Messages Reference Guide

Storage Management Message Reference 237
2702 The following
journal mirror
has
failed.(wwn)
%1 :
FluidCache
Warning No action required. Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1603
2703 There are not
enough journal
mirrors
available to
operate. :
FluidCache
Error To resolve the issue, you
must ensure that there
are at least two journal
mirrors that are
accessible. You must
activate either one or
more failed cache
devices or use the
fldc_restore utility to
rebuild the node.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1604
2704 The cluster ID
in the journal
does not
match the
cluster ID in
the
configuration
file. :
FluidCache
Error Service is required.
Contact Dell Technical
Support.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1604
2705 The journal
could not be
read/written. :
FluidCache
Error Service is required.
Contact Dell Technical
Support.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1604
Table 3-4. Storage Management Messages