Messages Reference Guide

Storage Management Message Reference 245
2930 Even though
caching was
enabled in
write-back
mode, it is
currently
operating in
write-through
mode.:
FluidCache
Warning To resolve the issue, add
a PCIe SSD to the
cache pool.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1603
2931 Even though
caching was
enabled in
write-back or
write-through
mode, it is
currently
operating in
pass-through
mode.:
FluidCache
Warning To resolve the issue, add
one or more PCIe SSDs
to the cache pool.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1203 -
1503
2932 Caching is no
longer
degraded to
write-through
mode and is
now operating
in write-back
mode.:
FluidCache
Warning No action required. Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1203
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers