Command Line Interface Guide

280 omconfig storage Commands
omconfig Reset All Temperature Probe Thresholds
Use the following omconfig command syntax to reset the minimum and
maximum warning temperature thresholds back to their default value for all
temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=
resetalltempprobes controller=id enclosure=
<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.
Example Syntax
To reset the thresholds for all temperature probes in enclosure 3 attached to
connector 2 on controller 1:
For SAS controllers:
omconfig storage enclosure action=
resetalltempprobes controller=1 enclosure=2:3
omconfig Blink
Use the following omconfig command to blink the light-emitting diodes
(LEDs) on the enclosure.
Complete Syntax
omconfig storage enclosure action=blink
controller=id enclosure=<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.