Command Line Interface Guide
74 omreport: Viewing System Status Using the Instrumentation Service
• Enclosure Warning
• Enclosure Failure
• Storage Controller Battery Warning
• Storage Controller Battery Failure
• Removable Flash Media Present
• Removable Flash Media Removed
• Removable Flash Media Failure
NOTE: Storage Controller Battery Warning and Storage Controller Battery Failure
events are not available on Blade systems.
NOTE: System Power Probe Warning is not applicable to Blade systems.
omreport system assetinfo or omreport servermodule assetinfo
Use the omreport system assetinfo or omreport servermodule assetinfo
command to see cost of ownership data for the system, such as acquisition,
depreciation, and warranty information. To set any of these fields, use the
omconfig system assetinfo or omconfig servermodule assetinfo command.
For more information, see "omconfig system or servermodule assetinfo:
Editing Cost of Ownership Values" on page 177.
omreport system events or omreport servermodule events
Use the omreport system events or omreport servermodule events command
to view the currently enabled or disabled SNMP traps. This command
displays a summary of each component in the system for which events are
generated. For each component, the report shows which severities are set to
report and which severities are set not to report. Type:
omreport system events
or
omreport servermodule events