2013 12:37 AM System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
book.book Page 62 Wednesday, March 6, 2013 12:37 AM System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32 Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax Octet String (Size(1..
book.book Page 63 Wednesday, March 6, 2013 12:37 AM System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35 Description Defines the individual state of all AC power cords for any AC power switches in this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on. Syntax Octet String (Size(1..
book.book Page 64 Wednesday, March 6, 2013 12:37 AM System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38 Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on.
book.book Page 65 Wednesday, March 6, 2013 12:37 AM System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis.
book.book Page 66 Wednesday, March 6, 2013 12:37 AM System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44 Description Defines the combined status of all cooling units of this chassis. Syntax DellStatus Access Read-only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45 Description Lists the status of each cooling unit of this chassis.
book.book Page 67 Wednesday, March 6, 2013 12:37 AM System State AC Power Switch Status List Name systemStateACPowerSwitchStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47 Description Lists the status of each AC power switch of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch. The first byte returned represents the status of the first AC power switch, and so on.
book.book Page 68 Wednesday, March 6, 2013 12:37 AM System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
book.book Page 69 Wednesday, March 6, 2013 12:37 AM Name systemStateBatteryStatusList Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..
book.book Page 70 Wednesday, March 6, 2013 12:37 AM Name systemStateSDCardDeviceStatusCombined Syntax DellStatus Access Read-only System State SD Card Device Status List Name systemStateSDCardDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.57 Description Lists the status of each SD Card device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device.
book.book Page 71 Wednesday, March 6, 2013 12:37 AM Chassis Information Group 5 The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
book.book Page 72 Wednesday, March 6, 2013 12:37 AM Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 73 Wednesday, March 6, 2013 12:37 AM Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the status of the chassis. Syntax DellStatus Access Read-only Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any.
book.book Page 74 Wednesday, March 6, 2013 12:37 AM Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis.
book.book Page 75 Wednesday, March 6, 2013 12:37 AM Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12 Description Defines the asset tag name for this chassis. Syntax DellUnsigned8BitRange Access Read-only Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.
book.book Page 76 Wednesday, March 6, 2013 12:37 AM Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17 Description Defines the current time on this system.
book.book Page 77 Wednesday, March 6, 2013 12:37 AM Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 78 Wednesday, March 6, 2013 12:37 AM Chassis LED Control Capabilities Unique Name chassisLEDControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24 Description Defines the capabilities of the LED control function in the chassis. Syntax DellLEDControlCapabilities (See Table 6-5) Access Read-only Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 79 Wednesday, March 6, 2013 12:37 AM Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Table 6-9) Access Read-only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 80 Wednesday, March 6, 2013 12:37 AM Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32 Description Defines the current settings of the host control object. Syntax DellHostControlSettings (See Table 6-12) Access Read-write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 81 Wednesday, March 6, 2013 12:37 AM Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36 Description Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object. Syntax DellUnsigned16BitRange Access Read-write Chassis Allow Set Commands From SNMP Name chassisallowSETCommandsfromSNMP Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 82 Wednesday, March 6, 2013 12:37 AM Name chassisPowerButtonControlSettingsUnique Syntax DellPowerButtonControlSettings (See Table 6-17) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 83 Wednesday, March 6, 2013 12:37 AM Name chassisResellerSystemID Syntax DellUnsigned16BitRange Access Read-only Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function.
book.book Page 84 Wednesday, March 6, 2013 12:37 AM Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47 Description Defines the revision number of the system where zero indicates the original version of the system. The revision number is not available on all systems. Syntax DellUnsigned8BitRange Access Read-only Chassis System Revision Name Name chassisSystemRevisionName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 85 Wednesday, March 6, 2013 12:37 AM Name uUIDTable Access Not accessible UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 86 Wednesday, March 6, 2013 12:37 AM Name uUIDType Syntax DellUUIDType Access Read-only UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE(16)) Access Read-only POST Log Table This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads.
book.book Page 87 Wednesday, March 6, 2013 12:37 AM Name postLogTableEntry Access Not accessible Index postLogchassisIndex, postLogRecordIndex POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.
book.book Page 88 Wednesday, March 6, 2013 12:37 AM Name postLogStateSettingsUnique Syntax DellStateSettingsLogUnique Access Read-write POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.
book.book Page 89 Wednesday, March 6, 2013 12:37 AM Name eventLogTableEntry Description Defines the event Log Table Entry. Syntax EventLogTableEntry Access Not accessible Index eventLogchassisIndex,eventLogRecordIndex Event Log Chassis Index Name eventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.
book.book Page 90 Wednesday, March 6, 2013 12:37 AM Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.4 Description Defines the state settings for the object that is writing the event log. Syntax DellStateSettingsLogUnique Access Read-write Event Log Record Name eventLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5 Description Defines the data for the specified chassis and log record index in the event log being returned.
book.book Page 91 Wednesday, March 6, 2013 12:37 AM Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Name systemBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.300.50 Description Defines the System BIOS Table.
book.book Page 92 Wednesday, March 6, 2013 12:37 AM Name systemBIOSchassisIndex Access Read-only System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3 Description Defines the capabilities of the system BIOS of this object.
book.book Page 93 Wednesday, March 6, 2013 12:37 AM Name systemBIOSStatus Access Read-only System BIOS Size Name systemBIOSSize Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.6 Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown. Syntax DellUnsigned32BitRange Access Read-only System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.
book.book Page 94 Wednesday, March 6, 2013 12:37 AM Name systemBIOSStartingAddress Description Defines the starting address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10 Description Defines the ending address of the system BIOS. A zero (0) indicates that the address is unknown.
book.book Page 95 Wednesday, March 6, 2013 12:37 AM Name systemBIOSCharacteristics Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit 63 is the first bit in the value, and bit 0 is the last bit in the value. See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value. Bits 48-63 need to be examined in the context of the system ID.
book.book Page 96 Wednesday, March 6, 2013 12:37 AM Name systemBIOSCharacteristics Description Bit Position Meaning if Set -------------- -----------------Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card (PCMCIA) is supported Bit 19EDD (Enhanced Disk Drive) Specification is supported Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.
book.book Page 97 Wednesday, March 6, 2013 12:37 AM Name systemBIOSCharacteristicsExt1 Description Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
book.book Page 98 Wednesday, March 6, 2013 12:37 AM Firmware Table Name firmwareTable Object ID 1.3.6.1.4.1.674.10892.1.300.60 Description Defines the Firmware Table. Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Firmware Table Entry Name firmwareTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.60.1 Description Defines the Firmware Table entry.
book.book Page 99 Wednesday, March 6, 2013 12:37 AM Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3 Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4 Description Defines the state of the firmware and allows for the setting of the firmware.
book.book Page 100 Wednesday, March 6, 2013 12:37 AM Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware. Syntax DellFirmwareType Access Read-only Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.
book.book Page 101 Wednesday, March 6, 2013 12:37 AM Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed. Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.
book.book Page 102 Wednesday, March 6, 2013 12:37 AM Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup. Syntax DellObjectRange Access Read-only Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3 Description Defines the capabilities of the intrusion object.
book.book Page 103 Wednesday, March 6, 2013 12:37 AM Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.
book.book Page 104 Wednesday, March 6, 2013 12:37 AM Baseboard Table Entry Name baseBoardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.80.1 Description Defines the Baseboard Table entry. Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex, baseBoardIndex Baseboard Chassis Index Name baseBoardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 105 Wednesday, March 6, 2013 12:37 AM Baseboard State Settings Name baseBoardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4 Description Defines the state settings of the baseboard. Syntax DellStateSettings Access Read-write Baseboard Status Name baseBoardStatus Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5 Description Defines the status of the baseboard. Syntax DellStatus Access Read-only Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.
book.book Page 106 Wednesday, March 6, 2013 12:37 AM Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard.
book.book Page 107 Wednesday, March 6, 2013 12:37 AM Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12 Description Defines the baseboard version name. Syntax DellString Access Read-only Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name.
book.book Page 108 Wednesday, March 6, 2013 12:37 AM Baseboard Express Service Code Name Name baseBoardExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.16 Description Defines the express service code of the baseboard. Syntax DellString Access Read-only Chassis Information Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 5-1.
book.book Page 109 Wednesday, March 6, 2013 12:37 AM Table 5-2. Chassis Type (continued) Variable Name: DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value tower(7) The chassis type is a tower. portable(8) The chassis type is a portable. lapTop(9) The chassis type is a laptop. noteBook(10) The chassis type is a notebook. handHeld(11) The chassis type is a handheld. dockingStation(12) The chassis type is a docking station.
book.book Page 110 Wednesday, March 6, 2013 12:37 AM Table 5-3. Connection Status Variable Name: DellConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value unknown(2) The status of the chassis connection is unknown. ok(3) The status of the chassis connection is OK. failure(4) The status of the chassis connection is failure. Table 5-4.
book.book Page 111 Wednesday, March 6, 2013 12:37 AM Table 5-6. Front-Panel LED Control Settings Variable Name: DellLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The LED control setting is unknown. alertOnError(2) The LED control is set to alert on an error condition. alertOnWarningAndError(4) The LED control is set to alert on an error or a warning condition. Table 5-7.
book.book Page 112 Wednesday, March 6, 2013 12:37 AM Table 5-8. Hard-Drive Fault LED Control Settings Variable Name: DellHDFaultLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any fault settings capabilities. unknown(1) The hard-drive fault LEDs’ state is unknown. enabled(2) The hard-drive fault LEDs’ state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
book.book Page 113 Wednesday, March 6, 2013 12:37 AM Table 5-9. Chassis Identification Control Capabilities (continued) Variable Name: DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis. Table 5-10.
book.book Page 114 Wednesday, March 6, 2013 12:37 AM Table 5-11. Host Control Capabilities Variable Name: DellHostControlCapabilities NOTE: An operator can manually enable these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualRebootCapable(1) The operator can reboot capable host. manualPowerOFFCapable(2) The operator can power off capable host. manualPowerCycleCapable(4) The operator can power-cycle capable host.
book.book Page 115 Wednesday, March 6, 2013 12:37 AM Table 5-12. Host Control Settings Variable Name: DellHostControlSettings NOTE: An operator can manually cause these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualReboot(1) The operator can reboot the host. manualPowerOFF(2) The operator can power off the host. manualPowerCycle(4) Power cycle the host. manualOperatingSystemShutdown(8) The operator can shut down the operating system on the host.
book.book Page 116 Wednesday, March 6, 2013 12:37 AM Table 5-13. Watchdog Control Capabilities (continued) Variable Name: DellWatchDogControlCapabilities NOTE: When the system determines that the operating system is not responding, it automatically performs the selected action without operator intervention.
book.book Page 117 Wednesday, March 6, 2013 12:37 AM Table 5-15. Watchdog Timer Capabilities Variable Name: DellWatchDogTimerCapabilities Data Type: Integer Possible Data Values Meaning of Data Value type1Capable(1) Watchdog timer can time in intervals from 20–480 seconds. type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and 480-second intervals. type3Capable(4) Watchdog timer can time in 60-second intervals. Table 5-16.
book.book Page 118 Wednesday, March 6, 2013 12:37 AM Table 5-18. NMI Button Control Capabilities Variable Name: DellNMIButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no capabilities. unknownCapabilities(1) The NMI button capabilities are unknown. The NMI button can be enabled (online) or disabled (offline). enableCapable(2) Table 5-19.
book.book Page 119 Wednesday, March 6, 2013 12:37 AM Table 5-21. Baseboard Type Variable Name: DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwitch(4) The baseboard type is a connectivity switch. systemManagementModule(5) The baseboard type is a system management module.
book.book Page 120 Wednesday, March 6, 2013 12:37 AM Table 5-22. Chassis System Class (continued) Variable Name: DellChassisSystemClass Data Type: Integer Possible Data Values Meaning of Data Value desktopClass(5) The chassis system class is a desktop. portableClass(6) The chassis system class is a portable. netPCClass(7) The chassis system class is a Net PC. storageClass(8) The chassis system class is storage. Table 5-23.
book.book Page 121 Wednesday, March 6, 2013 12:37 AM Table 5-23. Firmware Type (continued) Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value hotPlugPCI(11) The firmware type is Hot Plug Peripheral Component Interconnect (PCI) Controller. sensorData(12) The firmware type is Sensor Data Records. peripheralBay(13) The firmware type is Peripheral Bay Backplane. secondaryBackPlane(14) The firmware type is Secondary Backplane for ESM 2 systems.
book.book Page 122 Wednesday, March 6, 2013 12:37 AM Table 5-24. Baseboard Feature Flags Variable Name: DellBaseBoardFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value boardRequiresDaughterBoard This baseboard requires at least one (2) daughter board or auxiliary card. boardIsRemovable(4) This baseboard is removable. boardIsReplaceable(8) This baseboard is replaceable. boardIsHotSwappable(16) This baseboard is hot swappable.
book.book Page 123 Wednesday, March 6, 2013 12:37 AM Operating System Group 6 The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system.
book.book Page 124 Wednesday, March 6, 2013 12:37 AM Operating System Chassis Index Name operatingSystemchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.2 Description Defines the capabilities of the operating system.
book.book Page 125 Wednesday, March 6, 2013 12:37 AM Operating System Is Primary Name operatingSystemIsPrimary Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.5 Description Specifies whether this operating system is the primary operating system. Syntax DellBoolean Access Read-only Operating System Name Name operatingSystemOperatingSystemName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.6 Description Defines the name of the operating system running on the system. Syntax DisplayString (SIZE (0..
book.book Page 126 Wednesday, March 6, 2013 12:37 AM Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.20.1 Description Defines the Operating System Memory Table entry. Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
book.book Page 127 Wednesday, March 6, 2013 12:37 AM Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory. Syntax DellStatus Access Read-only Operating System Memory Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5 Description Defines the total physical memory size in kilobytes.
book.book Page 128 Wednesday, March 6, 2013 12:37 AM Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
book.
book.
book.book Page 131 Wednesday, March 6, 2013 12:37 AM System Resource Group 7 The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes "System Resource Group Tables" on page 131 that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
book.book Page 132 Wednesday, March 6, 2013 12:37 AM System Resource Map Table Entry Name systemResourceMapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.10.1 Description Defines the System Resource Map Table entry. Syntax SystemResourceMapTableEntry Access Not accessible Index systemResourceMapchassisIndex, systemResourceMapIndex System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.
book.book Page 133 Wednesday, March 6, 2013 12:37 AM System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4 Description Defines the state and allows the setting of this system map. Syntax DellStateSettings Access Read-write System Resource Map Status Name systemResourceMapStatus Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5 Description Defines the status of this system map.
book.book Page 134 Wednesday, March 6, 2013 12:37 AM System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20.1 Description Defines the System Resource Owner Table entry. Variables in this group reference the System Resource Map index. Syntax SystemResourceOwnerTableEntry Access Not accessible Index systemResourceOwnerchassisIndex, systemResourceOwnerIndex System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.
book.book Page 135 Wednesday, March 6, 2013 12:37 AM System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner. Syntax DellStateSettings Access Read-write System Resource Owner Status Name systemResourceOwnerStatus Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5 Description Defines the status of this system resource owner.
book.book Page 136 Wednesday, March 6, 2013 12:37 AM System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8 Description Defines the description name of the system resource owner. Syntax DellString Access Read-only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
book.book Page 137 Wednesday, March 6, 2013 12:37 AM System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis.
book.book Page 138 Wednesday, March 6, 2013 12:37 AM System Resource I/O Port Status Name systemResourceIOPortStatus Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.5 Description Defines the status of the system resource I/O port. Syntax DellStateSettings Access Read-only System Resource I/O Port Owner Index Reference Name systemResourceIOPortOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6 Description Defines the index to the associated system resource owner in this chassis.
book.book Page 139 Wednesday, March 6, 2013 12:37 AM System Resource I/O Port Ending Address Name systemResourceIOPortEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9 Description Defines the 64 bits of the ending address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only System Resource Memory Table Name systemResourceMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.500.40 Description Defines the System Resource Memory Table.
book.book Page 140 Wednesday, March 6, 2013 12:37 AM System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3 Description Defines the capabilities of this system resource memory.
book.book Page 141 Wednesday, March 6, 2013 12:37 AM System Resource Memory Owner Index Reference Name systemResourceMemoryOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
book.book Page 142 Wednesday, March 6, 2013 12:37 AM System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10 Description Defines the permission flags for the system resource memory. Syntax DellResourceMemoryFlags (See Table 7-4) Access Read-only System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table.
book.book Page 143 Wednesday, March 6, 2013 12:37 AM System Resource Interrupt Index Name systemResourceInterruptIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.2 Description Defines the index (one-based) of this interrupt resource. Syntax DellObjectRange Access Read-only System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt.
book.book Page 144 Wednesday, March 6, 2013 12:37 AM System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.
book.book Page 145 Wednesday, March 6, 2013 12:37 AM System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger (See Table 7-6) Access Read-only System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60 Description Defines the System Resource DMA Table.
book.book Page 146 Wednesday, March 6, 2013 12:37 AM System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA.
book.book Page 147 Wednesday, March 6, 2013 12:37 AM System Resource DMA Owner Index Reference Name systemResourceDMAOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA Share Disposition Name systemResourceDMAShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.
book.book Page 148 Wednesday, March 6, 2013 12:37 AM System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.10 Description Defines the bus mastering capabilities of the system resource DMA. Syntax DellResourceDMABusMaster (See Table 7-7) Access Read-only System Resource Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 7-1.
book.book Page 149 Wednesday, March 6, 2013 12:37 AM Table 7-2. Resource Owner Interface Type (continued) Variable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 7-3.
book.book Page 150 Wednesday, March 6, 2013 12:37 AM Table 7-5. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive(1) The interrupt type is level sensitive. The interrupt type is latched. interruptIsLatched(2) Table 7-6.
book.book Page 151 Wednesday, March 6, 2013 12:37 AM Table 7-8. Resource DMA Transfer Width Variable Name: DellResourceDMATransferWidth Data Type: Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther(1) The DMA transfer width is not one of the following: dmaTransferWidthIsunknown(2) The DMA transfer width is unknown. dmaTransferWidthIs8Bits(3) The DMA transfer width is 8 bits. dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits.
book.
book.book Page 153 Wednesday, March 6, 2013 12:37 AM 8 Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes. NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed.
book.book Page 154 Wednesday, March 6, 2013 12:37 AM Power Unit Table Entry Name powerUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.10.1 Description Defines the Power Unit Table entry. Syntax DellObjectRange Access Read-only Index powerUnitchassisIndex, powerUnitIndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 155 Wednesday, March 6, 2013 12:37 AM Power Unit State Settings Name powerUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.4 Description Defines the state and settings of the power unit. Syntax DellStateSettings Access Read-write Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5 Description Defines the redundancy status of the power unit.
book.book Page 156 Wednesday, March 6, 2013 12:37 AM Power Unit Status Name powerUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.8 Description Defines the status of the power unit in this chassis. Syntax DellStatus Access Read-only Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.
book.book Page 157 Wednesday, March 6, 2013 12:37 AM Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply.
book.book Page 158 Wednesday, March 6, 2013 12:37 AM Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply.
book.book Page 159 Wednesday, March 6, 2013 12:37 AM Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10 Description Defines the index to the associated system power unit in this chassis. Syntax DellObjectRange Access Read-only Power Supply Sensor State Name powerSupplySensorState Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
book.book Page 160 Wednesday, March 6, 2013 12:37 AM Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Voltage Probe Table Name voltageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.20 Description Defines the Voltage Probe Table.
book.book Page 161 Wednesday, March 6, 2013 12:37 AM Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe.
book.book Page 162 Wednesday, March 6, 2013 12:37 AM Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute.
