Command Line Interface Guide
omconfig storage Commands 225
• For SAS controllers:
omconfig storage pdisk action=assignglobalhotspare
controller=1 pdisk=0:2:3 assign=yes
NOTE: On a SAS controller, the physical disk resides in enclosure 2.
omconfig Rebuild Physical Disk
Use the following omconfig command syntax to rebuild a failed physical disk.
Rebuilding a disk may take several hours. If you need to cancel the rebuild,
use the Cancel Rebuild task. See the Dell OpenManage Online Help for more
information about Rebuild Physical Disk.
Complete Syntax
omconfig storage pdisk action=rebuild controller=
id pdisk=<PDISKID>
where id is the controller ID. The <PDISKID> variable specifies the
physical disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
To rebuild the physical disk 3 on connector 0 of controller 1:
• For SCSI, SATA, and ATA controllers:
omconfig storage pdisk action=rebuild controller=1
pdisk=0:3
• For SAS controllers:
omconfig storage pdisk action=rebuild controller=1
pdisk=0:2:3
NOTE: On a SAS controller, the physical disk resides in enclosure 2.