Command Line Interface Guide
omreport: Viewing System Status Using the Instrumentation Service 53
The index parameter specifies a chassis number and is optional. If you do not
specify the index, Server Administrator displays summary chassis information
for each chassis. If you specify the index, Server Administrator displays
summary information for a specific chassis.
NOTE: If iDRAC is installed, Server Administrator displays the LCC version. If BMC
is installed, Server Administrator displays the USC version.
Depending on the system’s configuration, you may notice the following
output:
omreport chassis intrusion
Use the omreport chassis intrusion command to find out whether the cover
of the system is open or not. Server Administrator tracks chassis intrusion
events because intrusions may indicate an attempt to steal a system
component, or to perform unauthorized maintenance on the system. Type:
omreport chassis intrusion
Index : 0
Chassis Name : Main System Chassis
Host Name : WIN-27C02UQFV6L
iDRAC7 Version : 1.00
Chassis Model : PowerEdge R720
Chassis Lock : Present
Chassis Service Tag : 7654321
Express Service Code : 15608862073
Chassis Asset Tag : c