book.book Page 163 Wednesday, March 6, 2013 12:37 AM Name voltageProbeUpperNonRecoverableThreshold Access Read-only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.10 Description Defines the value of the voltage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
book.book Page 164 Wednesday, March 6, 2013 12:37 AM Voltage Probe Lower Critical Threshold Name voltageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.13 Description Defines the value of the voltage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Lower Nonrecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
book.book Page 165 Wednesday, March 6, 2013 12:37 AM Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16 Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute.
book.book Page 166 Wednesday, March 6, 2013 12:37 AM Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Amperage Probe Index Name amperageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.2 Description Defines the index of amperage probes in this chassis.
book.book Page 167 Wednesday, March 6, 2013 12:37 AM Amperage Probe Status Name amperageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5 Description Defines the status of the amperage probe. Syntax DellSigned32BitRange Access Read-only Amperage Probe Reading Name amperageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.6 Description Defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete.
book.book Page 168 Wednesday, March 6, 2013 12:37 AM Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis.
book.book Page 169 Wednesday, March 6, 2013 12:37 AM Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11 Description Defines the user-assigned value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-write Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
book.book Page 170 Wednesday, March 6, 2013 12:37 AM Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.14 Description Defines the value of the amperage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
book.book Page 171 Wednesday, March 6, 2013 12:37 AM AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.40.1 Description Defines the AC Power Switch Table entry.
book.book Page 172 Wednesday, March 6, 2013 12:37 AM AC Power Switch Capabilities Name aCPowerSwitchCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.3 Description Defines the capabilities of this AC power switch. Syntax DellACPowerSwitchCapabilities Access Read-only AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch.
book.book Page 173 Wednesday, March 6, 2013 12:37 AM AC Power Switch Name Name aCPowerSwitchName Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7 Description Defines the name of this AC power switch. Syntax DellString Access Read-only AC Power Switch Redundancy Mode Name aCPowerSwitchRedundancyMode Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.8 Description Defines the redundancy mode of this AC power switch.
book.book Page 174 Wednesday, March 6, 2013 12:37 AM AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.42.1 Description Defines the AC Power Cord Table entry. Syntax ACPowerCordTableEntry Access Not accessible Index aCPowerCordchassisIndex, aCPowerCordIndex AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.1 Description Defines the index (one-based) of the chassis containing this AC power cord.
book.book Page 175 Wednesday, March 6, 2013 12:37 AM AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4 Description Defines the settings of this AC power cord. Syntax DellACPowerCordStateSettings Access Read-write AC Power Cord Status Name aCPowerCordStatus Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.5 Description Defines the status of this AC power cord.
book.book Page 176 Wednesday, March 6, 2013 12:37 AM Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry.
book.book Page 177 Wednesday, March 6, 2013 12:37 AM Battery State Capabilities Name batteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.3 Description Defines the state capabilities of the battery. Syntax DellStateCapabilities Access Read-only Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery.
book.book Page 178 Wednesday, March 6, 2013 12:37 AM Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery. Syntax DellString Access Read-only Power Usage Table Name powerUsageTable Object ID 1.3.6.1.4.1.674.10892.1.600.60 Description Defines the Power Usage Table. Syntax SEQUENCE OF PowerUsageTableEntry Access Not accessible Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.
book.book Page 179 Wednesday, March 6, 2013 12:37 AM Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.2 Description Defines the index (one-based) of the power usage information. Syntax DellObjectRange Access Read-only Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.3 Description Defines the state capabilities of the power usage information.
book.book Page 180 Wednesday, March 6, 2013 12:37 AM Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 181 Wednesday, March 6, 2013 12:37 AM Name powerUsagePeakWatts Description Defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 182 Wednesday, March 6, 2013 12:37 AM Power Usage Peak Amps Start Date Name Name powerUsagePeakAmpsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.13 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute. Syntax DellDateName Access Read-only Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 183 Wednesday, March 6, 2013 12:37 AM Name powerUsageMaxPotentialPower Description Defines the maximum potential power (in Watts) of the system. This is the maximum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Power Usage Power Cap Capabilities Name powerUsagePowerCapCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.17 Description Defines the system power cap capabilities.
book.book Page 184 Wednesday, March 6, 2013 12:37 AM Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 185 Wednesday, March 6, 2013 12:37 AM Name powerProfileTableEntry Access Not accessible Index powerProfileChassisIndex, powerProfileIndex Power Profile Chassis Index Name powerProfileChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Power Profile Index Name powerProfileIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.
book.book Page 186 Wednesday, March 6, 2013 12:37 AM Name powerProfileSetting Syntax DellPowerProfileType Access Read-only Power Profile Custom CPU Management Capabilities Name powerProfileCustomCPUManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.5 Description Defines the custom CPU power and performance management capabilities that are available for the Custom power profile.
book.book Page 187 Wednesday, March 6, 2013 12:37 AM Power Profile Custom Memory Management Setting Name powerProfileCustomMemoryManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.8 Description Defines the custom memory power and performance management setting for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Power Profile Custom Fan Management Capabilities Name powerProfileCustomFanManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 188 Wednesday, March 6, 2013 12:37 AM Table 8-1. Power Supply State Capabilities Unique Variable Name: DellPowerSupplyStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown. onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The power supply’s capabilities are not ready. Table 8-2.
book.book Page 189 Wednesday, March 6, 2013 12:37 AM Table 8-2. Power Supply State Settings Unique (continued) Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value onlineAndPredictiveFail The power supply is online and indicating that it ure(210) has a problem. acPowerAndSwitchAreOn The power supply is online and OK. PowerSupplyIsOnIsOkAnd Online(242) Table 8-3.
book.book Page 190 Wednesday, March 6, 2013 12:37 AM Table 8-3. Power Supply Type Definitions (continued) Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsDC(10) The power supply type is a DC power supply. powerSupplyTypeIsVRM(11) The power supply type is a voltage regulator module (VRM) power supply. Table 8-4.
book.book Page 191 Wednesday, March 6, 2013 12:37 AM Table 8-5. Power Supply Configuration Error Type Variable Name: DellPowerSupplyConfigurationErrorType Data Type: Integer Possible Data Values Meaning of Data Value vendorMismatch(1) The power supply configuration error type is vendor mismatch. revisionMismatch(2) The power supply configuration error type is revision mismatch. processorMissing(3) The power supply configuration error type is processor missing. Table 8-6.
book.book Page 192 Wednesday, March 6, 2013 12:37 AM Table 8-6. Voltage Probe Type (continued) Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsCore(10) The voltage probe type is a core volt probe. voltageProbeTypeIsFLEA(11) The voltage probe type is a FLEA (standby) volt probe. voltageProbeTypeIsBattery(12) The voltage probe type is a battery volt probe.
book.book Page 193 Wednesday, March 6, 2013 12:37 AM Table 8-8. Amperage Probe Definitions Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe.
book.book Page 194 Wednesday, March 6, 2013 12:37 AM Table 8-8. Amperage Probe Definitions (continued) Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIs2Point5Volt(14) The amperage probe type is a 2.5-V amperage probe. amperageProbeTypeIsGTL(15) The amperage probe type is a Gunning Transceiver Logic (GTL) probe. amperageProbeTypeIsDiscrete(16) The amperage probe type is an amperage probe with discrete reading.
book.book Page 195 Wednesday, March 6, 2013 12:37 AM Table 8-10. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown. inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1, with no return. inputSourceCord1ReturnCapable(4) Input source is AC power cord 1, with return.
book.book Page 196 Wednesday, March 6, 2013 12:37 AM Table 8-12. AC Power Switch Redundancy Mode Variable Name: DellACPowerSwitchRedundancyMode Data Type: Integer Possible Data Values Meaning of Data Value nonRedundant(1) The AC power switch is not expecting redundancy. redundant(2) The AC power switch is expecting redundancy. Table 8-13.
book.book Page 197 Wednesday, March 6, 2013 12:37 AM Table 8-15. Battery Reading Variable Name: DellBatteryReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value predictiveFailure(1) Battery sensor detects predictive failure. failed(2) Battery has failed. presenceDetected(4) Battery presence is detected. Table 8-16.
book.book Page 198 Wednesday, March 6, 2013 12:37 AM Table 8-18. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Power profile type is Maximum Performance. osControl(2) Power profile type is OS control. activePowerController(4) Power profile type is Active Power Controller. custom(8) Power profile type is Custom. Table 8-19.
book.book Page 199 Wednesday, March 6, 2013 12:37 AM Table 8-20. Memory Power Performance Management Type Variable Name: DellMemoryPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. mhz1067(4) Memory power and performance is 1067 MHz.
book.
book.book Page 201 Wednesday, March 6, 2013 12:37 AM 9 Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
book.book Page 202 Wednesday, March 6, 2013 12:37 AM Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units.
book.book Page 203 Wednesday, March 6, 2013 12:37 AM Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy.
book.book Page 204 Wednesday, March 6, 2013 12:37 AM Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry.
book.book Page 205 Wednesday, March 6, 2013 12:37 AM Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device.
book.book Page 206 Wednesday, March 6, 2013 12:37 AM Cooling Device Reading Name coolingDeviceReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6 Description Defines either the cooling device’s speed in revolutions per minute (RPM), or the off/on value of the fan. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device.
book.book Page 207 Wednesday, March 6, 2013 12:37 AM Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9 Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
book.book Page 208 Wednesday, March 6, 2013 12:37 AM Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Lower Nonrecoverable Threshold Name coolingDeviceLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
book.book Page 209 Wednesday, March 6, 2013 12:37 AM Cooling Device Probe Capabilities Name coolingDeviceProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.17 Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete.
book.book Page 210 Wednesday, March 6, 2013 12:37 AM Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry. Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex, temperatureProbeIndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
book.book Page 211 Wednesday, March 6, 2013 12:37 AM Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-write Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius.
book.book Page 212 Wednesday, March 6, 2013 12:37 AM Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (See Table 9-4) Access Read-only Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis.
book.book Page 213 Wednesday, March 6, 2013 12:37 AM Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11 Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
book.book Page 214 Wednesday, March 6, 2013 12:37 AM Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
book.book Page 215 Wednesday, March 6, 2013 12:37 AM Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 9-1. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored).
book.book Page 216 Wednesday, March 6, 2013 12:37 AM Table 9-2. Cooling Device Subtype Variable Name: DellCoolingDeviceSubType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther(1) The cooling device subtype is not one of the following: coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is unknown (not known or not monitored). coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a InRPM(3) fan that reads in RPMs.
book.book Page 217 Wednesday, March 6, 2013 12:37 AM Table 9-4. Temperature Probe Type Variable Name: DellTemperatureProbeType Data Type: Integer Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM).
book.
book.book Page 219 Wednesday, March 6, 2013 12:37 AM 10 User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. User Security Table The following object sets up the User Security Table: Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 220 Wednesday, March 6, 2013 12:37 AM User Security Chassis Index Name userSecuritychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.1 Description Defines the user security index (one-based) of this chassis. Syntax DellObjectRange Access Read-only User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index.
book.book Page 221 Wednesday, March 6, 2013 12:37 AM User Security Request Name Name userSecurityRequestName Object ID 1.3.6.1.4.1.674.10892.1.800.1.5 Description Defines a request name used for creating, deleting, and editing users.
book.
book.book Page 223 Wednesday, March 6, 2013 12:37 AM Remote Flash BIOS Group 11 The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table.
book.book Page 224 Wednesday, March 6, 2013 12:37 AM Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system.
book.book Page 225 Wednesday, March 6, 2013 12:37 AM Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5 Description Defines the status of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateStatus Access Read-only Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update.
book.book Page 226 Wednesday, March 6, 2013 12:37 AM Remote Flash BIOS Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 11-1. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown.
book.book Page 227 Wednesday, March 6, 2013 12:37 AM Table 11-3. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer Possible Data Values Meaning of Data Value completionCodeIsOther(1) The completion code status is not one of the following: completionCodeIsUnknown(2) The completion code is unknown (not known or not monitored). completionCodeIsOK(3) This completion code completed successfully.
book.
book.book Page 229 Wednesday, March 6, 2013 12:37 AM 12 Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.
book.book Page 230 Wednesday, March 6, 2013 12:37 AM Pointing Port Table Entry Name pointingPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1 Description Defines the Pointing Port Table entry. Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex, pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 231 Wednesday, March 6, 2013 12:37 AM Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-write Pointing Port Status Name pointingPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5 Description Defines the status of the pointing port.
book.book Page 232 Wednesday, March 6, 2013 12:37 AM Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port.
book.book Page 233 Wednesday, March 6, 2013 12:37 AM Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis.
book.book Page 234 Wednesday, March 6, 2013 12:37 AM Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6 Description Defines the security settings of the keyboard port.
book.book Page 235 Wednesday, March 6, 2013 12:37 AM Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table.
book.book Page 236 Wednesday, March 6, 2013 12:37 AM Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port.
book.book Page 237 Wednesday, March 6, 2013 12:37 AM Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Processor Port Connector Type Name processorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7 Description Defines the connector type of the processor port.
book.book Page 238 Wednesday, March 6, 2013 12:37 AM Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry.
book.book Page 239 Wednesday, March 6, 2013 12:37 AM Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port. Syntax DellStateCapabilities Access Read-only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port.
book.book Page 240 Wednesday, March 6, 2013 12:37 AM Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port. Syntax DellMemoryDevicePortConnectorType (See Table 12-4) Access Read-only Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port.
book.book Page 241 Wednesday, March 6, 2013 12:37 AM Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any).
book.book Page 242 Wednesday, March 6, 2013 12:37 AM Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port.
book.book Page 243 Wednesday, March 6, 2013 12:37 AM Monitor Port Security State Name monitorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.6 Description Defines the security settings of the monitor port. Syntax DellPortSecurityState Access Read-only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port.
book.book Page 244 Wednesday, March 6, 2013 12:37 AM Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table. Syntax IntegerSCSIPortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1 Description Defines the SCSI Port Table entry.
book.book Page 245 Wednesday, March 6, 2013 12:37 AM SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port.
book.book Page 246 Wednesday, March 6, 2013 12:37 AM SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port. Syntax DellSCSIPortConnectorType (See Table 12-6) Access Read-only SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port.
book.book Page 247 Wednesday, March 6, 2013 12:37 AM Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex, parallelPortIndex Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 248 Wednesday, March 6, 2013 12:37 AM Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port.
book.book Page 249 Wednesday, March 6, 2013 12:37 AM Parallel Port Name Name parallelPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8 Description Defines the name of the parallel port. Syntax DellString Access Read-only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port.
book.book Page 250 Wednesday, March 6, 2013 12:37 AM Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13 Description Defines if direct memory access (DMA) is supported by the parallel port.
book.book Page 251 Wednesday, March 6, 2013 12:37 AM Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis.
book.book Page 252 Wednesday, March 6, 2013 12:37 AM Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6 Description Defines the security settings of the serial port.
book.book Page 253 Wednesday, March 6, 2013 12:37 AM Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port.
book.book Page 254 Wednesday, March 6, 2013 12:37 AM Universal Serial Bus (USB) Port Table Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry.
book.book Page 255 Wednesday, March 6, 2013 12:37 AM USB Port State Capabilities Name uSBPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3 Description Defines the capabilities of the USB port. Syntax DellStateCapabilities Access Read-only USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port.
book.book Page 256 Wednesday, March 6, 2013 12:37 AM USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only USB Port Name Name uSBPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8 Description Defines the name of the USB port. Syntax DellString Access Read-only USB Port BIOS Connector Type Name uSBPortBIOSConnectorType Object ID 1.3.6.
book.book Page 257 Wednesday, March 6, 2013 12:37 AM Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 12-1. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown.
book.book Page 258 Wednesday, March 6, 2013 12:37 AM Table 12-2. Keyboard Port Connector Types Variable Name: DellKeyboardPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The keyboard port connector type is not one of the following: connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN.
book.book Page 259 Wednesday, March 6, 2013 12:37 AM Table 12-3. Processor Port Connector Types Variable Name: DellProcessorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The processor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The processor port connector type is unknown. connectorPortTypeIsDaughterdBoard(3) The processor port connector type is a daughter board.
book.book Page 260 Wednesday, March 6, 2013 12:37 AM Table 12-4. Memory Device Port Connector Types Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsOther(1) The memory device port connector type is not one of the following: connectorPortTypeIsUnknown(2) The memory device port connector type is unknown. connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM).
book.book Page 261 Wednesday, March 6, 2013 12:37 AM Table 12-4. Memory Device Port Connector Types (continued) Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsRIMM(12) The memory device port connector type is a Rambus Inline Memory Module (RIMM). connectorPortTypeIsSODIMM(13) The memory device port connector type is a small outline, dual in-line memory module (SODIMM).
book.book Page 262 Wednesday, March 6, 2013 12:37 AM Table 12-6. SCSI Port Connector Types Variable Name: DellSCSIPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The SCSI port connector type is not one of the following: connectorPortTypeIsUnknown(2) The SCSI port connector type is unknown. connectorPortTypeIsDIN25pin(3) The SCSI port connector type is a DIN 25-pin.
book.book Page 263 Wednesday, March 6, 2013 12:37 AM 13 Device Group The Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover information about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.
book.book Page 264 Wednesday, March 6, 2013 12:37 AM Pointing Device Table Name pointingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.10 Description Defines the Pointing Device Table. This group of objects references the Pointing Port Index (See Section 12). Syntax SEQUENCE OF PointingDeviceTableEntry Access Not accessible Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry.
book.book Page 265 Wednesday, March 6, 2013 12:37 AM Pointing Device State Capabilities Name pointingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.3 Description Defines the capabilities of the pointing device. Syntax DellStateCapabilities Access Read-only Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4 Description Defines the state of the pointing device.
book.book Page 266 Wednesday, March 6, 2013 12:37 AM Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device. Syntax DellPointingDeviceType (See Table 13-1) Access Read-only Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.8 Description Defines the number of buttons on the pointing device.
book.book Page 267 Wednesday, March 6, 2013 12:37 AM Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis.
book.book Page 268 Wednesday, March 6, 2013 12:37 AM Keyboard Device Status Name keyboardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5 Description Defines the status of the keyboard device. Syntax DellStatus Access Read-only Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis.
book.book Page 269 Wednesday, March 6, 2013 12:37 AM Processor Device Table Name processorDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.30 Description Defines the Processor Device Table. Syntax SEQUENCE OF ProcessorDeviceTableEntry Access Not accessible Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry.
book.book Page 270 Wednesday, March 6, 2013 12:37 AM Processor Device State Capabilities Name processorDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.3 Description Defines the capabilities of the processor device. Syntax DellStateCapabilities Access Read-only Processor Device State Settings Name processorDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.4 Description Defines the state of the processor device.
book.book Page 271 Wednesday, March 6, 2013 12:37 AM Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Table 13-4) Access Read-only Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device.
book.book Page 272 Wednesday, March 6, 2013 12:37 AM Processor Device Maximum Speed Name processorDeviceMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.11 Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
book.book Page 273 Wednesday, March 6, 2013 12:37 AM Processor Device Voltage Name processorDeviceVoltage Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.14 Description Defines the voltage powering the processor device in millivolts. A zero (0) indicates the speed is unknown. Syntax DellSigned32BitRange Access Read-only Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
book.book Page 274 Wednesday, March 6, 2013 12:37 AM Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18 Description Defines the number of processor cores enabled for the processor device.
book.book Page 275 Wednesday, March 6, 2013 12:37 AM Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1.
book.book Page 276 Wednesday, March 6, 2013 12:37 AM Processor Device Extended Settings Name processorDeviceExtendedSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22 Description This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
book.book Page 277 Wednesday, March 6, 2013 12:37 AM Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Name processorDeviceStatusTable Object ID 1.3.6.1.4.1.674.10892.1.1100.32 Description Defines the Processor Device Status Table.
book.book Page 278 Wednesday, March 6, 2013 12:37 AM Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
book.book Page 279 Wednesday, March 6, 2013 12:37 AM Processor Device Status Reading Name processorDeviceStatusReading Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6 Description Defines the reading of the processor device status probe. Syntax DellProcessorDeviceStatusReading Access Read-only Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe.
