Read me
* Issue 35: DF552204: On Mozilla Firefox browsers (versions 10, 11 and 12), Server
Administrator fails to launch if IPv6 address used.
This is a known issue. For more information, see
https://bugzilla.mozilla.org/show_bug.cgi?id=633001.
Known Limitations and Workarounds For Storage Management Service
• Issue 1: Fluid Cache Details are not automatically enumerated on SUSE Linux 11 SP2
x86_64 Operating System after system reboot.
Description: Fluid Cache details are not enumerated in CLI or GUI after system reboot.Issue is
applicable only to SUSE Linux 11 SP2 x86_64 Operating system
Solution: To see the Fluid Cache details through CLI or GUI, connect to Fluid cache through CLI
or GUI.
CLI Command to connect to Fluid Cache: omconfig storage fluidcache action=connect
GUI Command to connect to Fluid Cache: Although Fluid Cache details are not enumerated in
GUI after system reboot, Fluid Cache component is enumerated in Storage component tree.
Steps to connect:
1. Click on Fluid Cache component listed under storage tree.
2. Click on “Connect Fluid Cache” option to connect to Fluid Cache.
• Issue 2: DAS Fluid Cache License cannot be applied through DWS Client.
• Issue 3: Fluid Cache Pool does not show the updated value of Cache Count after hot
removing the PCIe SSD which is part of Fluid Cache Pool.
• Issue 4: omconfig fluid cache commands fail with “Operation not supported” error
message
Description: omconfig CLI commands for fluid cache fail with “Operation not supported” error
message
Solution: Connect to Fluid cache through CLI or GUI.
CLI Command to connect to Fluid Cache: omconfig storage fluidcache action=connect
GUI Command to connect to Fluid Cache: Although Fluid Cache details are not enumerated in
GUI after system reboot, Fluid Cache component is enumerated in Storage component tree.
Steps to connect:
1. Click on Fluid Cache component listed under storage tree.
2. Click on “Connect Fluid Cache” option to connect to Fluid Cache.
• Issue 5: omconfig fluid cache command addtocachepool fails with “The requested
operation failed due to an internal system error” message
Description: omconfig fluid cache command addtocachepool fails with “The requested
operation failed due to an internal system error” message
Solution: This PCIeSSD belongs to another cache pool. This device may contain data that was
being cached in that cache pool.
If you are absolutely sure that you want to reuse this PCIeSSD and you don’t want to preserve
any data, then run Full Initialization on the PCIeSSD.Warning! All data will be lost on the PCIeSSD
when Full Initialization is run.
• Issue 6: DF529750: Inconsistent reporting between iDRAC7 and Storage Management
regarding HBA adapter batteries.