with the Service and Diagnostics utility.
Description: Storage Management may not recognize devices that are installed
after Storage Management is already running.
Solution: If Storage Management does not recognize a newly-added device and
this problem has not been corrected with a Global Rescan, then reboot the
system.
• Issue 20: DF120475: Storage Management SNMP traps are not filtered by Server
Administrator.
Description: Server Administrator allows you to filter SNMP traps that you do
not want to receive. To implement SNMP trap filtering, select the "System"
tree-> "Alert Management" tab-> "SNMP Traps" subtab. The "SNMP Traps" subtab
has options for enabling and disabling SNMP traps based on severity or the
component that generates the trap. Even when the SNMP traps are disabled,
Storage Management generates SNMP traps.
Solution: SNMP trap filtering will be provided in a future release of Storage
Management.
• Issue 21: When issuing certain "omconfig storage" CLI commands with "Power
User" privileges, the "Error! User has insufficient privileges to run command:
omconfig" message may be displayed. You must be logged on as an Administrator
to perform these actions.
• Issue 22: Invalid "Format and Check Consistency" options are displayed for
regenerating a virtual disk.
When a physical disk in a virtual disk is rebuilding, the virtual disk changes
to a "Regenerating" state. The Format and Check Consistency operations should
not be performed on a virtual disk that is in a "Regenerating" state. However,
the task drop-down menu for a "Regenerating" RAID 1-concatenated virtual disk
may display the "Format and Check Consistency" options.
• Issue 23: Using the Storage Management Service "Advanced Create VDisk Wizard"
may occasionally result in a vertical scrollbar of less than normal width. If this occurs,
resizing the Server Administrator window causes the vertical scrollbar to be redrawn correctly.
• Issue 24: Using the GUI, if a virtual disk is renamed to a name containing multiple blank
and consecutive spaces, the name is truncated to a single space after "Apply" is clicked.
• Issue 25: When the "Open in a New Window" option is selected in the Storage
Management Service Advanced Create VDisk Wizard, the current page is opened in a new
window, rather than launching the selected option.
• Issue 26: With Chinese or Japanese language browser settings, using the Storage Management
Service Advanced Create VDisk Wizard may occasionally result in text overflowing to the
bottom of the side-by-side blue text boxes.