book.book Page 280 Wednesday, March 6, 2013 12:37 AM Cache Device Table Entry Name cacheDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1 Description Defines the Cache Device Table entry. Syntax CacheDeviceTableEntry Access Not accessible Index cacheDevicechassisIndex, cacheDeviceIndex Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 281 Wednesday, March 6, 2013 12:37 AM Cache Device State Settings Name cacheDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.4 Description Defines the state of the cache device. Syntax DellStateSettings Access Read-write Cache Device Status Name cacheDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5 Description Defines the status of the cache device.
book.book Page 282 Wednesday, March 6, 2013 12:37 AM Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Table 13-13) Access Read-only Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9 Description Defines the status state of the cache device.
book.book Page 283 Wednesday, March 6, 2013 12:37 AM Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12 Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB.
book.book Page 284 Wednesday, March 6, 2013 12:37 AM Cache Device Is Socketed Name cacheDeviceIsSocketed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.16 Description Defines if the cache device is socketed. Syntax DellBoolean Access Read-only Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device.
book.book Page 285 Wednesday, March 6, 2013 12:37 AM Cache Device Current Type Name cacheDeviceCurrentType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20 Description Defines the current type of SRAM for the cache device. Syntax DellCacheDeviceSRAMType (See Table 13-14) Access Read-only Memory Device Table Name memoryDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.50 Description Defines the Memory Device Table.
book.book Page 286 Wednesday, March 6, 2013 12:37 AM Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis. Syntax DellObjectRange Access Read-only Memory Device State Capabilities Name memoryDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device.
book.book Page 287 Wednesday, March 6, 2013 12:37 AM Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device.
book.book Page 288 Wednesday, March 6, 2013 12:37 AM Memory Device Error Count NOTE: "Memory Device Failure Modes" on page 291 has now replaced this attribute. Memory Device Error Count should no longer be used. If you use the Memory Device Error Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
book.book Page 289 Wednesday, March 6, 2013 12:37 AM Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.12 Description Defines the form factor of the memory device. Syntax DellMemoryDeviceFormFactor (See Table 13-15) Access Read-only Memory Device Set Name memoryDeviceSet Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.13 Description Defines if the memory device is a part of a set. A zero (0) indicates that this device is not part of a set.
book.book Page 290 Wednesday, March 6, 2013 12:37 AM Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device.
book.book Page 291 Wednesday, March 6, 2013 12:37 AM Memory Device Uncorrectable Memory Event Count NOTE: "Memory Device Failure Modes" on page 291 has now replaced this attribute. Memory Device Uncorrectable Memory Event Count should no longer be used. If you use the Memory Device Uncorrectable Memory Event Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceMultiBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
book.book Page 292 Wednesday, March 6, 2013 12:37 AM Memory Device Part Number Name Name memoryDevicePartNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.22 Description Defines the manufacturer's part number for the memory device. Syntax DellString Access Read-only Memory Device Serial Number Name Name memoryDeviceSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.23 Description Defines the serial number of the memory device.
book.book Page 293 Wednesday, March 6, 2013 12:37 AM Memory Device Mapped Address Table Name memoryDeviceMappedAddressTable Object ID 1.3.6.1.4.1.674.10892.1.1100.60 Description Defines the Memory Device Mapped Address Table. Syntax SEQUENCE OF MemoryDeviceMappedAddressTableEntry Access Not accessible Memory Device Mapped Address Table Entry Name memoryDeviceMappedAddressTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1 Description Defines the Memory Device Mapped Address Table entry.
book.book Page 294 Wednesday, March 6, 2013 12:37 AM Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis. Syntax DellObjectRange Access Read-only Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
book.book Page 295 Wednesday, March 6, 2013 12:37 AM Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
book.book Page 296 Wednesday, March 6, 2013 12:37 AM Memory Device Mapped Address Interleave Depth Name memoryDeviceMappedAddressInterleaveDepth Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.9 Description Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address.
book.book Page 297 Wednesday, March 6, 2013 12:37 AM Generic Device Table Entry Name genericDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1 Description Defines the Generic Device Table entry. Syntax GenericDeviceTableEntry Access Not accessible Index genericDevicechassisIndex, genericDeviceIndex Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 298 Wednesday, March 6, 2013 12:37 AM Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device. Syntax DellStateSettings Access Read-write Generic Device Status Name genericDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5 Description Defines the status of the generic device.
book.book Page 299 Wednesday, March 6, 2013 12:37 AM Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.
book.book Page 300 Wednesday, March 6, 2013 12:37 AM PCI Device Index Name pCIDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2 Description Defines the index (one-based) of the PCI device in this chassis. Syntax DellObjectRange Access Read-only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device.
book.book Page 301 Wednesday, March 6, 2013 12:37 AM PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.6 Description Defines the index number of the system slot that this PCI device is in. Syntax DellObjectRange Access Read-only PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis.
book.book Page 302 Wednesday, March 6, 2013 12:37 AM PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.10 Description Defines the bus speed in MHz of the PCI device in this chassis. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11 Description Defines whether the PCI device in this chassis has detected a fault.
book.book Page 303 Wednesday, March 6, 2013 12:37 AM PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only PCI Device Configuration Space Index Name pCIDeviceConfigurationSpaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.
book.book Page 304 Wednesday, March 6, 2013 12:37 AM PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to.
book.book Page 305 Wednesday, March 6, 2013 12:37 AM PCI Device Configuration Space Function Number Name pCIDeviceConfigurationSpaceFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9 Description Defines the function number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.
book.book Page 306 Wednesday, March 6, 2013 12:37 AM Network Device Chassis Index Name networkDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.1 Description Defines the index (one-based) of the chassis that contains the network device. Syntax DellObjectRange Access Read-only Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device.
book.book Page 307 Wednesday, March 6, 2013 12:37 AM Network Device Description Name Name networkDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5 Description Defines the description of the network device. Syntax DellString Access Read-only Network Device Product Name Name networkDeviceProductName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.6 Description Defines the product name of the network device.
book.book Page 308 Wednesday, March 6, 2013 12:37 AM Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10 Description Defines the version of the driver for the network device.
book.book Page 309 Wednesday, March 6, 2013 12:37 AM Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13 Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
book.book Page 310 Wednesday, March 6, 2013 12:37 AM Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17 Description Defines the PCI bus number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device.
book.book Page 311 Wednesday, March 6, 2013 12:37 AM Network Device Base IO Port Address Name networkDeviceBaseIOPortAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.21 Description Defines the base input/outport port address of the network device. Syntax DellUnsigned32BitRange Access Read-only Network Device Teaming Flags Name networkDeviceTeamingFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22 Description Defines the teaming features of the network device.
book.book Page 312 Wednesday, March 6, 2013 12:37 AM Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (see Table 13-23) Access Read-only Network Device RDMA Enabled Name networkDeviceRDMAEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
book.book Page 313 Wednesday, March 6, 2013 12:37 AM Managed System Services Device Table Name managedSystemServicesDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax Sequence of ManagedSystemServicesDeviceTable Access Not accessible Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.100.
book.book Page 314 Wednesday, March 6, 2013 12:37 AM Managed System Services Device Index Name managedSystemServicesDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.2 Description Defines the index (one-based) of the managed system services device. Syntax DellObjectRange Access Read-only Managed System Services Device Status Name managedSystemServicesDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3 Description Defines the status of the managed system services device.
book.book Page 315 Wednesday, March 6, 2013 12:37 AM Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.5 Description Defines whether storage is present on the managed system services device. Syntax DellBoolean Access Read-only Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.
book.book Page 316 Wednesday, March 6, 2013 12:37 AM Name sdCardUnitTableEntry Index sdCardUnitChassisIndex, sdCardUnitIndex SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit. Syntax DellObjectRange Access Read-only SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.
book.book Page 317 Wednesday, March 6, 2013 12:37 AM Name sdCardUnitStateSettings Description Defines the state settings of the SD Card unit. Syntax DellStateSettings Access Read-only SD Card Unit Redundancy Status Name sdCardUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5 Description Defines the redundancy status of the SD Card unit. Syntax DellStatusRedundancy Access Read-only SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.
book.book Page 318 Wednesday, March 6, 2013 12:37 AM SD Card Unit Status Name sdCardUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.8 Description Defines the status of the SD Card unit. Syntax DellStatus Access Read-only SD Card Device Table Name sdCardDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.112 Description Defines the SD Card Device Table.
book.book Page 319 Wednesday, March 6, 2013 12:37 AM Name sdCardDeviceChassisIndex Access Read-only SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device. Syntax DellObjectRange Access Read-only SD Card Device Status Name sdCardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.3 Description Defines the status of the SD Card device.
book.book Page 320 Wednesday, March 6, 2013 12:37 AM Name sdCardDeviceConfigCapabilities Access Read-only SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device. Syntax DellSDCardDeviceConfigSettings Access Read-only SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
book.book Page 321 Wednesday, March 6, 2013 12:37 AM Name sdCardDeviceCardState Access Read-only SD Card Device Card Storage Size Name sdCardDeviceCardStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.10 Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device. Syntax DellUnsigned32BitRange Access Read-only SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
book.book Page 322 Wednesday, March 6, 2013 12:37 AM SD Card Device Card Available Storage Size Name sdCardDeviceCardAvailableStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.12 Description Defines the available storage size in MB (megabytes) of the SD card for the SD card device. Syntax DellSigned32BitRange Access Read-only SD Card Device Card Licensed Name sdCardDeviceCardLicensed Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
book.book Page 323 Wednesday, March 6, 2013 12:37 AM Table 13-1. Pointing Device Type (continued) Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsATouchPad(7) Device type is a touch pad. Table 13-2. Processor Device Status State Variable Name: DellProcessorDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Processor device type is not one of the following: unknown(2) Device type is unknown.
book.book Page 324 Wednesday, March 6, 2013 12:37 AM Table 13-3. Processor Device Status Reading (continued) Variable Name: DellProcessorDeviceStatusReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value processorDisabled(256) The processor is disabled terminatorPresent(512) The terminator is Present processorThrottled(1024) The processor is throttled Table 13-4.
book.book Page 325 Wednesday, March 6, 2013 12:37 AM Table 13-5. Processor Upgrade Information Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsOther(1) The upgrade device type is not one of the following: processorUpgradeIsUnknown(2) Upgrade device type is unknown. processorUpgradeIsByDaughterBoard(3) Upgrade device is on a daughter board.
book.book Page 326 Wednesday, March 6, 2013 12:37 AM Table 13-5. Processor Upgrade Information (continued) Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsBySocket939(18) Upgrade is by Socket 939. processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604. processorUpgradeIsBySocketLGA771(20) Upgrade is by Socket LGA771. processorUpgradeIsBySocketLGA775(21) Upgrade is by Socket LGA775.
book.book Page 327 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIs80287(8) The processor family is 80287. deviceFamilyIs80387(9) The processor family is 80387. deviceFamilyIs80487(10) The processor family is 80487. deviceFamilyIsPentium(11) The processor family is Intel Pentium. deviceFamilyIsPentiumPro(12) The processor family is Pentium Pro.
book.book Page 328 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsK6-2Plus(31) The processor family is K6-2+. deviceFamilyIsPowerPC(32) The processor family is Power PC. deviceFamilyIsPowerPC601(33) The processor family is Power PC 601. deviceFamilyIsPowerPC603(34) The processor family is Power PC 603.
book.book Page 329 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDTurionIIUltra The processor family is AMD Turion II DualMobileM(56) Ultra Dual-Core Mobile M Processor Family. deviceFamilyIsAMDTurionIIDualM The processor family is AMD Turion II obileM(57) Dual-Core Mobile M Processor Family.
book.book Page 330 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi. deviceFamilyIsUltraSPARCIII(87) The processor family is UltraSPARC III. deviceFamilyIsUltraSPARCIIIi (88) The processor family is UltraSPARC IIIi. deviceFamilyIs68040(96) The processor family is 68040 Family.
book.book Page 331 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAthlon64X2Dual The processor family is AMD Athlon Core(136) 64 X2 Dual-Core. deviceFamilyIsAMDTurion64X2Mob The processor family is AMD Turion 64 ile(137) X2 Mobile Technology. deviceFamilyIsQuadCoreAMDOpter The processor family is Quad-Core on(138) AMD Opteron.
book.book Page 332 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n3000(162) Xeon processor 3000 Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n5300(163) Intel Xeon processor 5300 Series.
book.book Page 333 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsM2(177) The processor family is M2. deviceFamilyIsIntelPentium4HT (179) The processor family is Intel Pentium 4 HT processor. deviceFamilyIsAS400(180) The processor family is AS400. deviceFamilyIsAMDAthlonXP(182) The processor family is AMD Athlon XP.
book.book Page 334 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2 eMobile(195) Extreme mobile processor. deviceFamilyIsIntelCore2DuoMob The processor family is Intel Core2 ile(196) Duo mobile processor. deviceFamilyIsIntelCore2SoloMo The processor family is Intel Core2 bile(197) Solo mobile processor.
book.book Page 335 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n3xxx(215) Xeon processor 3xxx Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n3xxx(216) Intel Xeon processor 3xxx Series. deviceFamilyIsVIANano(217) The processor family is VIA Nano.
book.book Page 336 Wednesday, March 6, 2013 12:37 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDPhenomII(236) The processor family is AMD Phenom II. deviceFamilyIsAMDAthlonII(237) The processor family is AMD Athlon II. deviceFamilyIsSixCoreAMDOptero The processor family is Six-Core AMD n(238) Opteron. deviceFamilyIsAMDSempronM(239) The processor family is AMD Sempron M.
book.book Page 337 Wednesday, March 6, 2013 12:37 AM Table 13-8. Cache Device Level Variable Name: DellCacheDeviceLevel Data Type: Integer Possible Data Values Meaning of Data Value deviceLevelIsOther(1) Device level is not one of the following: deviceLevelIsUnknown(2) Device level is unknown. deviceLevelIsPrimary(3) Device level is primary. deviceLevelIsSecondary(4) Device level is secondary. deviceLevelIsTertiary(5) Device level is tertiary. Table 13-9.
book.book Page 338 Wednesday, March 6, 2013 12:37 AM Table 13-10. Cache Device Status State Variable Name: DellCacheDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 13-11.
book.book Page 339 Wednesday, March 6, 2013 12:37 AM Table 13-12. Cache Device Associativity (continued) Variable Name: DellCacheDeviceAssociativity Data Type: Integer Possible Data Values Meaning of Data Value deviceAssociativityIsUnknown(2) Device associativity is unknown. deviceAssociativityIsDirectMapped(3) Device is direct mapped. deviceAssociativityIsTwoWaySetAsso ciative(4) Device is two-way set associative. deviceAssociativityIsFourWaySetAsso Device is four-way set ciative(5) associative.
book.book Page 340 Wednesday, March 6, 2013 12:37 AM Table 13-13. Cache Device Location Variable Name: DellCacheDeviceLocation Data Type: Integer Possible Data Values Meaning of Data Value deviceLocationIsOther(1) Device location is not one of the following: deviceLocationIsUnknown(2) Device location is unknown. deviceLocationIsInternal(3) Device location is internal. deviceLocationIsExternal(4) Device location is external. Table 13-14.
book.book Page 341 Wednesday, March 6, 2013 12:37 AM Table 13-15. Memory Device Type Form Factor (continued) Variable Name: DellMemoryDeviceFormFactor Data Type: Integer Possible Data Values Meaning of Data Value deviceFormFactorIsUnknown(2) Device form factor is unknown. deviceFormFactorIsSIMM(3) Device form factor is SIMM. deviceFormFactorIsSIP(4) Device form factor is SIP. deviceFormFactorIsAChip(5) Device form factor is a chip. deviceFormFactorIsDIP(6) Device form factor is DIP.
book.book Page 342 Wednesday, March 6, 2013 12:37 AM Table 13-16. Memory Device Type (continued) Variable Name: DellMemoryDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsVRAM(5) Device type is VRAM. deviceTypeIsSRAM(6) Device type is SRAM. deviceTypeIsRAM(7) Device type is RAM. deviceTypeIsROM(8) Device type is ROM. deviceTypeIsFLASH(9) Device type is FLASH. deviceTypeIsEEPROM(10) Device type is EEPROM. deviceTypeIsFEPROM(11) Device type is FEPROM.
book.book Page 343 Wednesday, March 6, 2013 12:37 AM Table 13-17. Memory Device Type Details Variable Name: DellMemoryDeviceTypeDetails Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeDetailIsOther(2) The detailed device type is not one of the following: deviceTypeDetailIsUnknown(4) The detailed device type is unknown. deviceTypeDetailIsFastPaged (8) The detailed device type is fast paged. deviceTypeDetailIsStaticColum The detailed device type is static column.
book.book Page 344 Wednesday, March 6, 2013 12:37 AM Table 13-18. Generic Device Type Variable Name: DellGenericDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAVideoDevice(3) Device type is a video. deviceTypeIsASCSIController(4) Device type is a SCSI controller. deviceTypeIsAnEthernetDevice(5) Device type is Ethernet.
book.book Page 345 Wednesday, March 6, 2013 12:37 AM Table 13-19. Memory Device Failure Modes (continued) Variable Name: DellMemoryDeviceFailureModes Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value eccSingleBitCorrectionLoggingDisabled(8) Correctable Memory Event logging for memory device has been disabled. deviceDisabledBySpareActivation(16) Memory device is disabled because of spare memory activation. Table 13-20.
book.book Page 346 Wednesday, March 6, 2013 12:37 AM Table 13-21. Network Device Teaming Flags Variable Name: DellNetworkDeviceTeamingFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value undefined(0) Teaming flags are undefined. noTeam(1) Device is not part of any team. teamingEnabled(2) Teaming is enabled. adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode.
book.book Page 347 Wednesday, March 6, 2013 12:37 AM Table 13-23. Network Device RDMA Capability Flags Variable Name: DellNetworkDeviceRDMACapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for RDMA capability is not supported. unknown(1) Querying for RDMA capability is supported but query returned an error. available(2) Device has RDMA capability.
book.book Page 348 Wednesday, March 6, 2013 12:37 AM Table 13-25. Managed System Services Device Type Variable Name: DellManagedSystemServicesDeviceType Data Type: Integer Possible Data Values Meaning of Data Value baseDevice(0) Device type is base device. optionalDevice(1) Device type is optional device. Table 13-26. SD Card Device Type Variable Name: DellSDCardDeviceType Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device type is other.
book.book Page 349 Wednesday, March 6, 2013 12:37 AM Table 13-28. SD Card Device Config Settings Variable Name: DellSDCardDeviceConfigSettings Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following settings. sdEnabled(1) SD media is enabled. vFlashEnabled(2) Virtual Flash (vFlash) is enabled. Table 13-29.
book.book Page 350 Wednesday, March 6, 2013 12:37 AM Variable Name: DellSDCardDeviceCardLicensed Data Type: Integer Possible Data Values Meaning of Data Value licensed(1) SD card is licensed by system vendor. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected. standby(256) Device is in standby mode.
book.book Page 351 Wednesday, March 6, 2013 12:37 AM Slot Group 14 The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table.
book.book Page 352 Wednesday, March 6, 2013 12:37 AM System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis.
book.book Page 353 Wednesday, March 6, 2013 12:37 AM System Slot Status Name systemSlotStatus Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5 Description Defines the status of the system slot. Syntax DellStatus Access Read-only System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.
book.book Page 354 Wednesday, March 6, 2013 12:37 AM System Slot Length Name systemSlotLength Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9 Description Defines the length of the system slot. Syntax DellSystemSlotLength (See Table 14-5) Access Read-only System Slot Slot ID Name systemSlotSlotID Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.10 Description Defines the slot identification number of the system slot. A zero (0) indicates that the slot is embedded on the motherboard.
