Messages Reference Guide

Storage Management Message Reference 71
traps for these alerts use all of the SNMP trap variables. For more information
on SNMP support and the MIB, see the Dell OpenManage SNMP Reference
Guide.
To locate an alert, scroll through the following table to find the alert number
displayed on the Server Administrator Alert tab or search this file for the alert
message text or number. See “Understanding Event Messages” on page 8 for
more information on severity levels.
For more information regarding alert descriptions and the appropriate
corrective actions, see the online help.
Table 3-4. Storage Management Messages
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
2048 Device failed Critical /
Failure / Error
Cause: A storage
component such as
a physical disk or an
enclosure has failed.
The failed component
may have been
identified by the
controller while
performing a task such
as a rescan or a check
consistency.
Action: Replace the
failed component.
You can identify which
disk has failed by
locating the disk that
has a red “X” for its
status. Perform a rescan
after replacing the
failed component.
Clear Alert
Number:
2121
Related
Alert
Number:
2095, 2201,
2203
Local
Response
Agent
(LRA)
Number:
2051, 2061,
2071, 2081,
2091, 2101
754
804
854
904
954
1004
1054
1104
1154
1204