Command Line Interface Guide
62 omreport: Viewing System Status Using the Instrumentation Service
omreport chassis pwrmanagement or omreport mainsystem
pwrmanagement
Use the omreport chassis pwrmanagement or omreport mainsystem
pwrmanagement command to view the power budget cap and power
management profiles of the system. The values display either in Watts or
BTU/Hr based on the configuration. Type:
omreport chassis pwrmanagement
or
omreport mainsystem pwrmanagement
NOTE: To maintain consistency across the commands, the output format of this
command has changed. Change the user scripts as applicable.
NOTE: The omreport chassis pwrmanagement or omreport mainsystem
pwrmanagement command is applicable from PowerEdge
yx1x
system onwards
that support Power Management Bus (PMBus) and that have hot-swappable power
supplies and not systems that have a fixed, non-redundant power supply installed.
For each power management profile in the system, values display for the
following fields:
Maximum Performance, Active Power Controller, OS Control, and Custom.
Custom attributes are:
CPU Power and Performance Management, Memory Power and
Performance Management, and Fan Power and Performance Management.