book.book Page 355 Wednesday, March 6, 2013 12:37 AM System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only System Slot Hot-Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
book.book Page 356 Wednesday, March 6, 2013 12:37 AM Table 14-1. System Slot State Capabilities (continued) Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugCanSignal The system slot attention state Attention(8) (and corresponding LED) can be set. systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can PowerFault(16) be detected due to a short or overcurrent.
book.book Page 357 Wednesday, March 6, 2013 12:37 AM Table 14-2. System Slot State Settings Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) can be powered on.
book.book Page 358 Wednesday, March 6, 2013 12:37 AM Table 14-2. System Slot State Settings (continued) Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotSupportsCard16(1024) The system slot supports PC Card-16. systemSlotSupportsCardBus(2048) The system slot supports CardBus. systemSlotSupportsZoomVideo(4096) The system slot supports zoom video. systemSlotSupportsModemRingResume The system slot supports modem (8192) ring resume.
book.book Page 359 Wednesday, March 6, 2013 12:37 AM Table 14-3. System Slot Type Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsOther(1) The system slot type is not one of following: systemSlotIsUnknown(2) The system slot type is unknown. systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA). systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA).
book.book Page 360 Wednesday, March 6, 2013 12:37 AM Table 14-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPC98C20(18) The system slot is a PC-98/C20. systemSlotIsPC98C24(19) The system slot is a PC-98/C24. systemSlotIsPC98E(20) The system slot type is PC-98/E. systemSlotIsPC98LocalBus(21) The system slot type is a PC-98 local bus. systemSlotIsPC98Card(22) The system slot type is a PC-98 card.
book.book Page 361 Wednesday, March 6, 2013 12:37 AM Table 14-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express Gen 2 x4. systemSlotIsPCIExpressGen2X8(175) The system slot type is PCI Express Gen 2 x8. systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express Gen 2 x16. Table 14-4.
book.book Page 362 Wednesday, March 6, 2013 12:37 AM Table 14-6. System Slot Category Variable Name: DellSystemSlotCategory Data Type: Integer Possible Data Values Meaning of Data Value systemSlotCategoryIsOther(1) The system slot category is not one of following: systemSlotCategoryIsUnknown(2) The system slot category is unknown. systemSlotCategoryIsBusConnector(3) The system slot is a bus connector. systemSlotCategoryIsPCMCIA(4) The system slot category is PCMCIA.
book.book Page 363 Wednesday, March 6, 2013 12:37 AM Table 14-7. Hot-Plug Bus Width (continued) Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIs12xOrx12(12) The system slot bus width is 12x or x12. busWidthIs16xOrx16(13) The system slot bus width is 16x or x16. busWidthIs32xOrx32(14) The system slot bus width is 32x or x32. NOTE: System slot bus width of type n bits are for parallel buses such as PCI.
book.
book.book Page 365 Wednesday, March 6, 2013 12:37 AM 15 Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
book.book Page 366 Wednesday, March 6, 2013 12:37 AM The following object sets up the Physical Memory Array Table: Name physicalMemoryArrayTable Object ID 1.3.6.1.4.1.674.10892.1.1300.10 Description Defines the Physical Memory Array Table. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry.
book.book Page 367 Wednesday, March 6, 2013 12:37 AM Physical Memory Array State Capabilities Name physicalMemoryArrayStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3 Description Defines the capabilities of the physical memory array. Syntax DellStateCapabilities Access Read-only Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array.
book.book Page 368 Wednesday, March 6, 2013 12:37 AM Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7 Description Defines the ECC type used by the physical memory array. Syntax DellPhysicalMemoryArrayECCType (See Table 15-2) Access Read-only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
book.book Page 369 Wednesday, March 6, 2013 12:37 AM Physical Memory Array In Use Number Sockets Name physicalMemoryArrayInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11 Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
book.book Page 370 Wednesday, March 6, 2013 12:37 AM Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndex Reference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.15 Description Defines the index to the associated Redundant Memory Unit in this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses.
book.book Page 371 Wednesday, March 6, 2013 12:37 AM Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis.
book.book Page 372 Wednesday, March 6, 2013 12:37 AM Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis.
book.book Page 373 Wednesday, March 6, 2013 12:37 AM Physical Memory Array Mapped Partition Width Name physicalMemoryArrayMappedPartitionWidth Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.9 Description Defines the number of memory devices that form a single row in the memory array mapped address. A zero (0) indicates that the number is unknown.
book.book Page 374 Wednesday, March 6, 2013 12:37 AM Physical Memory Configuration Chassis Index Name physicalMemoryConfigChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory configuration. Syntax DellObjectRange Access Read-only Physical Memory Configuration Index Name physicalMemoryConfigIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
book.book Page 375 Wednesday, March 6, 2013 12:37 AM Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration. Syntax DellStatus Access Read-only Physical Memory Configuration Redundant Capabilities Name physicalMemoryConfigRedundantCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.6 Description Defines the redundant capabilities of the physical memory.
book.book Page 376 Wednesday, March 6, 2013 12:37 AM Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9 Description Defines the Memory Operating Mode settings of the physical memory. Syntax DellPhysicalMemoryConfigMOMSettings Access Read-only Physical Memory Logging Table This table defines the conditions for logging system memory events.
book.book Page 377 Wednesday, March 6, 2013 12:37 AM Physical Memory Logging Chassis Index Name physicalMemoryLoggingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory logging. Syntax DellObjectRange Access Read-only Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.
book.book Page 378 Wednesday, March 6, 2013 12:37 AM Physical Memory Logging Status Name physicalMemoryLoggingStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.5 Description Defines the status of the physical memory logging. Syntax DellStatus Access Read-only Redundant Memory Unit Table This table reports the status of redundant memory within a particular system chassis. The following object sets up the Redundant Memory Unit Table: Name redundantMemoryUnitTable Object ID 1.3.6.1.4.1.674.
book.book Page 379 Wednesday, March 6, 2013 12:37 AM Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex, redundantMemoryUnitIndex Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
book.book Page 380 Wednesday, March 6, 2013 12:37 AM Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit.
book.book Page 381 Wednesday, March 6, 2013 12:37 AM Physical Memory Card Table This table defines the name of the memory card, the total number of device slots present on the memory card, and the number of memory device slots in use on the memory card. The following objects set up the Physical Memory Card Table: Physical Memory Card Table Name physicalMemoryCardTable Object ID 1.3.6.1.4.1.674.10892.1.1300.60 Description Defines the Physical Memory Card Table.
book.book Page 382 Wednesday, March 6, 2013 12:37 AM Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card. Syntax DellObjectRange Access Read-only Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3 Description Defines the state capabilities of the Physical Memory Card.
book.book Page 383 Wednesday, March 6, 2013 12:37 AM Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card.
book.book Page 384 Wednesday, March 6, 2013 12:37 AM Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.
book.book Page 385 Wednesday, March 6, 2013 12:37 AM Table 15-1. Physical Memory Array Location (continued) Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option card. memoryArrayLocationIsProprietary(9) The memory array location is a proprietary option card.
book.book Page 386 Wednesday, March 6, 2013 12:37 AM Table 15-2. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity.
book.book Page 387 Wednesday, March 6, 2013 12:37 AM Table 15-4. Physical Memory Configuration State Settings Variable Name: DellPhysicalMemoryConfigStateSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state settings. unknown(1) State settings are unknown. enabled(2) Object is disabled (offline) 0, or enabled (online) 1. notReady(4) Object not ready.
book.book Page 388 Wednesday, March 6, 2013 12:37 AM Table 15-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory settings enabled. unknown(1) Redundant settings are unknown. The following redundant settings are mutually exclusive: spareEnabled(2) Spare redundant memory feature is enabled.
book.book Page 389 Wednesday, March 6, 2013 12:37 AM Table 15-8. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) Logging is disabled (0), or enabled (1).
book.
book.book Page 391 Wednesday, March 6, 2013 12:37 AM BIOS Setup Control Group 16 Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
book.book Page 392 Wednesday, March 6, 2013 12:37 AM Name biosSetUpControlTable Access Not accessible BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1 Description Defines the BIOS Control Device Table entry. Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 393 Wednesday, March 6, 2013 12:37 AM Name bSUCpointingDeviceControlSettings Syntax DellStateSettings Access Read-write BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 394 Wednesday, March 6, 2013 12:37 AM Name bSUCnumLockControlSettings Syntax DellStateSettings Access Read-only BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.8 Description Defines the status of the numeric lock. Syntax DellStatus Access Read-only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 395 Wednesday, March 6, 2013 12:37 AM Name bSUCprocessorSerialNumberControlSettings Syntax DellStateSettings Access Read-only BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number.
book.book Page 396 Wednesday, March 6, 2013 12:37 AM Name bSUCspeakerControlSettingsUnique Syntax DellSpeakerControlSettingsUnique (See Table 16-2) Access Read-only BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 397 Wednesday, March 6, 2013 12:37 AM Name bSUCnIFwakeonLanControlSettingsUnique Description Defines the state of the NIF Wakeup on LAN. Syntax DellNIFwakeonLanControlSettingsUnique (See Table 16-4) Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Status Name bSUCnIFwakeonLanControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.20 Description Defines the status of the NIF Wakeup on LAN.
book.book Page 398 Wednesday, March 6, 2013 12:37 AM Name DellBootSequenceControlSettingsUnique Description Defines the state of the boot sequence. Syntax DellBootSequenceControlSettingsUnique (See Table 16-6) Access Read-only BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.24 Description Defines the status of the boot sequence.
book.book Page 399 Wednesday, March 6, 2013 12:37 AM BIOS Setup Control Administrator Password Control Settings Unique Name bSUCadministratorPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.27 Description Defines the settings for administrator password control. Syntax DellBIOSPasswordControlSettingsUnique (See Table 16-9) Access Read-write BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.
book.book Page 400 Wednesday, March 6, 2013 12:37 AM BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPasswordControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.31 Description Defines the capabilities of user password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 401 Wednesday, March 6, 2013 12:37 AM BIOS Setup Control User Password New Password Name Name bSUCuserPasswordNewPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.35 Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user password immediately preceding this password change.
book.book Page 402 Wednesday, March 6, 2013 12:37 AM BIOS Setup Control TPM Security Control Name Name bSUCtpmSecurityControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.39 Description Defines the BIOS setup control name of Trusted Platform Module (TPM) security. Syntax DellString Access Read-only SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table.
book.book Page 403 Wednesday, March 6, 2013 12:37 AM SCSI Control Index Name sCSIControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.2 Description Defines the index (one-based) of the SCSI controller in this chassis. Syntax DellObjectRange Access Read-only SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3 Description Defines the capabilities of the SCSI controller.
book.book Page 404 Wednesday, March 6, 2013 12:37 AM SCSI Control Name Name sCSIControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.6 Description Defines the setup BIOS name of the SCSI controller. Syntax DellString Access Read-only Parallel Port Control Table Name parallelPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.30 Description Defines the Parallel Port Control Table.
book.book Page 405 Wednesday, March 6, 2013 12:37 AM Parallel Port Control Index Name parallelPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.2 Description Defines the index (one-based) of the parallel port in this chassis. Syntax DellObjectRange Access Read-only Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3 Description Defines the capabilities of the parallel port.
book.book Page 406 Wednesday, March 6, 2013 12:37 AM Parallel Port Control Name Name parallelPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6 Description Defines the setup BIOS name of the parallel port. Syntax DellString Access Read-only Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port.
book.book Page 407 Wednesday, March 6, 2013 12:37 AM Serial Port Control Table Entry Name serialPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1 Description Defines the Serial Port Control Table entry. Syntax SerialPortControlTableEntry Access Not accessible Index serialPortControlchassisIndex, serialPortControlIndex Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.
book.book Page 408 Wednesday, March 6, 2013 12:37 AM Serial Port Control Settings Unique Name serialPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.4 Description Defines the settings of the serial port. Syntax DellSerialPortControlSettingsUnique (See Table 16-16) Access Read-only Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port.
book.book Page 409 Wednesday, March 6, 2013 12:37 AM USB Control Table Entry Name usbControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1 Description Defines the USB Table entry. Syntax UsbControlTableEntry Access Not accessible Index usbControlchassisIndex, usbControlIndex USB Control Chassis Index Name usbControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1 Description Defines index (one-based) of this chassis.
book.book Page 410 Wednesday, March 6, 2013 12:37 AM USB Control Settings Name usbControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4 Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only USB Control Name Name usbControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.
book.book Page 411 Wednesday, March 6, 2013 12:37 AM IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex, ideControlIndex IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 412 Wednesday, March 6, 2013 12:37 AM IDE Control Settings Unique Name ideControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.4 Description Defines the settings for the IDE controller. Syntax DellideControlCapabilitiesUnique (See Table 16-17) Access Read-only IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller.
book.book Page 413 Wednesday, March 6, 2013 12:37 AM Diskette Control Table Entry Name disketteControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1 Description Defines the Diskette Control Table entry. Syntax DellStatus Access Not accessible Index disketteControlchassisIndex, disketteControlIndex Diskette Control Chassis Index Name disketteControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 414 Wednesday, March 6, 2013 12:37 AM Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.4 Description Defines the control settings for the diskette controller. Syntax DellDisketteControlSettingsUnique Access Read-only Diskette Control Status Name disketteControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5 Description Defines the status of the diskette controller.
book.book Page 415 Wednesday, March 6, 2013 12:37 AM Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry. Syntax NetworkInterfaceControlTableEntry Access Not accessible Index networkInterfaceControlchassisIndex, networkInterfaceControlIndex Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.
book.book Page 416 Wednesday, March 6, 2013 12:37 AM Network Interface Control Capabilities Unique Name networkInterfaceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.3 Description Defines the capabilities of the NIC. Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Table 16-19) Access Read-only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.
book.book Page 417 Wednesday, March 6, 2013 12:37 AM BIOS Setting Table These MIB objects enable you to track the BIOS settings for your system. NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems. Name biosSettingTable Object ID 1.3.6.1.4.1.674.10892.1.1400.90 Description Defines the BIOS Setting Table. Syntax SEQUENCE OF BiosSettingTableEntry Access Not accessible BIOS Setting Table Entry Name biosSettingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.90.
book.book Page 418 Wednesday, March 6, 2013 12:37 AM Description Defines the index (one based) of the BIOS setting. Syntax DellObjectRange Access Read-only BIOS Setting Name Name biosSettingName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.3 Description Defines the name of the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting Display Name Name biosSettingDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.4 Description Defines the display name of the BIOS setting.
book.book Page 419 Wednesday, March 6, 2013 12:37 AM Syntax DisplayString Access Read-only BIOS Setting Pending Value Name biosSettingPendingValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.7 Description Defines the pending value of the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting Default Value Name biosSettingDefaultValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.8 Description Defines the default value of the BIOS setting.
book.book Page 420 Wednesday, March 6, 2013 12:37 AM Syntax DellUnsigned32BitRange Access Read-only BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the display name of the BIOS setting group for the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting FQDD Name biosSettingFQDD Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.
book.book Page 421 Wednesday, March 6, 2013 12:37 AM Table 16-1. Speaker Control Capabilities Unique (continued) Variable Name: DellSpeakerControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value highCapable(16) Setup BIOS can set the speaker volume to high. allVolumeCapable(30) Setup BIOS can set the speaker volume to any of the three settings. Table 16-2.
book.book Page 422 Wednesday, March 6, 2013 12:37 AM Table 16-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique (continued) Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bothCapable(14) Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIF. Table 16-4.
book.book Page 423 Wednesday, March 6, 2013 12:37 AM Table 16-5. Boot Sequence Control Capabilities Unique (continued) Variable Name: DellBootSequenceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bootFromDeviceListCapable(8) Setup BIOS can boot from a device list. bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first. allFirstCapable(30) Table 16-6. Setup BIOS can boot by any of the preceding methods first.
book.book Page 424 Wednesday, March 6, 2013 12:37 AM Table 16-7. BIOS Password Control Capabilities (continued) Variable Name: DellBIOSPasswordControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value passwordControlJumperDisable Capable(4) Setup BIOS is capable of determining if password control can be jumper disabled.
book.book Page 425 Wednesday, March 6, 2013 12:37 AM Table 16-9. BIOS Password Control Settings (continued) Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 16-10.
book.book Page 426 Wednesday, March 6, 2013 12:37 AM Table 16-12. Parallel Port Control Capabilities Variable Name: DellParallelPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS parallel port capabilities are unknown. enableCapable(2) Setup BIOS can enable the parallel port. lpt1Capable(4) Setup BIOS can support parallel port 1. lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1.
book.book Page 427 Wednesday, March 6, 2013 12:37 AM Table 16-14. Parallel Port Control Mode Settings Variable Name: DellParallelPortControlModeSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port mode is unknown. atModeEnabled(2) Setup BIOS has set the parallel port to AT mode. ps2ModeEnabled(4) Setup BIOS has set the parallel port to Personal Systems/2 (PS/2) mode.
book.book Page 428 Wednesday, March 6, 2013 12:37 AM Table 16-15. Serial Port Control Capabilities (continued) Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(86) COM1 and COM3 serial ports. com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(106) COM2 and COM4 serial ports.
book.book Page 429 Wednesday, March 6, 2013 12:37 AM Table 16-17. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown. ideControlAutoConfigOrEnable IDE controller is autoconfigurable or Capable(2) enable capable. Table 16-18.
book.book Page 430 Wednesday, March 6, 2013 12:37 AM Table 16-20. Network Interface Control Settings Variable Name: DellNetworkInterfaceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Network interface state is unknown. enabled(2) Network interface is enabled. enabledWithoutPXE(4) Network interface is enabled without PXE. Table 16-21.
book.book Page 431 Wednesday, March 6, 2013 12:37 AM Local Response Agent Group 17 The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis.
book.book Page 432 Wednesday, March 6, 2013 12:37 AM LRA Global Settings Table Name lRAGlobalSettingsTable Object ID 1.3.6.1.4.1.674.10892.1.1500.10 Description Defines the LRA Global Settings Table. Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1 Description Defines the LRA Global Settings Table entry.
book.book Page 433 Wednesday, March 6, 2013 12:37 AM LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings are disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.
book.book Page 434 Wednesday, March 6, 2013 12:37 AM LRA Action Table The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which of the system’s capabilities (global actions) are to be enabled. Name lRAActionTableTable Object ID 1.3.6.1.4.1.674.10892.1.1500.20 Description Defines the LRA Action Table.
book.book Page 435 Wednesday, March 6, 2013 12:37 AM LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
book.book Page 436 Wednesday, March 6, 2013 12:37 AM LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3 Description When the execute application value is set, provides the following user-assignable LRA information: • Name of the user application executable path • File name to execute Syntax DisplayString (SIZE (0..256) Access Read-write LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.
book.book Page 437 Wednesday, March 6, 2013 12:37 AM Table 17-1. LRA Capabilities Definitions (continued) Variable Name: DellLocalResponseAgentCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value rebootCapable(16) The LRA can reboot the system. powerCycleCapable(32) The LRA is capable of a system power cycle. powerOFFCapable(64) The LRA can shut the system power off. executeApplicationCapable(256) The LRA can execute a user mode application.
book.book Page 438 Wednesday, March 6, 2013 12:37 AM Table 17-2. LRA Thermal Shutdown Capabilities Unique (continued) Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected. The LRA enables activation of chassisdetermined action(s) when either a failure or a warning condition is detected.
book.book Page 439 Wednesday, March 6, 2013 12:37 AM Cost of Ownership Group 18 The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
book.book Page 440 Wednesday, March 6, 2013 12:37 AM Cost of Ownership Table Entry Name cooTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1 Description Defines the Cost of Ownership Table entry. Syntax CooTableEntry Access Not accessible Index coochassisIndex COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only COO State Name cooState Object ID 1.3.
book.book Page 441 Wednesday, March 6, 2013 12:37 AM COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-write COO Acquisition Install Date Name Name cooAquisitionInstallDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5 Description Defines the installation date and time for the system.
book.book Page 442 Wednesday, March 6, 2013 12:37 AM COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system. Syntax DellCostofOwnershipString Access Read-write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 443 Wednesday, March 6, 2013 12:37 AM COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system. Syntax DellCostofOwnershipString Access Read-write COO Extended Warranty Start Date Name Name cooExtendedWarrantyStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.13 Description Defines the extended warranty start date for this system.
book.book Page 444 Wednesday, March 6, 2013 12:37 AM COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system.
book.book Page 445 Wednesday, March 6, 2013 12:37 AM COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system.
book.book Page 446 Wednesday, March 6, 2013 12:37 AM COO Outsourcing Service Fee Name Name cooOutsourcingServiceFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.24 Description Defines amount that the outsourcing vendor charges for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Signing Authority Name Name cooOutsourcingSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 447 Wednesday, March 6, 2013 12:37 AM COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.28 Description Defines the name of the company that insures this system. Syntax DellCostofOwnershipString Access Read-write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.29 Description Defines the name of the asset tag.
book.book Page 448 Wednesday, March 6, 2013 12:37 AM COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system. Syntax DellCostofOwnershipString Access Read-write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 449 Wednesday, March 6, 2013 12:37 AM COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
book.book Page 450 Wednesday, March 6, 2013 12:37 AM COO Service Contract Table The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system. Name cooServiceContractTable Object ID 1.3.6.1.4.1.674.10892.1.1600.20 Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.
book.book Page 451 Wednesday, March 6, 2013 12:37 AM COO Service Contract State Name cooServiceContractState Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3 Description Defines the status of the service contract for this system. Syntax DellStateSettings Access Read-only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed.
book.book Page 452 Wednesday, March 6, 2013 12:37 AM COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system. Name cooCostEventLogTable Object ID 1.3.6.1.4.1.674.10892.1.1600.30 Description Defines the COO Cost Event Log Table. Syntax SEQUENCE OF COO CostEventLogTableEntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1.3.6.1.4.1.
book.book Page 453 Wednesday, March 6, 2013 12:37 AM COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4 Description Defines the duration of the event for this system.
book.book Page 454 Wednesday, March 6, 2013 12:37 AM COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system. Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.
book.book Page 455 Wednesday, March 6, 2013 12:37 AM COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3 Description Defines the state of the warranty for this system. Syntax DellStateSettings Access Read-only COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty.
book.book Page 456 Wednesday, March 6, 2013 12:37 AM COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system. Name cooLeaseInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
book.book Page 457 Wednesday, March 6, 2013 12:37 AM COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only COO Lease Information State Name cooLeaseInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3 Description Defines the lease information state for this system.
book.book Page 458 Wednesday, March 6, 2013 12:37 AM COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
book.book Page 459 Wednesday, March 6, 2013 12:37 AM COO Schedule Number Table Name cooScheduleNumberTable Object ID 1.3.6.1.4.1.674.10892.1.1600.60 Description Defines the COO Schedule Number Information Table. Syntax SEQUENCE OF CooScheduleNumberTableEntry Access Not accessible COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry.
book.book Page 460 Wednesday, March 6, 2013 12:37 AM COO Schedule Number State Name cooScheduleNumberState Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.3 Description Defines the schedule number information state of this system. Syntax DellStateSettings Access Read-only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.
book.book Page 461 Wednesday, March 6, 2013 12:37 AM COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry. Syntax CooOptionsTableEntry Access Not accessible Index cooOptionschassisIndex, cooOptionsIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 462 Wednesday, March 6, 2013 12:37 AM COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system. Syntax DellUnsigned32BitRange Access Read-write COO Options Description Name Name cooOptionsDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.5 Description Defines the option information description name.
book.book Page 463 Wednesday, March 6, 2013 12:37 AM COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information.
book.book Page 464 Wednesday, March 6, 2013 12:37 AM COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name.
book.book Page 465 Wednesday, March 6, 2013 12:37 AM COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex, cooRepairIndex COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 466 Wednesday, March 6, 2013 12:37 AM COO Repair Counter Name cooRepairCounter Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4 Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system.
book.book Page 467 Wednesday, March 6, 2013 12:37 AM COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information.
book.book Page 468 Wednesday, March 6, 2013 12:37 AM COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5 Description Defines the type of component, system, or network problem that occurred. Syntax DellUnsigned32BitRange Access Read-write COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided.
book.book Page 469 Wednesday, March 6, 2013 12:37 AM COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1 Description Defines the COO Trouble Ticket Table entry. Syntax cooTroubleTicketTableEntry Access Not accessible Index cooTroubleTicketchassisIndex, cooTroubleTicketIndex COO Trouble Ticket Chassis Index Name cooTroubleTicketchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
book.book Page 470 Wednesday, March 6, 2013 12:37 AM COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4 Description Defines the support information index that references the trouble ticket. Syntax DellUnsigned32BitRange Access Read-write COO Trouble Ticket Number Name Name cooTroubleTicketNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
book.book Page 471 Wednesday, March 6, 2013 12:37 AM Table 18-2. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 18-3.
book.
book.book Page 473 Wednesday, March 6, 2013 12:37 AM Remote Access Group 19 The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations.
book.book Page 474 Wednesday, March 6, 2013 12:37 AM Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware.
book.book Page 475 Wednesday, March 6, 2013 12:37 AM Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware.
book.book Page 476 Wednesday, March 6, 2013 12:37 AM Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 477 Wednesday, March 6, 2013 12:37 AM Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 478 Wednesday, March 6, 2013 12:37 AM Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 479 Wednesday, March 6, 2013 12:37 AM Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1.3.
book.book Page 480 Wednesday, March 6, 2013 12:37 AM Remote Access Table The following MIB object sets up the Remote Access Table. Name remoteAccessTable Object ID 1.3.6.1.4.1.674.10892.1.1700.10 Description Defines the Remote Access Table. Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1 Description Defines the Remote Access Table entry.
book.book Page 481 Wednesday, March 6, 2013 12:37 AM Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (See Table 19-1) Access Read-only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4 Description Defines the state capabilities of the remote access hardware.
book.book Page 482 Wednesday, March 6, 2013 12:37 AM Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 483 Wednesday, March 6, 2013 12:37 AM Remote Access Control Settings Name remoteAccessControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.11 Description Defines the control settings of the remote access hardware. Syntax DellRemoteAccessControlSettings (See Table 19-3) Access Read-write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 484 Wednesday, March 6, 2013 12:37 AM Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15 Description Defines the LAN settings of the remote access hardware. Syntax DellRemoteAccessLANSettings (See Table 19-7) Access Read-write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.16 Description Defines the host capabilities of the remote access hardware.
book.book Page 485 Wednesday, March 6, 2013 12:37 AM Remote Access Out-of-Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19 Description Defines the out-of-band SNMP settings of the remote access hardware. Syntax DellRemoteAccessOutOfBandSNMPSettings (See Table 19-11) Access Read-write Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address Name remoteAccessSMTPServerIPAddress Object ID 1.3.6.1.4.1.674.
book.book Page 486 Wednesday, March 6, 2013 12:37 AM Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.23 Description Defines the IP address of the update server providing the firmware image used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 487 Wednesday, March 6, 2013 12:37 AM Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware.
book.book Page 488 Wednesday, March 6, 2013 12:37 AM Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 489 Wednesday, March 6, 2013 12:37 AM Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote User Administration Table Name remoteUserAdminTable Object ID 1.3.6.1.4.1.
book.book Page 490 Wednesday, March 6, 2013 12:37 AM Remote User Admin Chassis Index Name remoteUserAdminChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Admin Adapter Index Name remoteUserAdminAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 491 Wednesday, March 6, 2013 12:37 AM Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.5 Description Defines the state settings for this remote access user. Syntax DellRemoteUserAdminStateSettings (See Table 19-13) Access Read-write Remote User Admin Status Name remoteUserAdminStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.6 Description Defines the status for this remote access user.
book.book Page 492 Wednesday, March 6, 2013 12:37 AM Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.9 Description Defines the privileges for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 493 Wednesday, March 6, 2013 12:37 AM Remote User Admin Alert Filter DRS Capabilities Name remoteUserAdminAlertFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.13 Description Defines the DRS events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Remote User Admin Alert Filter System Capabilities Name remoteUserAdminAlertFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 494 Wednesday, March 6, 2013 12:37 AM Remote User Admin Pager Numeric Hang-up Delay Name remoteUserAdminPagerNumericHangupDelay Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.17 Description Defines the numeric pager hang-up delay for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Pager Alpha Phone Number Name Name remoteUserAdminPagerAlphaPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 495 Wednesday, March 6, 2013 12:37 AM Remote User Admin Pager Alpha Custom Message Name Name remoteUserAdminPagerAlphaCustomMessageName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Alpha Modem Connect Time-out Name remoteUserAdminPagerAlphaModemConnectTimeout Object ID 1.3.6.
book.book Page 496 Wednesday, March 6, 2013 12:37 AM Remote User Admin Pager Modem Init String Name Name remoteUserAdminPagerModemInitStringName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.25 Description Defines the initialization string to be sent to the pager modem for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Modem Port Name remoteUserAdminPagerModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 497 Wednesday, March 6, 2013 12:37 AM Remote User Admin Control Capabilities Name remoteUserAdminControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.29 Description Defines the control capabilities for this remote access user. Syntax DellRemoteUserAdminControlCapabilities (See Table 19-14 on page 519) Access Read-only Remote User Admin Control Settings Name remoteUserAdminControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 498 Wednesday, March 6, 2013 12:37 AM Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1 Description Defines the Remote Access SNMP Trap Destination Table entry. Syntax RemoteSNMPTrapTableEntry Access Not accessible Index remoteSNMPTrapChassisIndex, remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 499 Wednesday, March 6, 2013 12:37 AM Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.3 Description Defines the index (one-based) of this remote access SNMP trap destination. Syntax DellObjectRange Access Read-only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.4 Description Defines the state capabilities of this remote access SNMP trap destination.
book.book Page 500 Wednesday, March 6, 2013 12:37 AM Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.7 Description Defines the IP address of this remote access SNMP trap destination. Syntax IpAddress Access Read-write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 501 Wednesday, March 6, 2013 12:37 AM Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 502 Wednesday, March 6, 2013 12:37 AM Remote Dial-Up Table Name remoteDialUpTable Object ID 1.3.6.1.4.1.674.10892.1.1700.40 Description Defines the Remote Access Dial-Up Table. Syntax SEQUENCE OF RemoteDialUpTableEntry Access Not accessible Remote Dial-Up Table Entry Name remoteDialUpTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1 Description Defines the Remote Access Dial-Up Table entry.
book.book Page 503 Wednesday, March 6, 2013 12:37 AM Remote Dial-Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-up functionality. Syntax DellObjectRange Access Read-only Remote Dial-Up Index Name remoteDialUpIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
book.book Page 504 Wednesday, March 6, 2013 12:37 AM Remote Dial-Up Status Name remoteDialUpStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.6 Description Defines the status of this remote access dial-up functionality. Syntax DellStatus Access Read-only Remote Dial-Up PPP Dial-In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.7 Description Defines the base IP address of the PPP server for this remote access dial-up functionality.
book.book Page 505 Wednesday, March 6, 2013 12:37 AM Remote Dial-Up Dial-Out Modem Connect Time-out Name remoteDialUpDialOutModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.10 Description Defines the modem dial-out time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
book.book Page 506 Wednesday, March 6, 2013 12:37 AM Remote Dial-Up Modem Port Name remoteDialUpModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.14 Description Defines the port for the modem used by this remote access dialup functionality. Syntax DellUnsigned32BitRange Access Read-write Remote User Dial-In Configuration Table Name remoteUserDialInCfgTable Object ID 1.3.6.1.4.1.674.10892.1.1700.50 Description Defines the Remote Access User Dial-In Configuration Table.
book.book Page 507 Wednesday, March 6, 2013 12:37 AM Remote User Dial-In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration Adapter Index Name remoteUserDialInCfgAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
book.book Page 508 Wednesday, March 6, 2013 12:37 AM Remote User Dial-In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.5 Description Defines the state settings of this remote access dial-in user. Syntax DellRemoteUserDialInStateSettings (See Table 19-26) Access Read-write Remote User Dial-In Configuration Status Name remoteUserDialInCfgStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
book.book Page 509 Wednesday, March 6, 2013 12:37 AM Remote User Dial-In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9 Description Defines the callback phone number for this remote access dial-in user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out Table Name remoteDialOutTable Object ID 1.3.6.1.4.1.674.10892.1.1700.60 Description Defines the Remote Access Dial-Out Table.
book.book Page 510 Wednesday, March 6, 2013 12:37 AM Remote Dial-Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Remote Dial-Out Dial-Out Index Name remoteDialOutDialOutIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.
book.book Page 511 Wednesday, March 6, 2013 12:37 AM Remote Dial-Out Status Name remoteDialOutStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.6 Description Defines the status of this remote access dial-out functionality. Syntax DellStatus Access Read-only Remote Dial-Out IP Address Name remoteDialOutIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7 Description Defines the IP address for this remote access dial-out destination.
book.book Page 512 Wednesday, March 6, 2013 12:37 AM Remote Dial-Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.10 Description Defines the PPP password for this remote access dial-out destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 19-1.
book.book Page 513 Wednesday, March 6, 2013 12:37 AM Table 19-2. Remote Access Control Capabilities (continued) Variable Name: DellRemoteAccessControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value logResetCapable(2) The remote access hardware can reset its integrated logs. hardResetCapable(4) The remote access hardware can perform a hard reset. softResetCapable(8) The remote access hardware can perform a soft reset.
book.book Page 514 Wednesday, March 6, 2013 12:37 AM Table 19-3. Remote Access Control Settings (continued) Variable Name: DellRemoteAccessControlSettings Data Type: Integer Possible Data Values Meaning of Data Value defaultConfigReset(32) The remote access hardware resets to its default settings. shutdown(64) The remote access hardware shuts down. Table 19-4.
book.book Page 515 Wednesday, March 6, 2013 12:37 AM Table 19-5. Remote Access Monitor Settings Variable Name: DellRemoteAccessMonitorSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor settings. unknown(1) The remote access hardware monitor settings are unknown. extPwrSupplyMonitorIfConn The remote access hardware monitors the ectedEnabled(2) external power supply, if connected.
book.book Page 516 Wednesday, March 6, 2013 12:37 AM Table 19-7. Remote Access LAN Settings Variable Name: DellRemoteAccessLANSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no LAN settings. unknown(1) The remote access hardware LAN settings are unknown. nicEnabled(2) The remote access hardware NIC is enabled. nicDHCPEnabled(4) The remote access hardware NIC uses DHCP to obtain an IP address. Table 19-8.
book.book Page 517 Wednesday, March 6, 2013 12:37 AM Table 19-9. Remote Access Host Settings Variable Name: DellRemoteAccessHostSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host settings. unknown(1) The remote access hardware host settings are unknown. smtpEmailEnabled(2) The remote access hardware SMTP client is enabled for sending e-mail.
book.book Page 518 Wednesday, March 6, 2013 12:37 AM Table 19-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Settings Variable Name: DellRemoteAccessOutOfBandSNMPSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP settings. unknown(1) The remote access hardware out-of-band SNMP settings are unknown. oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP agent is enabled.
book.book Page 519 Wednesday, March 6, 2013 12:37 AM Table 19-13. Remote User Admin State Settings Variable Name: DellRemoteUserAdminStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the not ready state. numericPagerEnabled(8) Numeric paging is enabled for the admin user.
book.book Page 520 Wednesday, March 6, 2013 12:37 AM Table 19-15. Remote User Admin Control Settings Variable Name: DellRemoteUserAdminControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no control settings. unknown(1) The admin user control settings are unknown. numericPagerTest(2) A numeric pager test is performed for the admin user. alphaPagerTest(4) An alphanumeric pager test is performed for the admin user.
book.book Page 521 Wednesday, March 6, 2013 12:37 AM Table 19-17. Remote User Admin Alpha Baud Type Variable Name: DellRemoteUserAdminAlphaBaudType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The remote user alphanumeric baud rate is not one of the following: unknown(2) The remote user alphanumeric baud rate is unknown. alphaBaud300(3) The remote user alphanumeric baud rate is 300. alphaBaud1200(4) The remote user alphanumeric baud rate is 1200. Table 19-18.
book.book Page 522 Wednesday, March 6, 2013 12:37 AM Table 19-20. Remote SNMP Trap Control Capabilities Variable Name: DellRemoteSNMPTrapControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control capabilities. unknownCapabilities The SNMP trap destination control capabilities are (1) unknown. trapTestCapable(2) A SNMP trap test can be performed for the SNMP trap destination. Table 19-21.
book.book Page 523 Wednesday, March 6, 2013 12:37 AM Table 19-22. Remote Dial-Up State Capabilities (continued) Variable Name: DellRemoteDialUpStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value notReadyCapable(4) The dial-up functionality can be in the not ready state. dialInCapable(8) The dial-up functionality can support the dial-in feature. dialOutCapable(16) The dial-up functionality can support the dial-out feature.
book.book Page 524 Wednesday, March 6, 2013 12:37 AM Table 19-23. Remote Dial-Up State Settings (continued) Variable Name: DellRemoteDialUpStateSettings Data Type: Integer Possible Data Values Meaning of Data Value dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyEnabled The dial-up functionality accepts any authentication (64) type (including clear text) for the dial-in feature.
book.book Page 525 Wednesday, March 6, 2013 12:37 AM Table 19-25. Remote User Dial-In State Capabilities Variable Name: DellRemoteUserDialInStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities. unknownCapabilities(1) The dial-in user state capabilities are unknown. enableCapable(2) The dial-in user can be disabled or enabled. notReadyCapable(4) The dial-in user can be in the not ready state.
book.book Page 526 Wednesday, March 6, 2013 12:37 AM Table 19-27. Remote Dial-Out State Capabilities Variable Name: DellRemoteDialOutStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state capabilities. unknownCapabilities(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable(4) The dial-out destination can be in the not ready state.
book.book Page 527 Wednesday, March 6, 2013 12:37 AM Table 19-28. Remote Dial-Out State Settings Variable Name: DellRemoteDialOutStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state settings. unknown(1) The dial-out destination state settings are unknown. enabled(2) The dial-out destination is disabled or enabled. notReady(4) The dial-out destination is in the not ready state.
book.
book.book Page 529 Wednesday, March 6, 2013 12:37 AM 20 Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using failover clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems.
book.book Page 530 Wednesday, March 6, 2013 12:37 AM Cluster Chassis Index Name clusterChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster.
book.book Page 531 Wednesday, March 6, 2013 12:37 AM Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
book.book Page 532 Wednesday, March 6, 2013 12:37 AM Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 20-1. Cluster Type Variable Name: DellClusterType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown. highAvailabilityCluster(2) The cluster type is a high-availability cluster.
book.book Page 533 Wednesday, March 6, 2013 12:37 AM 21 Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system.
book.book Page 534 Wednesday, March 6, 2013 12:37 AM BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex, bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 535 Wednesday, March 6, 2013 12:37 AM BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-write BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
book.book Page 536 Wednesday, March 6, 2013 12:37 AM BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC.
book.book Page 537 Wednesday, March 6, 2013 12:37 AM BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12 Description Defines the IPv4 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..1024)) Access Read-only BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.13 Description Defines the IPv6 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..
book.book Page 538 Wednesday, March 6, 2013 12:37 AM BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1 Description Defines the BMC Serial Interface Table Entry. Syntax BmcSerialInterfaceTableEntry Access Not accessible Index bmcSerialInterfaceChassisIndex, bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
book.book Page 539 Wednesday, March 6, 2013 12:37 AM BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4 Description Defines the state capabilities of the BMC serial interface. Syntax DellStateCapabilities Access Read-only BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.5 Description Defines the state settings of the BMC serial interface.
book.book Page 540 Wednesday, March 6, 2013 12:37 AM BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.8 Description Defines the connection mode capabilities of the BMC serial interface. Syntax DellBMCSerialConnectionModeCapabilities Access Read-only BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
book.book Page 541 Wednesday, March 6, 2013 12:37 AM Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table. Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.30.
book.book Page 542 Wednesday, March 6, 2013 12:37 AM BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface.
book.book Page 543 Wednesday, March 6, 2013 12:37 AM BMC LAN Interface Status Name bmcLANInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6 Description Defines the status of the BMC LAN interface. Syntax DellStatus Access Read-only BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7 Description Defines the BMC channel number of the BMC LAN interface.
book.book Page 544 Wednesday, March 6, 2013 12:37 AM BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.10 Description Defines the subnet mask of the BMC LAN interface. Syntax IpAddress Access Read-only BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11 Description Defines the IP address of the default gateway for the BMC LAN interface.
book.book Page 545 Wednesday, March 6, 2013 12:37 AM Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 21-1. BMC Serial Connection Mode Capabilities Variable Name: DellBMCSerialConnectionModeCapabilities Data Type: Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No mode capabilities.
book.book Page 546 Wednesday, March 6, 2013 12:37 AM Table 21-3. BMC Serial Flow Control Type Variable Name: DellBMCSerialFlowControlType Data Type: Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 21-4.
book.book Page 547 Wednesday, March 6, 2013 12:37 AM Table 21-6. BMC Management Controller Type Variable Name: DellManagementControllerType Data Type: Integer Possible Data Values Meaning of Data Value -- legacyBMC(0) Controller type is legacy Baseboard Management Controller. iDRAC(8) Controller type is iDRAC. iDRAC6(10) Controller type is Integrated Dell Remote Access Controller 6. iDRAC6Modular(11) Controller type is Integrated Dell Remote Access Controller 6 (Modular).
book.
book.book Page 549 Wednesday, March 6, 2013 12:37 AM 22 Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system.
book.book Page 550 Wednesday, March 6, 2013 12:37 AM FRU Chassis Index Name fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1 Description Defines the index (one-based) of the chassis containing the FRU. Syntax DellObjectRange Access Read-only FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.
book.book Page 551 Wednesday, March 6, 2013 12:37 AM FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturer Name Name fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6 Description Defines the manufacturer of the FRU. Syntax DisplayString (SIZE (0..
book.book Page 552 Wednesday, March 6, 2013 12:37 AM FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10 Description Defines the manufacturing date of the FRU. Syntax DellDateName Access Read-only FRU Asset Tag Name Name fruAssetTagName Object ID 1.3.
book.book Page 553 Wednesday, March 6, 2013 12:37 AM Field Replaceable Unit Group Variable Values This section includes definitions for server administrator-specific variable values. Table 22-1. FRU Information State Variable Name: DellFRUInformationState Data Type: Integer Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available.
book.
book.book Page 555 Wednesday, March 6, 2013 12:37 AM Storage Management Group 23 The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software.
book.book Page 556 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Global Status Name globalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.2 Description Identifies the global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group.
book.book Page 557 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name softwareDescription Description Identifies the product description for the Storage Management software. Syntax DisplayString Access Read-only Storage Management Information Group The Storage Management Information Group defines the properties that identify the Storage Management software SNMP agent. Display Name Name displayName Object ID 1.3.6.1.4.1.674.10893.1.20.100.
book.book Page 558 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion.
book.book Page 559 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name agentTimeStamp Description Identifies the last time the agent values have been updated. Universal time in seconds since UTC 1/1/70. Syntax Integer Access Read-only Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 560 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When Agent Modifier is set, the modifier is active. Bit definitions: Bit 3: agent in debug mode. All other bits are product specific. Syntax Integer Access Read-only Agent Refresh Rate Name agentRefreshRate Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 561 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management.
book.book Page 562 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 563 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description Identifies the previous global status of the system managed by the Storage Management software.
book.book Page 564 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects. • Controller Table—describes available properties for each controller on the managed system.
book.book Page 565 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm • Temperature Probe Table—describes available properties for each temperature probe on the managed system. • Temperature Probe Connection Table—describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table.
book.book Page 566 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Entry Name controllerEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1 Description Defines the controller table entry, which is an entry in the table of RAID controllers. Syntax ControllerEntry Access Not accessible Index controllerNumber Controller Number Name controllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 567 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's vendor's name. Syntax DisplayString Access Read-only Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 568 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerState Description Identifies the status of the controller's subsystem (which includes any devices connected to it).
book.book Page 569 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Controller Rebuild Rate in Percent Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 570 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Cache Size in Bytes Name controllerCacheSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.10 Description Identifies the controller's current amount of cache memory that is less than a megabyte. This combined with the controllerCacheSizeInMB is the total amount of memory.
book.book Page 571 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Host Port Count Name controllerHostPortCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.14 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 572 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerDriveChannelCount Syntax Integer Access Read-only Controller Fault Tolerant Name controllerFaultTolerant Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.18 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Port 0 World Wide Name Name controllerC0Port0WorldWideName Object ID 1.3.
book.book Page 573 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerC0Port0ID Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Target Name controllerC0Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 574 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller C0 Operating System Controller Name controllerC0OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.24 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Battery State Name controllerC0BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 575 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C1 Target Name controllerC1Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29 Description This entry is obsolete.
book.book Page 576 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Battery State C1 Name controllerC1BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Node World Wide Name Name controllerNodeWWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.33 Description This entry is obsolete.
book.book Page 577 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Roll-Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 578 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerComponentStatus Description Indicates the status of the controller itself without the propagation of any contained component status.
book.book Page 579 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Displays the durable unique ID for this controller. Syntax DisplayString Access Read-only Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates the state or setting for the controller's alarm.
book.book Page 580 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Cluster Mode Name controllerClusterMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.43 Description Identifies if the controller is in cluster mode. Possible values: 1: Enabled 2: Disabled 3: Active (enabled and active) 99: Not Applicable Syntax Integer Access Read-only Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 581 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerSCSIInitiatorID Syntax Integer Access Read-only Controller Channel Count Name controllerChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 Description Displays the number of channels on the controller. Syntax Integer Access Read-only Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 582 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.50 Description Displays the rate for background initialization on the controller. Syntax Integer Access Read-only Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 583 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerPatrolReadState Description Displays the state of the patrol read.
book.book Page 584 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Patrol Read Iterations Name controllerPatrolReadIterations Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.54 Description Displays the number of times Patrol Read has been run on this controller. Syntax Integer Access Read-only Controller Storport Driver Version Name controllerStorportDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 585 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.
book.book Page 586 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Encryption Key Present Name controllerEncryptionKeyPresent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 Description Indicates presence of encryption key for the controller. Possiable Values: 1 - Yes 0 - No 99 - Not Applicable Syntax Integer Access Read-only Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 587 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerSpinDownUnconfiguredDrives Access Read-only Controller Spin Down Hot Spare Drives Name controllerSpinDownHotSpareDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.61 Description Indicates controller capability to move hot spare drives to power save mode.
book.book Page 588 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Spin Down Time Interval Name controllerSpinDownTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62 Description Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode. Possiable Values: 30 to 1440 NOTE: A value of 9999 indicates that the feature is not available.
book.book Page 589 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Controller Spin Down Configured Drives Name controllerSpinDownConfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.65 Description Indicates the controller capability to spin down configured physical disks.
book.book Page 590 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name controllerConfiguredDrivesSpinUpTime Access Read-only Controller Configured Drives SpinUp TimeInterval Name controllerConfiguredDrivesSpinUpTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.68 Description Indicates the configured drives spin up time interval in hours.
book.book Page 591 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name channelTable Description Defines the channel table. Syntax SEQUENCE OF ChannelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry. Syntax ChannelEntry Access Not accessible Index: channelNumber Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.
book.book Page 592 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Channel State Name channelState Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3 Description Identifies the current state of the channel. Possible states: 0: Unknown 1: Ready - The I/O has resumed 2: Failed 3: Online 4: Offline - The I/O has paused 6: Degraded Syntax Integer Access Read-only Channel Severity Name channelSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
book.book Page 593 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name channelTermination Syntax Integer Access Read-only Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.6 Description Identifies the SCSI ID of the controller to which the channel belongs.
book.book Page 594 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Channel Roll-Up Status Name channelRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7 Description Identifies the severity of the channel state. This is the combined status of the channel and its components.
book.book Page 595 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name channelNexusID Syntax DisplayString Access Read-only Channel Data Rate Name channelDataRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.10 Description Identifies the data rate of the channel. Syntax DisplayString Access Read-only Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11 Description Identifies the bus type of the channel.
book.book Page 596 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table.
book.book Page 597 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1 Description Defines the enclosure table entry. Syntax EnclosureEntry Access Not accessible Index enclosureNumber Enclosure Number Name enclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.1 Description Identifies the instance number of the enclosure entry.
book.book Page 598 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.4 Description Identifies the current condition of the enclosure (which includes any devices connected to it.) Possible values: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 599 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureProcessorVersion Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure Service Tag Name enclosureServiceTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.8 Description Displays the enclosure identification used when consulting customer support.
book.book Page 600 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureSplitBusPartNumber Syntax DisplayString Access Read-only Enclosure Product ID Name enclosureProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12 Description Displays the enclosure's product identification. This also corresponds to the enclosure type. Syntax DisplayString Access Read-only Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.
book.book Page 601 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureESM2PartNumber Description This entry is obsolete for Storage Management.
book.book Page 602 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure.
book.book Page 603 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Configuration Name enclosureConfig Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.18 Description Identifies the current configuration of the enclosure's backplane. Possible values: 1: Joined 2: Split Bus 3: Clustered 4: Unified Syntax Integer Access Read-only Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
book.book Page 604 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane. Syntax Integer Access Read-only Enclosure SCSI ID Name enclosureSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
book.book Page 605 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureComponentStatus Description Identifies the status of the enclosure itself without the propagation of any contained component status.
book.book Page 606 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.25 Description Identifies the durable unique ID for the enclosure. Syntax Integer Access Read-only Enclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.26 Description Displays the firmware version of the enclosure.
book.book Page 607 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureSerialNumber Description Displays the serial number of the enclosure. Syntax DisplayString Access Read-only Enclosure SAS Address Name enclosureSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.30 Description Displays the specified SAS address if the enclosure is a SAS enclosure.
book.book Page 608 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Occupied Slot Count Name enclosureOccupiedSlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.31 Description Displays the number of physical disk slots occupied in a storage enclosure. NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Enclosure Total Slots Name enclosureTotalSlots Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 609 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Table This section describes available properties for each physical array disk on the managed system. The following object sets up the Array Disk Table. Name arrayDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4 Description Defines the array disk table. Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.
book.book Page 610 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description Displays the array disk's manufacturer's name.
book.book Page 611 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name arrayDiskState Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller.
book.book Page 612 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.
book.book Page 613 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Array Disk Product ID Name arrayDiskProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 614 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which the array disk belongs. Syntax DisplayString Access Read-only Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 615 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in (megabytes) of the largest contiguous free space on the array disk. If this size is 0, the free space on the array dissk is less than a megabyte.
book.book Page 616 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.17 Description Identifies the amount (in megabytes) of used space on the array disk. If this size is 0, used space on the array disk is smaller than a megabyte. Syntax Integer Access Read-only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.
book.book Page 617 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name arrayDiskFreeSpaceInBytes Description Identifies the size (in bytes) of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk. Syntax Integer Access Read-only Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 618 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare.
book.book Page 619 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Component Status Name arrayDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.24 Description Identifies the status of the array disk itself without the propagation of any contained component status.
book.book Page 620 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for the array disk. Syntax DisplayString Access Read-only Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for the array disk.
book.book Page 621 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name arrayDiskNegotiatedSpeed Description Indicates the speed at which the drive is actually running in MPS (megabytes per second).
book.book Page 622 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). Syntax Integer Access Read-only Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 623 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.
book.book Page 624 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which the disk was manufactured. Syntax DisplayString Access Read-only Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description Indicates the Media type of the array disk.
book.book Page 625 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Alta Vendor Id Name arrayDiskAltaVendorId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.37 Description Provides the vendor information for Alta interposer. Syntax Octet String Access Read-only Array Disk Alta Product Id Name arrayDiskAltaProductId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38 Description Provides the product ID for Alta interposer.
book.book Page 626 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name arrayDiskEncryptionCapable Access Read-only Array Disk Encrypted Name arrayDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.41 Description Indicates if the physical disk is encryption enabled. Possible Values: 1 - Yes 0 - No 99 - Not Applicable Syntax Integer Access Read-only Array Disk Power State Name arrayDiskPowerState Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 627 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name arrayDiskDriveWriteCache Description Indicates the drive write cache capability for PCIe SSD devices. Possible Values: 1 - Enabled 0 - Disabled 99 - Undetermined/NotApplicable Syntax Integer Access Read-only Array Disk Model Number Name arrayDiskModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.44 Description Provides the PCIe SSD device model number.
book.book Page 628 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Device Life Status Name arrayDiskDeviceLifeStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.47 Description Provides the PCIe SSD device life status.
book.book Page 629 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Enclosure Connection Entry Name arrayDiskEnclosureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1 Description Defines the array disk enclosure connection table entry.
book.book Page 630 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs.
book.book Page 631 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs.
book.book Page 632 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.
book.book Page 633 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in the connection. Syntax Integer Access Read-only Array Disk Channel Connection Channel Name Name arrayDiskChannelConnectionChannelName Object ID 1.3.6.1.4.
book.book Page 634 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Channel Connection Controller Number Name arrayDiskChannelConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.7 Description Identifies the instance number in the controllerTable of the controller to which the array disk is connected. Syntax Integer Access Read-only Fan Table This section describes available properties for each fan on the managed system.
book.book Page 635 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fan Number Name fanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1 Description Identifies the instance number of the fan entry. Syntax Integer Access Read-only Fan Name Name Fan Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 Description Identifies the fan's name as represented in Storage Management.
book.book Page 636 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name fanState Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management.
book.book Page 637 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name fanProbeMinimumWarning Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete.
book.book Page 638 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fan Probe Current Value Name fanProbeCurrValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 Description Identifies the current speed of the fan. Syntax DisplayString Access Read-only Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure.
book.book Page 639 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Fan Component Status Name fanComponentStatus Object ID 1.3.6.1.4.1.674.
book.book Page 640 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for the fan. Syntax DisplayString Access Read-only Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure.
book.book Page 641 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name fanConnectionEntry Syntax FanConnectionEntry Access Not accessible Index fanConnectionNumber Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry. Syntax Integer Access Read-only Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.
book.book Page 642 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which the fan belongs. Syntax DisplayString Access Read-only Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.
book.book Page 643 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Power Supply Entry Name powerSupplyEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1 Description Defines the power supply table entry. Syntax PowerSupplyEntry Access Not accessible Index powerSupplyNumber Power Supply Number Name powerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 Description Identifies the instance number of the power supply entry.
book.book Page 644 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Power Supply State Name powerSupplyState Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.4 Description Identifies the current state of the power supply. Possible states: 0: Unknown 1: Ready 2: Failed 5: Not Installed 6: Degraded 11: Removed Syntax Integer Access Read-only Power Supply Severity Name powerSupplySeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.
book.book Page 645 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 Description This entry is obsolete. This setting is not supported by power supplies managed under Storage Management Syntax DisplayString Access Read-only Power Supply Roll-Up Status Name powerSupplyRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.
book.book Page 646 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Power Supply Component Status Name powerSupplyComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 Description Severity of the power supply state. This is the combined status of the power supply and its components.
book.book Page 647 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Power Supply Connection Table This section describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Power Supply Connection Table. Name powerSupplyConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.
book.book Page 648 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 Description Identifies the name of the power supply in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.
book.book Page 649 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Power Supply Connection Firmware Version Name powerSupplyConnectionFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.6 Description Displays power supply connection firmware version. NOTE: Available above 1.04 firmware version.
book.book Page 650 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name temperatureProbeEntry Access Not accessible Index TemperatureProbeNumber Temperature Probe Number Name temperatureProbeNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.1 Description Identifies the instance number of the temperature probe entry. Syntax Integer Access Read-only Temperature Probe Name Name temperatureProbeName Object ID 1.3.6.1.4.1.674.10893.1.20.130.
book.book Page 651 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name temperatureProbeState Description Identifies the current state of the temperature probe.
book.book Page 652 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Temperature Probe Minimum Warning Name temperatureProbeMinWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.7 Description Identifies the minimum temperature that forces the probe into a warning state. Syntax Integer Access Read-only Temperature Probe Minimum Critical Name temperatureProbeMinCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
book.book Page 653 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name temperatureProbeMaxCritical Access Read-only Temperature Probe Current Value Name temperatureProbeCurValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.11 Description Identifies the current temperature of the probe. Syntax Integer Access Read-only Temperature Probe Roll-Up Status Name temperatureProbeRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
book.book Page 654 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name temperatureProbeComponentStatus Description Identifies the status of the temperature probe itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.
book.book Page 655 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1 Description Defines the temperature probe connection table entry. Syntax TemperatureConnectionEntry Access Not accessible Index temperatureConnectionNumber Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.
book.book Page 656 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name temperatureConnectionTemperatureNumber Access Read-only Temperature Probe Connection Enclosure Name Name temperatureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which the temperature probe belongs.
book.book Page 657 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Management Module Entry Name EnclosureManagementModuleEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1 Description Defines the enclosure management module table entry. Syntax EnclosureManagementModuleEntry Access Not accessible Index enclosureManagementModuleNumber Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.
book.book Page 658 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureManagementModuleVendor Access Read-only Enclosure Management Module State Name enclosureManagementModuleState Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 Description Identifies the current state of the enclosure management module.
book.book Page 659 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name enclosureManagementModulePartNumber Description Identifies the part number of the enclosure memory module. Syntax Display String Access Read-only Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of enclosure management module.
book.book Page 660 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Identifies the severity of the enclosure management module state. This is the combined status of the EMM and its components.
book.book Page 661 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 Description Displays the durable unique ID for this EMM. Syntax DisplayString Access Read-only Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
book.book Page 662 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry.
book.book Page 663 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 Description Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in the connection.
book.book Page 664 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Battery Table This section describes available properties for each controller battery on the managed system. The following object sets up the Battery Table. Name batteryTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.15 Description Defines the battery table. Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 665 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Battery Name Name batteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.2 Description Identifies the battery's name as represented in Storage Management. Syntax DisplayString Access Read-only Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name.
book.book Page 666 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Battery Roll-Up Status Name batteryRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 Description Identifies the severity of the battery state. This is the combined status of the battery and its components.
book.book Page 667 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Battery Charge Count Name batteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.7 Description Identifies the number of charges that have been applied to the battery. Syntax Integer Access Read-only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
book.book Page 668 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name batteryPredictedCapacity Description Displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete.
book.book Page 669 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name batteryLearnState Syntax Integer Access Read-only Battery ID Name batteryID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.13 Description Represents the unique id for the battery. Syntax Integer Access Read-only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
book.book Page 670 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name batteryLearnMode Access Read-only Battery Connection Table This section describes the connection between each controller battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the controller Table. The following object sets up the Battery Connection Table. Name batteryConnectionTable Object ID 1.3.6.1.4.1.
book.book Page 671 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
book.book Page 672 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other. This group and all of its associated tables and objects are not supported on Microsoft Windows Advanced Server Limited Edition 64-bit operating system (Windows.
book.book Page 673 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskEntry Description Defines the virtual disk table entry. Syntax VirtualDiskEntry Access Not accessible Index virtualDiskNumber Virtual Disk Number Name virtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.1 Description Identifies the instance number of the virtual disk entry.
book.book Page 674 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of the virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online.
book.book Page 675 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskSeverity Syntax Integer Access Read-only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 Description Identifies the size of this virtual disk in megabytes. If the size is 0, the size is smaller than a megabyte.
book.book Page 676 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 677 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskReadPolicy Description Indicates whether the controller's read cache is used when reading from a virtual disk.
book.book Page 678 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskLayout Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24: RAID-60 25: CacheCade Syntax Integer Access Read-only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 679 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Virtual Disk Channel Name virtualDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.16 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Target ID Name virtualDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 680 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskRollUpStatus Description Identifies the severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 681 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskNexusID Description Displays the durable unique ID for the virtual disk. Syntax DisplayString Access Read-only Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk.
book.book Page 682 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Virtual Disk Bad Blocks Detected Name virtualDiskBadBlocksDetected Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.23 Description Indicates if virtual disk has bad blocks. Possible values: 0 - No 1 - Yes 2 - Not Applicable 99 - Unknown Syntax Integer Access Read-only Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 683 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.
book.book Page 684 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Virtual Disk Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.26 Description Indicates disk cache policy of the logical device. Value: 1 - Enabled, 2 - Disabled, 99 - Undetermined Syntax Integer Access Read-only Virtual Disk Associated Fluid Cache Status Name virtualDiskAssociatedFluidCacheStatus Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 685 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskPartitionEntry Description An entry in the Virtual Disk Partition table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax VirtualDiskPartitionEntry Access Not-Accessible Virtual Disk Partition Number Name virtualDiskPartitionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.
book.book Page 686 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name virtualDiskPartitionState Syntax INTEGER Access Read-only Virtual Disk Partition Size Name virtualDiskPartitionSize Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4 Description Size of the Partition in GB Syntax INTEGER Access Read-only Virtual Disk Partition Fluid Cache Status Name virtualDiskPartitionFluidCacheStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.
book.book Page 687 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fluid Cache Table Fluid Cache Table Name fluidCacheTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.4 Description A table of managed FluidCache. The number of entries is related to FluidCache discovered in the system. The maximum number of entries is implementation dependent. NOTE: The properties in this table may not be applicable to all entries.
book.book Page 688 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name fluidCacheName Description The name of the fluidcache in this subsystem as represented in Storage Management. Syntax OCTET STRING Access Read-Only Fluid Cache License State Name fluidCacheLicenseState Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.3 Description License state of the associated fluid cache subsystem.
book.book Page 689 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fluid Cache License Duration Name fluidCacheLicenseDuration Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.6 Description Indicates the duration of the the license validity. Syntax OCTET STRING Access Read-Only Fluid Cache License Capacity Name fluidCacheLicenseCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.
book.book Page 690 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fluid Cache License Vendor Name fluidCacheLicenseVendor Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.10 Description Indicates the license vendor for the fluidcache subsystem. Syntax OCTET STRING Access Read-Only Fluid Cache License Product ID Name fluidCacheLicenseProductId Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.
book.book Page 691 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fluid Cache License Feature ID Name fluidCacheLicenseFeatureID Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.14 Description Indicates the license feature ID of the fluidcache subsystem. Syntax OCTET STRING Access Read-Only Fluid Cache License Feature Description Name fluidCacheLicenseFeatureDescription Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.
book.book Page 692 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fluid Cache Disk Entry Name fluidCacheDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1 Syntax FluidCacheDiskEntry Access Not-Accessible Fluid Cache Disk Number Name fluidCacheDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.1 Description Instance number of the fluidCacheDisk entry.
book.book Page 693 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fluid Cache Disk Backend Device Type Name fluidCacheDiskBackendDeviceType Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.4 Description This displays the type of the backend device beneath the fluid cache disk.
book.book Page 694 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name fluidCacheDiskOperatingMode Description Operating mode of the FluidCache. Values are: • 0 - Writeback mode • 1 - Writethrough mode • 2 - PassThrough mode Syntax INTEGER Access Read-Only Fluid Cache Disk Configured Mode Name fluidCacheDiskConfiguredMode Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.8 Description Configured Mode of the FluidCache.
book.book Page 695 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name fluidCacheDiskStatus Description Severity of the fluid cache disk state. Possible values: • 1: Other • 2: Unknown • 3: OK • 4: Non-critical • 5: Critical • 6 : Non-recoverable Syntax INTEGER Access Read-Only Fluid Cache Pool Table Fluid Cache Pool Table Name fluidCachePoolTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.
book.book Page 696 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Name fluidCachePoolNumber Access Read-Only Fluid Cache Pool Store Count Name fluidCachePoolStoreCount Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.2 Description Number of flash devices that are part of the fluidcache pool. Syntax INTEGER Access Read-Only Fluid Cache Pool UUID Name fluidCachePoolUUID Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.
book.book Page 697 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Fluid Cache Pool High Availability State Name fluidCachePoolHighAvailabilityState Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.6 Description Indicates if the fluidcache pool is operating in high availability mode. Syntax OCTET STRING Access Read-Only Fluid Cache Pool Nexus Name fluidCachePoolNexus Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.
book.book Page 698 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Logical Connection Table This section describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found.
book.book Page 699 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Logical Connection Array Disk Name Name arrayDiskLogicalConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.2 Description Identifies the name of the array disk in the logical connection. Syntax DisplayString Access Read-only Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.
book.book Page 700 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Array Disk Logical Connection Disk Name Name arrayDiskLogicalConnectionDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.6 Description Identifies the name of the disk group to which the array disk belongs. NOTE: This property is currently not supported.
book.book Page 701 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Displays the Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
book.book Page 702 Wednesday, March 6, 2013 12:37 AM FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Displays the durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Displays the current status of object causing the alert, if applicable.
book.book Page 703 Wednesday, March 6, 2013 12:37 AM Change Management Group 24 The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. Inventory Group The following objects describe the fields for inventory information. Inventory Locale Name inventoryLocale Object ID 1.3.6.1.4.1.674.10899.1.1 Description Defines the locale of the system.
book.book Page 704 Wednesday, March 6, 2013 12:37 AM Name inventorySystemID Access Read-only Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Group Table The following object sets up the Device Group Table. Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table.
book.book Page 705 Wednesday, March 6, 2013 12:37 AM Device Component ID Name deviceComponentID Object ID 1.3.6.1.4.1.674.10899.1.5.1.2 Description Defines an optional component ID field for the device. Syntax Integer Access Read-only Device Display String Name deviceDisplayString Object ID 1.3.6.1.4.1.674.10899.1.5.1.3 Description Provides a displayable string that describes the device. Syntax DisplayString Access Read-only Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.
book.book Page 706 Wednesday, March 6, 2013 12:37 AM Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.7 Description Provides additional vendor identification.
book.book Page 707 Wednesday, March 6, 2013 12:37 AM Application Group Table The following object sets up the Application Group Table. Name applicationTable Object ID 1.3.6.1.4.1.674.10899.1.6 Description Defines a table of application information for the system. Syntax SEQUENCE OF ApplicationEntry Access Not accessible Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry.
book.book Page 708 Wednesday, March 6, 2013 12:37 AM Application Component Type Name applicationComponentType Object ID 1.3.6.1.4.1.674.10899.1.6.1.3 Description Identifies the type of application reported. Syntax DisplayString Access Read-only Application Version Name applicationVersion Object ID 1.3.6.1.4.1.674.10899.1.6.1.4 Description Identifies the version of the application.
book.book Page 709 Wednesday, March 6, 2013 12:37 AM Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Operating System Vendor Name operatingSystemVendor Object ID 1.3.6.1.4.1.674.10899.2.1 Description Defines the vendor of the Operating System.
book.book Page 710 Wednesday, March 6, 2013 12:37 AM Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1.3.6.1.4.1.674.10899.2.5 Description Defines the Operating System's Service Pack major version. Syntax DisplayString Access Read-only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1.3.6.1.4.1.674.10899.2.6 Description Defines the Operating System's Service Pack minor version.
book.book Page 711 Wednesday, March 6, 2013 12:37 AM Product ID Display Name Name productIDDisplayName Object ID 1.3.6.1.4.1.674.10899.100.1 Description Defines the display name of the product. Syntax DisplayString Access Read-only Product ID Description Name productIDDescription Object ID 1.3.6.1.4.1.674.10899.100.2 Description Provides a description of the product. Syntax DisplayString Access Read-only Product ID Vendor Name productIDVendor Object ID 1.3.6.1.4.1.674.10899.100.
book.book Page 712 Wednesday, March 6, 2013 12:37 AM Product ID Build Number Name productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5 Description Describes the software build number of the product.
book.book Page 713 Wednesday, March 6, 2013 12:37 AM 25 Dell Remote Access Controller Outof-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB tables define the Dell RAC Out-of-Band group: DRsProductName Name DRsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.
book.book Page 714 Wednesday, March 6, 2013 12:37 AM DRsProductDescription Name DRsProductDescription Object ID 1.3.6.1.4.1.674.10892.2.1.1.3 Description Defines the product description of a chassis management controller. Syntax DellString Access Read-only DRsProductManufacturer Name DRsProductManufacturer Object ID 1.3.6.1.4.1.674.10892.2.1.1.4 Description Defines the product manufacturer of a chassis management controller.
book.book Page 715 Wednesday, March 6, 2013 12:37 AM DRsProductURL Name DrsProductURL Object ID 1.3.6.1.4.1.674.10892.2.1.1.7 Description Defines the out-of-band UI URL of a chassis management controller. Syntax DellString Access Read-only DRsProductChassisAssetTag Name DRsProductChassisAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.8 Description Defines the Asset Tag of the chassis.
book.book Page 716 Wednesday, March 6, 2013 12:37 AM DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.12 Description Defines the asset tag of a system. Syntax DellString Access Read-only DRsProductSystemSlot Name DRsProductSystemSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.
book.book Page 717 Wednesday, March 6, 2013 12:37 AM DRsFirmwareVersion Name DRsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller. Syntax DellString Access Read-only Chassis Status The following MIB tables provide information on Chassis being monitored by the chassis management card. DRsGlobalSystemStatus Name DRsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.
book.book Page 718 Wednesday, March 6, 2013 12:37 AM DRsIOMCurrStatus Name DRsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsKVMCurrStatus Name DRsKVMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.3 Description Defines the iKVM subsystem health status being monitored by the chassis management card.
book.book Page 719 Wednesday, March 6, 2013 12:37 AM DRsPowerCurrStatus Name DRsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsFanCurrStatus Name DRsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card.
book.book Page 720 Wednesday, March 6, 2013 12:37 AM DRsTempCurrStatus Name DRsTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCCurrStatus Name DRsCMCCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.9 Description Defines the CMC health status being monitored by the chassis management card.
book.book Page 721 Wednesday, March 6, 2013 12:37 AM DRsCMAmbientTemperature Name drsCMCAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.11 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Syntax DellTemperatureReading Access Read-only DRsCMProcessorTemperature Name drsCMCProcessorTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.
book.book Page 722 Wednesday, March 6, 2013 12:37 AM DRsIOMPrevStatus Name DRsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.2 Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsKVMPrevStatus Name DRsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card.
book.book Page 723 Wednesday, March 6, 2013 12:37 AM DRsPowerPrevStatus Name DRsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsFanPrevStatus Name DrsFanPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.6 Description Defines the previous fan health status being monitored by the chassis management card.
book.book Page 724 Wednesday, March 6, 2013 12:37 AM DRsTempPrevStatus Name DRsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCPrevStatus Name DRsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.9 Description Defines the CMC health status being monitored by the chassis management card.
book.book Page 725 Wednesday, March 6, 2013 12:37 AM DRsKVMChangeTime Name DRsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only DRsRedChangeTime Name DRsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only DRsPowerChangeTime Name DRsPowerChangeTime Object ID 1.3.
book.book Page 726 Wednesday, March 6, 2013 12:37 AM DRsBladeChangeTime Name DRsBladeChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.7 Description Defines the timestamp of the most recent blade health status change. Syntax TimeTicks Access Read-only DRsTempChangeTime Name DRsTempChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.8 Description Defines the timestamp of the most recent temperature sensor health status change.
book.book Page 727 Wednesday, March 6, 2013 12:37 AM Chassis Power The following MIB tables provide information on the chassis management controller table entry. DRsCMC Power Table Name DRsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible DRsCMC Power Table Entry Name DRsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry.
book.book Page 728 Wednesday, March 6, 2013 12:37 AM DRsCMC PSUTableEntry Name DrsCMCPSUTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.2.1 Description Defines the CMC PSU table entry. Syntax DrsCMCPSUTableEntry Access Not-accessible CMC Power Information The following MIB tables provide information on the chassis power. DRsChassisIndex Name DrsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 729 Wednesday, March 6, 2013 12:37 AM DRsIdlePower Name DRsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3 Description Defines the power (in Watts) required by the chassisinfrastructure, plus the sum of the minimum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only DRsMaxPowerSpecification Name DRsMaxPowerSpecification Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
book.book Page 730 Wednesday, March 6, 2013 12:37 AM DRsKWhCumulative Name DRsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only DRsKWhCumulativeTime Name DRsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset.
book.book Page 731 Wednesday, March 6, 2013 12:37 AM DRsWattsMinUsage Name DRsWattsMinUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10 Description Defines the chassis minimum power usage (in Watts) since last reset. Syntax DellPowerReading Access Read-only DRsWattsMinTime Name DRsWattsMinTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11 Description Defines the timestamp of the most recent chassis minimum power usage.
book.book Page 732 Wednesday, March 6, 2013 12:37 AM DRsWattsReading Name DRsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in Watts) Syntax DellPowerReading Access Read-only DRsAmpsReading Name DRsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in Watts).
book.book Page 733 Wednesday, March 6, 2013 12:37 AM DRsPSUIndex Name DRsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only DRsPSULocation Name DRsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only DRsPSUMonitoringCapable Name DRsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.
book.book Page 734 Wednesday, March 6, 2013 12:37 AM DRsPSUAmpsReading Name DRsPSUAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6 Description Defines the instantaneous PSU Current reading. Syntax DellPowerReading Access Read-only DRsPSUWattsReading Name DrsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU Wattage reading.
book.book Page 735 Wednesday, March 6, 2013 12:37 AM DrsCASSCurrStatus Name DrsCASSCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.2 Description Defines the Current Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSPrevStatus Name DrsCASSPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.3 Description Defines the Previous Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSChangeTime Name DrsCASSChangeTime Object ID 1.3.6.1.4.1.
book.book Page 736 Wednesday, March 6, 2013 12:37 AM Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. DRsAlertSystem Name DRsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax Octet String(SIZE (0..255)) Access Read-only DRsAlertTableIndexOID Name DRsAlertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.2.5000.10.2 Description Alert Index Object Identifier.
book.book Page 737 Wednesday, March 6, 2013 12:37 AM DRsAlertCurrentStatus Name DRsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertPreviousStatus Name DRsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertData Name DRsAlertData Object ID 1.3.6.1.4.1.674.10892.
book.
book.book Page 739 Wednesday, March 6, 2013 12:37 AM Traps 26 The Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event logs. Remote Access Controller (RAC) and Baseboard Management Controller (BMC) can also generate SNMP traps in response to hardware events. This section describes the traps, also known as alerts, generated by the Server Administrator, RAC, and BMC.
book.book Page 740 Wednesday, March 6, 2013 12:37 AM are reserved for use only in traps. When a varbind is created for a trap variable, a zero is appended to the object ID (OID) to create the OID for the varbind. System Variable Name alertSystem Object ID 1.3.6.1.4.1.674.10892.1.5000.10.1 Description Identifies the system generating the alert. Syntax DisplayString (SIZE (0..255)) Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
book.book Page 741 Wednesday, March 6, 2013 12:37 AM Previous Status Variable Name alertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.5 Description Specifies the previous status of the object causing the alert. Syntax DellStatus Data Variable Name alertData Object ID 1.3.6.1.4.1.674.10892.1.5000.10.6 Description Provides Server Administrator-defined data related to the alert. Syntax Octet String (SIZE (0..
book.
book.book Page 743 Wednesday, March 6, 2013 12:37 AM Description Line Item Explanation Date and time of Specifies the date and time that an automatic action: server recovery action was performed, for example: Date and time of action: Fri May 30 23:55:44 2003. Description: Specifies the description of the event that occurred, for example: Description: Chipset Err: Critical Event sensor, front panel NMI / diagnostic interrupt was asserted.
book.
book.
book.book Page 746 Wednesday, March 6, 2013 12:37 AM • Warning — An event that is not necessarily significant, but may indicate a possible future problem, such as crossing a warning threshold. • Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function, such as crossing a failure threshold or a hardware failure. Instrumentation Traps This section describes the traps that are generated by the Instrumentation service of the Server Administrator.
book.book Page 747 Wednesday, March 6, 2013 12:37 AM Miscellaneous Traps Table 27-2 lists Miscellaneous traps that inform you that certain alert systems are up and working. TrapID Description Severity Cause System Up 1001 Server Administrator startup complete Information Server Administrator completed its initialization. Thermal Shutdown 1004 Thermal shutdown protection has been initiated Error This message is generated when a system is configured for thermal shutdown due to an error event.
book.book Page 748 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Host System Reset 1007 User initiated host system Information User requested a host system control action control action to reboot, power off, or power cycle the system or Action requested was: another event such as thermal shutdown protection initiated a power off, operating system shutdown.
book.book Page 749 Wednesday, March 6, 2013 12:37 AM Temperature Probe Traps Temperature probes help protect critical components by alerting the systems management console when temperatures become too high inside a chassis. The temperature probe traps use additional variables: sensor location, chassis location, previous state, and temperature sensor value reported in degrees Celsius.
book.book Page 750 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided. Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover.
book.book Page 751 Wednesday, March 6, 2013 12:37 AM Cooling Device Traps Cooling device traps monitor how well a fan is functioning. TrapID Description Severity Cause Cooling Device Normal 1102 Fan sensor returned to a normal value Information A fan sensor reading on the specified system returned to a valid range Sensor location: threshold.
book.book Page 752 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Error A fan sensor in the specified system detected the failure of one or more fans. The sensor location, chassis location, previous state, and fan sensor value are provided. Error A fan sensor detected an error from which it cannot recover. The sensor location, chassis location, previous state, and fan sensor value are provided.
book.book Page 753 Wednesday, March 6, 2013 12:37 AM Voltage Probe Traps Voltage probes monitor the number of volts across critical components. TrapID Description Severity Cause Voltage Probe Normal 1152 Voltage sensor returned to a normal value Information A voltage sensor in the specified system returned to a valid range Sensor location: after crossing a failure Chassis location: threshold.
book.book Page 754 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Error A voltage sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and voltage sensor value are provided.
book.book Page 755 Wednesday, March 6, 2013 12:37 AM Amperage Probe Traps Amperage probes measure the amount of current (in amperes) that is traversing critical components. TrapID Description Severity Cause Amperage Probe Normal 1202 Current sensor returned to a normal value Information A current sensor on the power supply for the specified system or returned to a valid Current sensor reading is withing range range after crossing a failure threshold.
book.book Page 756 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Amperage Probe Failure 1204 Current sensor detected a failure value Error Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Current sensor value (in Amps): If sensor type is discrete: Discrete current state: A current sensor on the power supply for the specified system exceeded its failure threshold.
book.book Page 757 Wednesday, March 6, 2013 12:37 AM Chassis Intrusion Traps Chassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis.
book.book Page 758 Wednesday, March 6, 2013 12:37 AM Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for example, are so important for preventing damage or disruption of a computer system that a chassis may have extra fans or power supplies installed. Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed.
book.book Page 759 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Warning A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant. The redundancy unit location, chassis location, and previous redundancy state are provided.
book.book Page 760 Wednesday, March 6, 2013 12:37 AM Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis. TrapID Description Severity Cause Power Supply Normal 1352 Power supply returned to normal Information Sensor location: Chassis location: Previous state was: A power supply has been reconnected or replaced.
book.book Page 761 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Error A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, and additional information about the power supply event are provided.
book.book Page 762 Wednesday, March 6, 2013 12:37 AM TrapID Description 1404 Severity Memory device status: Error Memory device location: Possible memory module event cause: Cause A memory device correction rate exceeded an acceptable value, a memory spare bank was activated, or a Uncorrectable Memory Event occurred. The system continues to function normally (except for a Uncorrectable Memory Event). Clear the memory error on Uncorrectable Memory Event.
book.book Page 763 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Warning A fan enclosure has been removed from the specified system. The sensor location and chassis location are provided.
book.book Page 764 Wednesday, March 6, 2013 12:37 AM AC Power Cord Traps The AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord traps provide status and warning information for power cords that are part of an AC power switch, if your system supports AC switching.
book.book Page 765 Wednesday, March 6, 2013 12:37 AM Hardware Log Traps Hardware logs provide hardware status messages to systems management software. On certain systems, the hardware log is implemented as a circular queue. When the log becomes full, the oldest status messages are overwritten when new status messages are logged. On some systems, the log is not circular. When the log becomes full, subsequent hardware status messages are lost.
book.book Page 766 Wednesday, March 6, 2013 12:37 AM TrapID Description Severity Cause Processor Device Status Normal 1602 Processor sensor returned to a normal value Sensor Location: Chassis Location: Information A processor sensor in the specified system transitioned back to a normal state. The sensor location, chassis location, previous state and processor sensor status are provided.
book.book Page 767 Wednesday, March 6, 2013 12:37 AM Pluggable Device Traps Server Administrator monitors the addition and removal of pluggable devices such as memory cards. Device traps provide information about the addition and removal of such devices. TrapID Description Severity Cause Pluggable Device Addition 1651 Device added to system Device Location: Chassis Location: Information A device was added to the specified system.
book.book Page 768 Wednesday, March 6, 2013 12:37 AM Battery Traps Battery traps provide status and warning information for batteries present in a system with a BMC that reports the status of batteries.
book.book Page 769 Wednesday, March 6, 2013 12:37 AM SD Card Device Traps On systems where the BMC reports the status of SD card devices, the SD card device traps provide status and error information. TrapID Description Severity Cause Critical An SD card device sensor in the specified system detected an error. The sensor location, chassis location, previous state and SD card device type are provided. The SD card state is provided if a SD card is present in the SD card device.
book.book Page 770 Wednesday, March 6, 2013 12:37 AM RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section "Traps" on page 689. The trap variables are sent in the order in which they are listed.
book.book Page 771 Wednesday, March 6, 2013 12:37 AM TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1002 alertDrscAuth RAC Minor Error Authenticati on failures during a time period have exceeded a threshold 1003 alertDrscLost ESM 1004 alertDrscFound The RAC is Information Error ESM communicat ing normally with the baseboard management controller (ESM) RAC DRAC recovered III communicati on with ESM.
book.book Page 772 Wednesday, March 6, 2013 12:37 AM TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1006 alertDrscPower The RAC Information Error On has detected a system power state change to powered-on RAC DRAC detected a III system power state change to power-on.
book.book Page 773 Wednesday, March 6, 2013 12:37 AM TrapID Name Description Severity Category Cause 1011 alertDrscTemp The RAC Temperature Critical probe has detected a failure (or critical) value Critical Error RAC DRAC temperature III probe reading exceeded critical threshold. 1012 alertDrscVolt Normal The RAC Information Error voltage has returned to a normal value RAC voltage DRAC probe reading III returns to normal.
book.book Page 774 Wednesday, March 6, 2013 12:37 AM TrapID Name Description Severity 1016 alertDrscSEL Critical The RAC Critical has detected a new event in the System Event Log with Severity: Critical 1017 Category Cause Supporte d by RAC Platform Error RAC All detected a new system event log with critical severity (detailed log info is in drsAlert Message varbind). alertDrscSEL The RAC Major 80 system event percentFull log is 80% full Status RAC All detected system event log is 80% full.
book.book Page 775 Wednesday, March 6, 2013 12:37 AM TrapID Name Description 1020 The RAC Information Error has detected a new event in the System Event Log with Severity: Normal alertDrscSEL Normal Severity Category Cause Supporte d by RAC Platform RAC All detected a new system event log with normal severity (detailed log info is in drsAlert Message varbind).
book.
book.
book.
book.
book.
book.book Page 781 Wednesday, March 6, 2013 12:37 AM Storage Management Alert Reference 27 Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up.
book.book Page 782 Wednesday, March 6, 2013 12:37 AM Viewing Alerts Storage Management generates alerts that are added to the Windows application alert log and to the Server Administrator Alert log. To view these alerts in Server Administrator: 1 Select the System object in the tree view. 2 Select the Logs tab. 3 Select the Alert subtab. You can also view these alerts in the Windows Event Viewer. Every alert consists of the following: • Severity — Shows the severity of alert.
book.book Page 783 Wednesday, March 6, 2013 12:37 AM The alert severity levels are as follows: Table 27-1. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention.
book.book Page 784 Wednesday, March 6, 2013 12:37 AM The Windows SNMP service must be configured to forward the SNMP traps to the target system or application. When forwarding to an application, the application should also be configured to receive the SNMP traps. The IT Assistant application is already configured to receive the SNMP traps generated by Storage Management. See your Windows operating system documentation for information on configuring the operating system to forward SNMP traps.
book.book Page 785 Wednesday, March 6, 2013 12:37 AM Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console. These traps are defined in the Storage Management MIB. These traps correspond to the alerts documented in the “Alert Descriptions and Corrective Actions” section. For more information on the MIB and its structure, as well as a change history of the SNMP traps, see the "Introduction" on page 17 section.
book.
book.book Page 787 Wednesday, March 6, 2013 12:37 AM 28 iDRAC7 MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-MIB.txt) is the MIB supported by the Integrated Dell Remote Access Controller 7 (iDRAC7). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 of a system.
book.book Page 788 Wednesday, March 6, 2013 12:37 AM iDRAC7 Supported SNMP Versions The following table identifies the SNMP version(s) that are supported by iDRAC7 for the given SNMP operations. SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1 and v2c TRAP SNMP v1 iDRAC7 Out-of-Band Group The objects of the Integrated Dell Remote Access Controller (iDRAC) MIB (iDRAC-MIB.txt) are organized into subgroups of the iDRAC7 Out-of-Band Group.
book.book Page 789 Wednesday, March 6, 2013 12:37 AM RAC Short Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access Read-only RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card.
book.book Page 790 Wednesday, March 6, 2013 12:37 AM RAC URL Name racURL Object ID 1.3.6.1.4.1.674.10892.5.1.1.6.0 Description This attribute defines the out-of-band UI URL of a remote access card. Syntax StringType Access Read-only RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.
book.book Page 791 Wednesday, March 6, 2013 12:37 AM Chassis Service Tag Name chassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.0 Description This attribute defines the service tag of the enclosing chassis. Syntax StringType Access Read-only System Information Group The System Information Group objects provide information about the system in which the iDRAC resides. System Fully Qualified Domain Name Name systemFQDN Object ID 1.3.6.1.4.1.674.10892.5.1.3.1.
book.book Page 792 Wednesday, March 6, 2013 12:37 AM Name systemExpressServiceCode Syntax StringType Access Read-only System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description This attribute defines the asset tag of the system. Syntax StringType Access Read-only System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.6.1.4.1.674.10892.5.1.3.5.0 Description This attribute defines the slot number of the blade in the chassis.
book.book Page 793 Wednesday, March 6, 2013 12:37 AM Name systemFormFactor Description This attribute defines the form factor of the system. Syntax SystemFormFactorEnum Access Read-only System Data Center Name Name systemDataCenterName Object ID 1.3.6.1.4.1.674.10892.5.1.3.8.0 Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.
book.book Page 794 Wednesday, March 6, 2013 12:37 AM Name systemRackSlot Description This attribute defines the Rack Slot locator of the system. Syntax StringType Access Read-only System Model Name Name systemModelName Object ID 1.3.6.1.4.1.674.10892.5.1.3.12.0 Description This attribute defines the model name of the system. Syntax StringType Access Read-only Status Group The Status Group objects provide status information about the system and storage.
book.book Page 795 Wednesday, March 6, 2013 12:37 AM Name systemLCDStatus Access Read-only Global Storage Status Name globalStorageStatus Object ID 1.3.6.1.4.1.674.10892.5.2.3.0 Description This attribute defines the overall storage status being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only iDRAC7 Traps The iDRAC7 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC7 Lifecycle Log.
book.book Page 796 Wednesday, March 6, 2013 12:37 AM The trap subgroups, and all the traps within each trap subgroup, are described and listed in sections following the "Trap Variables" section. NOTE: The traps listed in this document can be correlated to specific events that are documented in the Dell Event Message Reference guide. There is 1-to-many relationship between SNMP traps and events in iDRAC7.
book.book Page 797 Wednesday, March 6, 2013 12:37 AM Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.0 Description Service tag of the system. Syntax DisplayString (SIZE (0..16)) Alert System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.5.3.1.5.0 Description Fully qualified domain name of the system. Syntax StringType Alert FQDD Variable Name alertFQDD Object ID 1.3.6.1.4.1.674.10892.5.3.1.5.
book.book Page 798 Wednesday, March 6, 2013 12:37 AM Table 28-1. Amperage Probe Traps TrapID Description Category SubCategory Severity Amperage Informational Amperage Minor Amperage Critical SubCategory Severity System Health Auto Sys Reset Critical Category SubCategory Severity System Health Battery Event Informational System Health Battery Event Minor System Health Battery Event Critical Amperage Probe Normal 2179 Current sensor reading is System within range.
book.book Page 799 Wednesday, March 6, 2013 12:37 AM Table 28-4. Processor Device Status Traps TrapID Description Category SubCategory Severity System Health Processor Informational System Health Processor Minor System Health Processor Critical SubCategory Severity Proc Absent Critical Processor DeviceStatus Normal 2243 Processor device status has returned to normal. ProcessorDeviceStatusWarning 2242 Processor device status has detected a warning.
book.book Page 800 Wednesday, March 6, 2013 12:37 AM Table 28-6. Fan Traps TrapID Description Category SubCategory Severity System Health Fan Event Informational System Health Fan Event Minor System Health Fan Event Critical SubCategory Severity System Health Hardware Config Informational System Health Hardware Config Minor System Health Hardware Config Critical SubCategory Severity System Health Memory Informational Memory device status is System noncritical.
book.book Page 801 Wednesday, March 6, 2013 12:37 AM TrapID Description 2265 Category Memory device status is System critical.
book.book Page 802 Wednesday, March 6, 2013 12:37 AM Table 28-9. NIC Traps TrapID Description Category SubCategory Severity System Health NIC Config Informational System Health NIC Config Minor System Health NIC Config Critical Table 28-10. Operation System ("OS") Event Traps TrapID Description Category SubCategory Severity Network Information 2091 Network information. Network Warning 2090 Network warning. Network Failure 2089 Network failure or critical event.
book.book Page 803 Wednesday, March 6, 2013 12:37 AM TrapID Description Category SubCategory Severity 2418 System Health PCI Device Minor An error was detected for System a PCI device. Health PCI Device Critical A warning event was detected for a PCI device.
book.book Page 804 Wednesday, March 6, 2013 12:37 AM Table 28-12. Physical Disk Traps TrapID Description Category SubCategory Severity Physical Disk Information 2299 Physical disk information. System Health Physical Disk Informational System Health Physical Disk Minor System Health Physical Disk Critical Category SubCategory Severity BIOS POST Critical SubCategory Severity Physical Disk Warning 2298 Physical disk warning. Physical Disk Failure 2297 Physical disk failure. Table 28-13.
book.book Page 805 Wednesday, March 6, 2013 12:37 AM Table 28-15. Power Supply Absent Trap TrapID Description Category SubCategory Severity PSU Absent Critical SubCategory Severity System Health Power Usage Informational System Health Power Usage Minor The system halted System because system power Health exceeds capacity; or the system performance degraded because power draw exceeds the power threshold.
book.book Page 806 Wednesday, March 6, 2013 12:37 AM Table 28-18. Integrated Dual SD Module Traps TrapID Description Category SubCategory Severity Integrated Dual SD ModuleInformation 2211 Integrated Dual SD Module information. System Health IDSDM Media Informational System Health IDSDM Media Minor System Health IDSDM Media Critical Integrated Dual SD ModuleWarning 2210 Integrated Dual SD Module warning. Integrated Dual SD ModuleFailure 2297 Integrated Dual SD Module failure. Table 28-19.
book.book Page 807 Wednesday, March 6, 2013 12:37 AM Table 28-21. Security Event Traps TrapID Description Category SubCategory Severity System Health Security Event Informational Security failure or critical System event. Health Security Event Critical SubCategory Severity System Health Sys Event Log Informational System Health Sys Event Log Minor System Event Log failure System or critical event.
book.book Page 808 Wednesday, March 6, 2013 12:37 AM Table 28-24. Temperature Statistics Traps TrapID Description Category SubCategory Severity Temperature Statistics Warning 2522 Temperature has been System above the warning or Health critical threshold level for a long enough period of time to be considered in a warning state.
book.book Page 809 Wednesday, March 6, 2013 12:37 AM Table 28-27. Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage Informational Voltage Minor Voltage Critical Voltage Probe Normal 2171 Voltage sensor reading is System within range. Health Voltage Probe Warning 2170 Voltage sensor has System detected a warning value. Health Voltage Probe Failure 2169 Voltage sensor has detected a failure value.
book.book Page 810 Wednesday, March 6, 2013 12:37 AM Table 28-28.
book.book Page 811 Wednesday, March 6, 2013 12:37 AM TrapID Description Category SubCategory Severity Storage Storage Enclosr Critical Storage Enclosure Failure 4337 Enclosure failure.
book.book Page 812 Wednesday, March 6, 2013 12:37 AM Table 28-31. Fan Traps TrapID Description Category SubCategory Severity Storage Fan Event Informational Storage Fan Event Minor Storage Fan Event Critical SubCategory Severity Storage Fan Information 4203 Fan information. Storage Fan Warning 4202 Fan warning. Storage Fan Failure 4201 Fan failure. Table 28-32. Physical Disk Traps TrapID Description Category Storage Physical Disk Information 4347 Physical disk information.
book.book Page 813 Wednesday, March 6, 2013 12:37 AM Table 28-34. Storage Management Status Traps TrapID Description Category SubCategory Severity Storage Management Information 4179 Storage Management Storage information. There is no global status change associated with this trap. Storage Informational Storage Minor Storage Critical SubCategory Severity Storage Management Warning 4178 Storage Management has Storage detected a device independent warning condition.
book.book Page 814 Wednesday, March 6, 2013 12:37 AM Table 28-36. Virtual Disk Trap TrapID Description Category SubCategory Severity Virtual Disk Informational Storage Virtual Disk Minor Storage Virtual Disk Critical Storage VirtualDisk Information 4355 Virtual disk information. Storage Storage Virtual Disk Warning 4354 Virtual disk warning. Storage Virtual Disk Failure 4353 Virtual disk failure.
book.book Page 815 Wednesday, March 6, 2013 12:37 AM Table 28-37. Debug Traps TrapID Description Category SubCategory Severity Audit Debug Informational Audit Debug Minor SubCategory Severity Audit DRAC IP Address Informational Category SubCategory Severity Audit Licensing Informational Audit Licensing Minor Audit Licensing Critical Debug Information 8595 Debug authorized. DebugWarning 8594 Debug authorization failed. Table 28-38.
book.book Page 816 Wednesday, March 6, 2013 12:37 AM Configuration event category of the iDRAC7. Configuration traps are traps generated in response to events related to hardware configuration changes and software configuration changes. Table 28-41. Test Trap TrapID Description Category SubCategory Severity Test Trap Event 10395 The iDRAC generated a Configuratio Test Alert test trap event in n response to a user request.
book.
book.
book.book Page 819 Wednesday, March 6, 2013 12:37 AM 29 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib, dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
book.book Page 820 Wednesday, March 6, 2013 12:37 AM Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of StateCapabilities or StateCapabilitiesUnique are integers representing a series of bit definitions. They are NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal value should be converted to hex and the appropriate bits should be parsed from hex.
book.book Page 821 Wednesday, March 6, 2013 12:37 AM Table 29-3. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled. unknown(1) The object’s state is unknown. enabled(2) The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The object is not ready.
book.book Page 822 Wednesday, March 6, 2013 12:37 AM Dell Status Data Types Status data types include DellStatus, DellStatusRedundancy, and DellStatusProbe. Table 29-5. Dell Status Variable Name: DellStatus Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s status is unknown. ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical.
book.book Page 823 Wednesday, March 6, 2013 12:37 AM Table 29-7. Dell Status Probe Variable Name: DellStatusProbe Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The status of the object is unknown. ok(3) The status of the object is OK. nonCriticalUpper(4) The object is at the noncritical upper limit. CriticalUpper(5) The object is at the critical upper limit.
book.book Page 824 Wednesday, March 6, 2013 12:37 AM Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds. uuuuuu is the number of microseconds, and +fff or -fff is the offset from UTC in minutes.
book.book Page 825 Wednesday, March 6, 2013 12:37 AM 30 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
book.book Page 826 Wednesday, March 6, 2013 12:37 AM 1.3.6.1.4.1.674.10892.1.100.8.0 'https://1.2.3.4:1311' = 1.3.6.1.4.1.674.10892.1.100.9.0 = 'en_US' 1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0' 1.3.6.1.4.1.674.10892.1.100.11.0 = 0 1.3.6.1.4.1.674.10892.1.100.12.0 = 1 1.3.6.1.4.1.674.10892.1.100.13.0 = 'Dell Inc.' 1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3 1.
book.book Page 827 Wednesday, March 6, 2013 12:37 AM 1.3.6.1.4.1.674.10892.1.200.10.1.22.1 '\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.23.1 '\02\02\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 '\03\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 '\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 '\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.
book.book Page 828 Wednesday, March 6, 2013 12:37 AM 1.3.6.1.4.1.674.10892.1.300.10.1.9.1 2650' = 'PowerEdge 1.3.6.1.4.1.674.10892.1.300.10.1.10.1 = 'ASSETTAG' 1.3.6.1.4.1.674.10892.1.300.10.1.11.1 = '1234567' 1.3.6.1.4.1.674.10892.1.300.10.1.12.1 = 254 1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 289 1.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 4 1.3.6.1.4.1.674.10892.1.300.10.1.15.1 = 'SERVER01' 1.3.6.1.4.1.674.10892.1.300.10.1.16.1 '20050513095213.000000-360' = 1.3.6.1.4.1.674.10892.1.300.
book.book Page 829 Wednesday, March 6, 2013 12:37 AM 1.3.6.1.4.1.674.10892.1.300.10.1.31.1 = 15 1.3.6.1.4.1.674.10892.1.300.10.1.32.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.33.1 = 27 1.3.6.1.4.1.674.10892.1.300.10.1.34.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.35.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480 1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0 1.3.
book.
book.
book.
book.
book.
book.
book.